These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 24965913)

  • 1. Cost-effective usage of membrane oxygenators in extracorporeal membrane oxygenation in infants.
    Özyüksel A; Ersoy C; Akçevin A; Türkoğlu H; Çiçek AE; Kahraman A; Kayhan B; Cantürk E
    Perfusion; 2015 Apr; 30(3):239-42. PubMed ID: 24965913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Extracorporeal membrane oxygenation with a poly-methylpentene oxygenator (Quadrox D). The experience of a single Italian centre in adult patients with refractory cardiogenic shock.
    Formica F; Avalli L; Martino A; Maggioni E; Muratore M; Ferro O; Pesenti A; Paolini G
    ASAIO J; 2008; 54(1):89-94. PubMed ID: 18204321
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early experience with low-prime (99 ml) extracorporeal membrane oxygenation support in children.
    Yamasaki Y; Hayashi T; Nakatani T; Yotsuida H; Nishigaki T; Takahashi Y; Inamori S; Kagisaki K; Hagino H; Ishizaka T; Yagihara T
    ASAIO J; 2006; 52(1):110-4. PubMed ID: 16436900
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation.
    Thiara AP; Hoel TN; Kristiansen F; Karlsen HM; Fiane AE; Svennevig JL
    Perfusion; 2007 Sep; 22(5):323-6. PubMed ID: 18416217
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prolonged extracorporeal membrane oxygenation in sheep with a hollow-fiber oxygenator and a centrifugal pump.
    Palder SB; Shaheen KW; Whittlesey GC; Nowlen TT; Kundu SK; Klein MD
    ASAIO Trans; 1988; 34(3):820-2. PubMed ID: 3196606
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO.
    Mejak B; Giacomuzzi C; Heller E; You X; Ungerleider R; Shen I
    J Extra Corpor Technol; 2007 Jun; 39(2):71-4. PubMed ID: 17672186
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a new hollow fiber silicone membrane oxygenator for ECMO: the recent progress.
    Kawahito S; Motomura T; Glueck J; Nosé Y
    Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):268-74. PubMed ID: 12472408
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Introduction of a new oxygenator including a tight fiber for long-term ECMO in infants.
    Kind K; Reiss N; Knobl HJ; Blanz U; Körfer R
    ASAIO J; 2006; 52(2):217-8. PubMed ID: 16557113
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model.
    Terry B; Gunst G; Melchior R; Wolfe D; Feocco N; Graham S; Searles B; Darling E
    J Extra Corpor Technol; 2005 Sep; 37(3):315-7. PubMed ID: 16350388
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of oxygenator selection on hemodynamic energy indicators under pulsatile and nonpulsatile flow in a neonatal extracorporeal life support model.
    Vasavada R; Khan S; Qiu F; Kunselman A; Undar A
    Artif Organs; 2011 Jun; 35(6):E101-7. PubMed ID: 21623841
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a preprimed microporous hollow-fiber membrane for rapid response neonatal extracorporeal membrane oxygenation.
    Walczak R; Lawson DS; Kaemmer D; McRobb C; McDermott P; Smigla G; Shearer I; Lodge A; Jaggers J
    Perfusion; 2005 Sep; 20(5):269-75. PubMed ID: 16231623
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical evaluation of two different extracorporeal membrane oxygenation systems: a single center report.
    Yu K; Long C; Hei F; Li J; Liu J; Ji B; Gao G; Zhang H; Song Y; Wang W
    Artif Organs; 2011 Jul; 35(7):733-7. PubMed ID: 21375546
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.
    Fujiwara T; Nagaoka E; Watanabe T; Miyagi N; Kitao T; Sakota D; Mamiya T; Shinshi T; Arai H; Takatani S
    Artif Organs; 2013 May; 37(5):447-56. PubMed ID: 23489176
    [TBL] [Abstract][Full Text] [Related]  

  • 14. DIDECMO: a new polymethylpentene oxygenator for pediatric extracorporeal membrane oxygenation.
    Agati S; Ciccarello G; Fachile N; Scappatura RM; Grasso D; Salvo D; Undar A; Mignosa C
    ASAIO J; 2006; 52(5):509-12. PubMed ID: 16966847
    [TBL] [Abstract][Full Text] [Related]  

  • 15. North American neonatal extracorporeal membrane oxygenation (ECMO) devices: 2002 survey results.
    Lawson DS; Walczak R; Lawson AF; Shearer IR; Ing R; Schulman S; Kern F; Jaggers J
    J Extra Corpor Technol; 2004 Mar; 36(1):16-21. PubMed ID: 15095836
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A paediatric ECMO case of plasma leakage through a polymethylpentene oxygenator.
    Gill MC; O'Shaughnessy K; Dittmer J
    Perfusion; 2015 Oct; 30(7):600-3. PubMed ID: 25575705
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemostatic Complications During Neonatal Extracorporeal Membrane Oxygenation: Roller Pump and Centrifugal Pump Driven Circuits.
    Vermeer H; de Jong SF; Koers EJ; Peeters TLM; van der Lee R; de Boode WP; Morshuis WJ
    ASAIO J; 2023 Jun; 69(6):618-624. PubMed ID: 36574471
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.
    Nuszkowski MM; Deutsch N; Jonas RA; Zurakowski D; Montague E; Holt DW
    J Extra Corpor Technol; 2011 Dec; 43(4):207-14. PubMed ID: 22416600
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemolytic and thrombocytopathic characteristics of extracorporeal membrane oxygenation systems at simulated flow rate for neonates.
    Meyer AD; Wiles AA; Rivera O; Wong EC; Freishtat RJ; Rais-Bahrami K; Dalton HJ
    Pediatr Crit Care Med; 2012 Jul; 13(4):e255-61. PubMed ID: 22596067
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.
    Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y
    J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.