120 related articles for article (PubMed ID: 24963870)
1. Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion.
Trabelsi O; Malvè M; Mena Tobar A; Doblaré M
Comput Methods Biomech Biomed Engin; 2015; 18(14):1596-605. PubMed ID: 24963870
[TBL] [Abstract][Full Text] [Related]
2. Patient-specific models of human trachea to predict mechanical consequences of endoprosthesis implantation.
Pérez del Palomar A; Trabelsi O; Mena A; López-Villalobos JL; Ginel A; Doblaré M
Philos Trans A Math Phys Eng Sci; 2010 Jun; 368(1921):2881-96. PubMed ID: 20478912
[TBL] [Abstract][Full Text] [Related]
3. The impact of mechanical ventilation on immature airway smooth muscle: functional, structural, histological, and molecular correlates.
Cullen AB; Cooke PH; Driska SP; Wolfson MR; Shaffer TH
Biol Neonate; 2006; 90(1):17-27. PubMed ID: 16534184
[TBL] [Abstract][Full Text] [Related]
4. Montgomery T-tube: anesthetic management.
Agrawal S; Payal YS; Sharma JP; Meher R; Varshney S
J Clin Anesth; 2007 Mar; 19(2):135-7. PubMed ID: 17379127
[TBL] [Abstract][Full Text] [Related]
5. Emergency Airway Management in a Patient with a T-Tube Tracheal Stent.
Robinson AE; Prekker ME; Reardon RF; McHale EK; Raleigh SM; Driver BE
J Emerg Med; 2022 Jun; 62(6):789-792. PubMed ID: 35550842
[TBL] [Abstract][Full Text] [Related]
6. Tracheal smooth muscle responses to upper airway pressure in conscious dogs.
Plowman L; Edwards PH; Lauff DC; Berthon-Jones M; Sullivan CE
J Appl Physiol (1985); 1990 Apr; 68(4):1555-61. PubMed ID: 2189862
[TBL] [Abstract][Full Text] [Related]
7. FSI analysis of a human trachea before and after prosthesis implantation.
Malvè M; Del Palomar AP; Chandra S; López-Villalobos JL; Finol EA; Ginel A; Doblaré M
J Biomech Eng; 2011 Jul; 133(7):071003. PubMed ID: 21823742
[TBL] [Abstract][Full Text] [Related]
8. Computational fluid dynamic modelling of the effect of ventilation mode and tracheal tube position on air flow in the large airways.
Lumb AB; Burns AD; Figueroa Rosette JA; Gradzik KB; Ingham DB; Pourkashanian M
Anaesthesia; 2015 May; 70(5):577-84. PubMed ID: 25581493
[TBL] [Abstract][Full Text] [Related]
9. The effect of a gas leak around the endotracheal tube on the mean tracheal pressure during mechanical ventilation.
Pérez Fontán JJ; Heldt GP; Gregory GA
Am Rev Respir Dis; 1985 Aug; 132(2):339-42. PubMed ID: 4026056
[TBL] [Abstract][Full Text] [Related]
10. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
[TBL] [Abstract][Full Text] [Related]
11. Airway management using laryngeal mask airway in insertion of the Montgomery tracheal tube for subglottic stenosis -A case report-.
Park JS; Kwon YS; Lee S; Yon JH; Kim DW
Korean J Anesthesiol; 2010 Dec; 59 Suppl(Suppl):S33-6. PubMed ID: 21286455
[TBL] [Abstract][Full Text] [Related]
12. Dead-space reduction and tracheal pressure measurements using a coaxial inner tube in an endotracheal tube.
Lethvall S; Søndergaard S; Kárason S; Lundin S; Stenqvist O
Intensive Care Med; 2002 Aug; 28(8):1042-8. PubMed ID: 12185423
[TBL] [Abstract][Full Text] [Related]
13. The Montgomery T-tube: anaesthetic problems and solutions.
Guha A; Mostafa SM; Kendall JB
Br J Anaesth; 2001 Nov; 87(5):787-90. PubMed ID: 11878535
[TBL] [Abstract][Full Text] [Related]
14. Tracheal gas insufflation as a lung-protective strategy: physiologic, histologic, and biochemical markers.
Oliver RE; Rozycki HJ; Greenspan JS; Wolfson MR; Shaffer TH
Pediatr Crit Care Med; 2005 Jan; 6(1):64-9. PubMed ID: 15636662
[TBL] [Abstract][Full Text] [Related]
15. On Studying the Interaction Between Different Stent Models and Rabbit Tracheal Tissue: Numerical, Endoscopic and Histological Comparison.
Chaure J; Serrano C; Fernández-Parra R; Peña E; Lostalé F; De Gregorio MA; Martínez MA; Malvè M
Ann Biomed Eng; 2016 Feb; 44(2):368-81. PubMed ID: 26589598
[TBL] [Abstract][Full Text] [Related]
16. Compensating Artificial Airway Resistance via Active Expiration Assistance.
Wirth S; Seywert L; Spaeth J; Schumann S
Respir Care; 2016 Dec; 61(12):1597-1604. PubMed ID: 27555619
[TBL] [Abstract][Full Text] [Related]
17. Non-linear material models for tracheal smooth muscle tissue.
Sarma PA; Pidaparti RM; Moulik PN; Meiss RA
Biomed Mater Eng; 2003; 13(3):235-45. PubMed ID: 12883173
[TBL] [Abstract][Full Text] [Related]
18. Finite element analysis of the mechanical behavior of preterm lamb tracheal bifurcation during total liquid ventilation.
Bagnoli P; Acocella F; Di Giancamillo M; Fumero R; Costantino ML
J Biomech; 2013 Feb; 46(3):462-9. PubMed ID: 23177086
[TBL] [Abstract][Full Text] [Related]
19. [Unexpected treatable dyspnea caused by intratracheal granuloma in an amyotrophic lateral sclerosis patient with mechanical ventilation].
Ishida S; Kimura F; Hosokawa T; Satoh T; Furutama D; Sugino M
Rinsho Shinkeigaku; 2007 Sep; 47(9):585-8. PubMed ID: 18018617
[TBL] [Abstract][Full Text] [Related]
20. The Montgomery T-tube tracheal stent.
Wahidi MM; Ernst A
Clin Chest Med; 2003 Sep; 24(3):437-43. PubMed ID: 14535218
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]