These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
337 related articles for article (PubMed ID: 24966176)
21. Fatigue testing median sternotomy closures. Casha AR; Gauci M; Yang L; Saleh M; Kay PH; Cooper GJ Eur J Cardiothorac Surg; 2001 Mar; 19(3):249-53. PubMed ID: 11251261 [TBL] [Abstract][Full Text] [Related]
22. Nitinol thermoreactive clips for secondary sternal closure in cases of noninfective sternal dehiscence. Gucu A; Toktas F; Eris C; Ata Y; Turk T Tex Heart Inst J; 2012; 39(4):513-6. PubMed ID: 22949767 [TBL] [Abstract][Full Text] [Related]
23. Sternal wrapping for the prevention of sternal morbidity in elderly osteoporotic patients undergoing median sternotomy. Kirbas A; Celik S; Gurer O; Yildiz Y; Isik O Tex Heart Inst J; 2011; 38(2):132-6. PubMed ID: 21494519 [TBL] [Abstract][Full Text] [Related]
24. EUROSPINE 2016 FULL PAPER AWARD: Wire cerclage can restore the stability of the thoracic spine after median sternotomy: an in vitro study with entire rib cage specimens. Liebsch C; Graf N; Wilke HJ Eur Spine J; 2017 May; 26(5):1401-1407. PubMed ID: 27639711 [TBL] [Abstract][Full Text] [Related]
25. Randomized, multicenter trial comparing sternotomy closure with rigid plate fixation to wire cerclage. Allen KB; Thourani VH; Naka Y; Grubb KJ; Grehan J; Patel N; Guy TS; Landolfo K; Gerdisch M; Bonnell M; Cohen DJ J Thorac Cardiovasc Surg; 2017 Apr; 153(4):888-896.e1. PubMed ID: 27923485 [TBL] [Abstract][Full Text] [Related]
26. Fatigue testing of three peristernal median sternotomy closure techniques. Wangsgard C; Cohen DJ; Griffin LV J Cardiothorac Surg; 2008 Sep; 3():52. PubMed ID: 18816402 [TBL] [Abstract][Full Text] [Related]
27. A biomechanical study of 4 different sternum closure techniques under different deformation modes. Orhan SN; Ozyazicioglu MH; Colak A Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):750-756. PubMed ID: 28637255 [TBL] [Abstract][Full Text] [Related]
28. Sternal wound dehiscence after median sternotomy: An alternative closure technique. Gallina FT; Melis E; Forcella D; Facciolo F J Card Surg; 2021 Jul; 36(7):2603-2604. PubMed ID: 33783019 [No Abstract] [Full Text] [Related]
29. Double-Wire versus Single-Wire Sternal Closure in Obese Patients: a Randomized Prospective Study. Loladze G; Kuehnel RU; Claus T; Hartrumpf M; Kuepper F; Pohl M; Albes JM Thorac Cardiovasc Surg; 2017 Jun; 65(4):332-337. PubMed ID: 27088193 [No Abstract] [Full Text] [Related]
30. Migrated sternal wire into the right ventricle: case report in cardiothoracic surgery. Levisman J; Shemin RJ; Robertson JM; Pelikan P; Karlsberg RP J Card Surg; 2010 Mar; 25(2):161-2. PubMed ID: 20002234 [TBL] [Abstract][Full Text] [Related]
31. Prophylactic sternal plating with pectoralis advancement flaps after sternotomy in patients with a history of chest irradiation. Neaman KC; Blount AL; Kim JA; Renucci JD; Hooker RL Interact Cardiovasc Thorac Surg; 2011 Mar; 12(3):355-8. PubMed ID: 21138917 [TBL] [Abstract][Full Text] [Related]
32. Practice Patterns in Sternal Closure and Evaluation of Adoption of a Novel Sternal Closure Device. Yost G; Marten T; Plott J; Haft JW Innovations (Phila); 2024; 19(3):283-289. PubMed ID: 38721856 [TBL] [Abstract][Full Text] [Related]
33. Wandering wires: frequency of sternal wire abnormalities in patients with sternal dehiscence. Boiselle PM; Mansilla AV; Fisher MS; McLoud TC AJR Am J Roentgenol; 1999 Sep; 173(3):777-80. PubMed ID: 10470922 [TBL] [Abstract][Full Text] [Related]
34. A modified parasternal wire technique for prevention and treatment of sternal dehiscence. Sharma R; Puri D; Panigrahi BP; Virdi IS Ann Thorac Surg; 2004 Jan; 77(1):210-3. PubMed ID: 14726063 [TBL] [Abstract][Full Text] [Related]
35. Sternal weave in high-risk patients to prevent noninfective sternal dehiscence. Narang S; Banerjee A; Satsangi DK; Geelani MA Asian Cardiovasc Thorac Ann; 2009 Apr; 17(2):167-70. PubMed ID: 19592548 [TBL] [Abstract][Full Text] [Related]
36. Analysis of the sternum for sternal closure with bioabsorbable sternal pins. Kawamura M; Masai T; Matsue H; Yoshikawa Y; Sawa Y Asian Cardiovasc Thorac Ann; 2013 Jun; 21(3):331-4. PubMed ID: 24570501 [TBL] [Abstract][Full Text] [Related]
37. Crossed wiring closure technique for bilateral transverse thoracosternotomy is associated with less sternal dehiscence after bilateral sequential lung transplantation. Koster TD; Ramjankhan FZ; van de Graaf EA; Luijk B; van Kessel DA; Meijer RC; Kwakkel-van Erp JM J Thorac Cardiovasc Surg; 2013 Oct; 146(4):901-5. PubMed ID: 23764413 [TBL] [Abstract][Full Text] [Related]
38. Sternal closure with absorbable pins and cords in general thoracic surgery. Kawashima M; Sano A; Tanaka M Surg Today; 2015 Jul; 45(7):929-31. PubMed ID: 25432301 [TBL] [Abstract][Full Text] [Related]
39. Complications in cardiac surgery: An analysis of factors contributing to sternal dehiscence in patients who underwent surgery between 2010 and 2014 and a comparison with the 1990-2009 cohort. Listewnik MJ; Jędrzejczak T; Majer K; Szylińska A; Mikołajczyk A; Mokrzycki K; Górka E; Brykczyński M Adv Clin Exp Med; 2019 Jul; 28(7):913-922. PubMed ID: 30993919 [TBL] [Abstract][Full Text] [Related]
40. Sternal closure with rigid plate fixation versus wire closure: a randomized controlled multicenter trial. Raman J; Lehmann S; Zehr K; De Guzman BJ; Aklog L; Garrett HE; MacMahon H; Hatcher BM; Wong MS Ann Thorac Surg; 2012 Dec; 94(6):1854-61. PubMed ID: 23103010 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]