BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 24986441)

  • 21. [The value of HRCT in predicting cerebrospinal fluid gusher during cochlear implantation].
    Liu Z; Lin X; Huang H; Dong G; Wu P
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2024 May; 38(5):421-425. PubMed ID: 38686481
    [No Abstract]   [Full Text] [Related]  

  • 22. Influence of an intraoperative perilymph gusher on cochlear implant performance in children with labyrinthine malformations.
    Adunka OF; Teagle HF; Zdanski CJ; Buchman CA
    Otol Neurotol; 2012 Dec; 33(9):1489-96. PubMed ID: 22996156
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Management and control of gusher during cochlear implant surgery.
    Daneshi A; Farhadi M; Emamjomeh H; Hasanzadeh S
    Adv Otorhinolaryngol; 2000; 57():120-2. PubMed ID: 11892123
    [No Abstract]   [Full Text] [Related]  

  • 24. CSF Gusher in Cochlear Implant Surgery-does it affect surgical outcomes?
    Vashist S; Singh S
    Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Jun; 133 Suppl 1():S21-4. PubMed ID: 27256962
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Congenital cerebrospinal fluid pressure labyrinth].
    Michel O; Breunsbach J; Matthias R
    HNO; 1991 Dec; 39(12):486-90. PubMed ID: 1794964
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Novel Computed Tomography Findings Suggestive of Perilymph Gusher.
    Varadarajan VV; DeJesus RO; Antonelli PJ
    Otol Neurotol; 2018 Sep; 39(8):1066-1069. PubMed ID: 30113567
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cochlear implant and inner ear malformation. Proposal for an hyperosmolar therapy at surgery.
    Loundon N; Leboulanger N; Maillet J; Riggouzzo A; Richard P; Marlin S; Garabedian EN
    Int J Pediatr Otorhinolaryngol; 2008 Apr; 72(4):541-7. PubMed ID: 18282614
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Preoperative radiologic evaluation in cochlear implantation.
    Nikolopoulos TP; O'Donoghue GM; Robinson KL; Holland IM; Ludman C; Gibbin KP
    Am J Otol; 1997 Nov; 18(6 Suppl):S73-4. PubMed ID: 9391606
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Cochlear implant in patients with congenital malformation of inner ear].
    Han DY; Wu WM; Xi X; Huang DL; Yang WY
    Zhonghua Er Bi Yan Hou Ke Za Zhi; 2004 Feb; 39(2):85-8. PubMed ID: 15195589
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intraoperative seizure and cerebrospinal fluid leak during adult cochlear implant surgery.
    Musser AB; Golub JS; Samy RN; Phero JC
    Cochlear Implants Int; 2016; 17(2):116-9. PubMed ID: 26843205
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Cochlear implantation in children with inner ear malformation and postoperative performance].
    Ishida K; Makoto S; Iida M; Takahashi M; Naito A; Kitano Y; Koga K
    Nihon Jibiinkoka Gakkai Kaiho; 1999 Dec; 102(12):1300-10. PubMed ID: 10655719
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery.
    Stjernholm C
    Acta Radiol Suppl; 2003 Jul; 430():2-15. PubMed ID: 12834396
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Why did we encounter gusher in a stapes surgery case? Was it enlarged medial aperture of the cochlear aqueduct?
    Satar B; Genc H; Meral SC
    Surg Radiol Anat; 2021 Feb; 43(2):225-229. PubMed ID: 33111218
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Radiologically assisted navigation in cochlear implantation for X-linked deafness malformation.
    Aschendorff A; Maier W; Jaekel K; Wesarg T; Arndt S; Laszig R; Voss P; Metzger M; Schulze D
    Cochlear Implants Int; 2009; 10 Suppl 1():14-8. PubMed ID: 19142886
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Novel Surgical Technique for the Management of Cerebrospinal Fluid Gusher Encountered During Cochlear Implantation.
    Tolisano AM; Wick CC; Kutz JW
    Otol Neurotol; 2020 Oct; 41(9):e1177. PubMed ID: 32925868
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Utility of intraoperative computed tomography for cochlear implantation in patients with difficult anatomy.
    Kim CS; Maxfield AZ; Foyt D; Rapoport RJ
    Cochlear Implants Int; 2018 May; 19(3):170-179. PubMed ID: 29188758
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Complications of pediatric auditory brain stem implantation via retrosigmoid approach.
    Bayazit YA; Abaday A; Dogulu F; Göksu N
    ORL J Otorhinolaryngol Relat Spec; 2011; 73(2):72-5. PubMed ID: 21273799
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surgical considerations regarding cochlear implantation in the congenitally malformed cochlea.
    Ito J; Sakota T; Kato H; Hazama M; Enomoto M
    Otolaryngol Head Neck Surg; 1999 Oct; 121(4):495-8. PubMed ID: 10504611
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The unilateral stapes gusher.
    Rebol J
    Wien Klin Wochenschr; 2004; 116 Suppl 2():90-2. PubMed ID: 15506322
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The common cavity vs incomplete partition type I conundrum: Decision making and management with the cochlear implant form electrode.
    Gaur SK; Dutt SN; Kumar A
    Cochlear Implants Int; 2019 May; 20(3):158-163. PubMed ID: 30810515
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.