BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 24989406)

  • 1. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout.
    Ren S; Yang Y; Cherry SR
    Med Phys; 2014 Jul; 41(7):072503. PubMed ID: 24989406
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of a high-resolution depth encoding PET detector using barium sulfate reflector.
    Kuang Z; Wang X; Li C; Deng X; Feng K; Hu Z; Fu X; Ren N; Zhang X; Zheng Y; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2017 Jul; 62(15):5945-5958. PubMed ID: 28682792
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-Resolution Depth-Encoding PET Detector Module with Prismatoid Light-Guide Array.
    LaBella A; Cao X; Petersen E; Lubinsky R; Biegon A; Zhao W; Goldan AH
    J Nucl Med; 2020 Oct; 61(10):1528-1533. PubMed ID: 32111684
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance comparison of dual-ended readout depth-encoding PET detectors based on BGO and LYSO crystals.
    Du J; Ariño-Estrada G; Bai X; Cherry SR
    Phys Med Biol; 2020 Nov; 65(23):. PubMed ID: 33086214
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Depth of interaction calibration for PET detectors with dual-ended readout by PSAPDs.
    Yang Y; Qi J; Wu Y; St James S; Farrell R; Dokhale PA; Shah KS; Cherry SR
    Phys Med Biol; 2009 Jan; 54(2):433-45. PubMed ID: 19098356
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultra-high-resolution depth-encoding small animal PET detectors: Using GAGG and LYSO crystal arrays.
    Niu M; Liu Z; Kuang Z; Wang X; Ren N; Sang Z; Wu S; Cong L; Sun T; Hu Z; Yang Y
    Med Phys; 2022 May; 49(5):3006-3020. PubMed ID: 35301730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A prototype PET scanner with DOI-encoding detectors.
    Yang Y; Wu Y; Qi J; St James S; Du H; Dokhale PA; Shah KS; Farrell R; Cherry SR
    J Nucl Med; 2008 Jul; 49(7):1132-40. PubMed ID: 18552140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes.
    Yang Y; Dokhale PA; Silverman RW; Shah KS; McClish MA; Farrell R; Entine G; Cherry SR
    Phys Med Biol; 2006 May; 51(9):2131-42. PubMed ID: 16625031
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Tapered LSO arrays for small animal PET.
    Yang Y; James SS; Wu Y; Du H; Qi J; Farrell R; Dokhale PA; Shah KS; Vaigneur K; Cherry SR
    Phys Med Biol; 2011 Jan; 56(1):139-53. PubMed ID: 21119228
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Depth-of-interaction study of a dual-readout detector based on TOFPET2 application-specific integrated circuit.
    Li M; Abbaszadeh S
    Phys Med Biol; 2019 Sep; 64(17):175008. PubMed ID: 31382253
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Crystal surface and reflector optimization for the SiPM-based dual-ended readout TOF-DOI PET detector.
    Kang HG; Yamaya T; Han YB; Song SH; Ko GB; Lee JS; Hong SJ
    Biomed Phys Eng Express; 2020 Nov; 6(6):. PubMed ID: 34035192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical note: Comparison of arithmetic mean and energy-weighted mean flood histogram generation methods for dual-ended readout positron emission tomography detectors.
    Cong L; Kuang Z; Sang Z; Wang X; Niu M; Yang Y
    Med Phys; 2022 Jul; 49(7):4455-4465. PubMed ID: 35567406
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays.
    James SS; Yang Y; Wu Y; Farrell R; Dokhale P; Shah KS; Cherry SR
    Phys Med Biol; 2009 Jul; 54(14):4605-19. PubMed ID: 19567945
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
    Habte F; Foudray AM; Olcott PD; Levin CS
    Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of dual-ended readout GAGG-based DOI-PET detectors with different surface treatments.
    Choghadi MA; Huang SC; Shimazoe K; Takahashi H
    Med Phys; 2021 Jul; 48(7):3470-3478. PubMed ID: 33826779
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M; Park H; Lee S; Ko GB; Lee JS
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
    Son JW; Lee MS; Lee JS
    Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance evaluation of dual-ended readout PET detectors based on BGO arrays with different reflector arrangements.
    Du J; Wang Q; Liu CC; Qi J; Cherry SR
    Phys Med Biol; 2021 Oct; 66(21):. PubMed ID: 34607324
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.