BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

383 related articles for article (PubMed ID: 24989384)

  • 1. Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: a feasibility study.
    Regmi R; Lovelock DM; Hunt M; Zhang P; Pham H; Xiong J; Yorke ED; Goodman KA; Rimner A; Mostafavi H; Mageras GS
    Med Phys; 2014 Jul; 41(7):071906. PubMed ID: 24989384
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated target tracking in kilovoltage images using dynamic templates of fiducial marker clusters.
    Campbell WG; Miften M; Jones BL
    Med Phys; 2017 Feb; 44(2):364-374. PubMed ID: 28035655
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust automatic segmentation of multiple implanted cylindrical gold fiducial markers in cone-beam CT projections.
    Fledelius W; Worm E; Elstrøm UV; Petersen JB; Grau C; Høyer M; Poulsen PR
    Med Phys; 2011 Dec; 38(12):6351-61. PubMed ID: 22149818
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold.
    Hazelaar C; Dahele M; Mostafavi H; van der Weide L; Slotman B; Verbakel W
    Phys Med Biol; 2018 May; 63(11):115005. PubMed ID: 29714710
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A deep learning framework for automatic detection of arbitrarily shaped fiducial markers in intrafraction fluoroscopic images.
    Mylonas A; Keall PJ; Booth JT; Shieh CC; Eade T; Poulsen PR; Nguyen DT
    Med Phys; 2019 May; 46(5):2286-2297. PubMed ID: 30929254
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model.
    Zhang Q; Hu YC; Liu F; Goodman K; Rosenzweig KE; Mageras GS
    Med Phys; 2010 Jun; 37(6):2901-9. PubMed ID: 20632601
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.
    Hamming NM; Daly MJ; Irish JC; Siewerdsen JH
    Med Phys; 2009 May; 36(5):1800-12. PubMed ID: 19544799
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Markerless tracking of small lung tumors for stereotactic radiotherapy.
    van Sörnsen de Koste JR; Dahele M; Mostafavi H; Sloutsky A; Senan S; Slotman BJ; Verbakel WF
    Med Phys; 2015 Apr; 42(4):1640-52. PubMed ID: 25832054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An algorithm to extract three-dimensional motion by marker tracking in the kV projections from an on-board imager: four-dimensional cone-beam CT and tumor tracking implications.
    Ali I; Alsbou N; Herman T; Ahmad S
    J Appl Clin Med Phys; 2011 Feb; 12(2):3407. PubMed ID: 21587189
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fully automatic segmentation of arbitrarily shaped fiducial markers in cone-beam CT projections.
    Bertholet J; Wan H; Toftegaard J; Schmidt ML; Chotard F; Parikh PJ; Poulsen PR
    Phys Med Biol; 2017 Feb; 62(4):1327-1341. PubMed ID: 28114115
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs.
    Slagmolen P; Hermans J; Maes F; Budiharto T; Haustermans K; van den Heuvel F
    Med Phys; 2010 Apr; 37(4):1554-64. PubMed ID: 20443476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intrafraction 4D-cone beam CT acquired during volumetric arc radiotherapy delivery: kV parameter optimization and 4D motion accuracy for lung stereotactic body radiotherapy (SBRT) patients.
    Liang J; Lack D; Zhou J; Liu Q; Grills I; Yan D
    J Appl Clin Med Phys; 2019 Dec; 20(12):10-24. PubMed ID: 31675150
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections.
    Poulsen PR; Fledelius W; Keall PJ; Weiss E; Lu J; Brackbill E; Hugo GD
    Med Phys; 2011 Apr; 38(4):2151-6. PubMed ID: 21626948
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers.
    Cui Y; Dy JG; Sharp GC; Alexander B; Jiang SB
    Phys Med Biol; 2007 Oct; 52(20):6229-42. PubMed ID: 17921582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and validation of a MV/kV imaging-based markerless tracking system for assessing real-time lung tumor motion.
    Zhang P; Hunt M; Telles AB; Pham H; Lovelock M; Yorke E; Li G; Happersett L; Rimner A; Mageras G
    Med Phys; 2018 Dec; 45(12):5555-5563. PubMed ID: 30362124
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of a novel liquid fiducial marker for multimodal image guidance in stereotactic body radiotherapy of prostate cancer.
    De Roover R; Crijns W; Poels K; Peeters R; Draulans C; Haustermans K; Depuydt T
    Med Phys; 2018 May; 45(5):2205-2217. PubMed ID: 29537613
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enhancing the target visibility with synthetic target specific digitally reconstructed radiograph for intrafraction motion monitoring: A proof-of-concept study.
    Fu Y; Fan Q; Cai W; Li F; He X; Cuaron J; Cervino L; Moran JM; Li T; Li X
    Med Phys; 2023 Dec; 50(12):7791-7805. PubMed ID: 37399367
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic tracking of implanted fiducial markers in cone beam CT projection images.
    Marchant TE; Skalski A; Matuszewski BJ
    Med Phys; 2012 Mar; 39(3):1322-34. PubMed ID: 22380365
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of tumor localization in respiration motion-corrected cone-beam CT: prospective study in lung.
    Dzyubak O; Kincaid R; Hertanto A; Hu YC; Pham H; Rimner A; Yorke E; Zhang Q; Mageras GS
    Med Phys; 2014 Oct; 41(10):101918. PubMed ID: 25281970
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-time automatic fiducial marker tracking in low contrast cine-MV images.
    Lin WY; Lin SF; Yang SC; Liou SC; Nath R; Liu W
    Med Phys; 2013 Jan; 40(1):011715. PubMed ID: 23298085
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.