254 related articles for article (PubMed ID: 24989849)
1. Bone SPECT image reconstruction using deconvolution and wavelet transformation: development, performance assessment and comparison in phantom and patient study with standard OSEM and resolution recovery algorithm.
Ptáček J; Henzlová L; Koranda P
Phys Med; 2014 Nov; 30(7):858-64. PubMed ID: 24989849
[TBL] [Abstract][Full Text] [Related]
2. A novel partial volume effects correction technique integrating deconvolution associated with denoising within an iterative PET image reconstruction.
Merlin T; Visvikis D; Fernandez P; Lamare F
Med Phys; 2015 Feb; 42(2):804-19. PubMed ID: 25652494
[TBL] [Abstract][Full Text] [Related]
3. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
4. Performance of a SPECT collimator-detector response reconstruction algorithm: phantom studies and validation in inflammation clinical studies.
Arosio M; Pasquali C; Crivellaro C; De Ponti E; Morzenti S; Guerra L; Crespi A; Messa C
Q J Nucl Med Mol Imaging; 2011 Dec; 55(6):671-9. PubMed ID: 21285924
[TBL] [Abstract][Full Text] [Related]
5. Joint compensation of motion and partial volume effects by iterative deconvolution incorporating wavelet-based denoising in oncologic PET/CT imaging.
Rezaei S; Ghafarian P; Jha AK; Rahmim A; Sarkar S; Ay MR
Phys Med; 2019 Dec; 68():52-60. PubMed ID: 31743884
[TBL] [Abstract][Full Text] [Related]
6. Iterative image-domain decomposition for dual-energy CT.
Niu T; Dong X; Petrongolo M; Zhu L
Med Phys; 2014 Apr; 41(4):041901. PubMed ID: 24694132
[TBL] [Abstract][Full Text] [Related]
7. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
Dong X; Niu T; Zhu L
Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
[TBL] [Abstract][Full Text] [Related]
8. Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.
Okuda K; Nakajima K; Yamada M; Wakabayashi H; Ichikawa H; Arai H; Matsuo S; Taki J; Hashimoto M; Kinuya S
Ann Nucl Med; 2014 Jan; 28(1):60-8. PubMed ID: 24214735
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of Penalized-Likelihood Estimation Reconstruction on a Digital Time-of-Flight PET/CT Scanner for
Lindström E; Sundin A; Trampal C; Lindsjö L; Ilan E; Danfors T; Antoni G; Sörensen J; Lubberink M
J Nucl Med; 2018 Jul; 59(7):1152-1158. PubMed ID: 29449445
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous 99mTc-MDP/123I-MIBG tumor imaging using SPECT-CT: phantom and constructed patient studies.
Rakvongthai Y; El Fakhri G; Lim R; Bonab AA; Ouyang J
Med Phys; 2013 Oct; 40(10):102506. PubMed ID: 24089927
[TBL] [Abstract][Full Text] [Related]
11. A practical way to improve contrast-to-noise ratio and quantitation for statistical-based iterative reconstruction in whole-body PET imaging.
Fin L; Bailly P; Daouk J; Meyer ME
Med Phys; 2009 Jul; 36(7):3072-9. PubMed ID: 19673206
[TBL] [Abstract][Full Text] [Related]
12. Improvement in PET/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters.
Akamatsu G; Ishikawa K; Mitsumoto K; Taniguchi T; Ohya N; Baba S; Abe K; Sasaki M
J Nucl Med; 2012 Nov; 53(11):1716-22. PubMed ID: 22952340
[TBL] [Abstract][Full Text] [Related]
13. Comparison of advanced iterative reconstruction methods for SPECT/CT.
Knoll P; Kotalova D; Köchle G; Kuzelka I; Minear G; Mirzaei S; Sámal M; Zadrazil L; Bergmann H
Z Med Phys; 2012 Feb; 22(1):58-69. PubMed ID: 21723716
[TBL] [Abstract][Full Text] [Related]
14. Improvement of image quality in PET using post-reconstruction hybrid spatial-frequency domain filtering.
Arabi H; Zaidi H
Phys Med Biol; 2018 Oct; 63(21):215010. PubMed ID: 30272565
[TBL] [Abstract][Full Text] [Related]
15. Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment.
Riddell C; Carson RE; Carrasquillo JA; Libutti SK; Danforth DN; Whatley M; Bacharach SL
J Nucl Med; 2001 Sep; 42(9):1316-23. PubMed ID: 11535719
[TBL] [Abstract][Full Text] [Related]
16. Using deconvolution to improve PET spatial resolution in OSEM iterative reconstruction.
Rizzo G; Castiglioni I; Russo G; Tana MG; Dell'Acqua F; Gilardi MC; Fazio F; Cerutti S
Methods Inf Med; 2007; 46(2):231-5. PubMed ID: 17347762
[TBL] [Abstract][Full Text] [Related]
17. Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM).
Cheng JK; Matthews J; Sossi V; Anton-Rodriguez J; Salomon A; Boellaard R
Phys Med Biol; 2017 Aug; 62(16):6666-6687. PubMed ID: 28644152
[TBL] [Abstract][Full Text] [Related]
18. PET based volume segmentation with emphasis on the iterative TrueX algorithm.
Knäusl B; Hirtl A; Dobrozemsky G; Bergmann H; Kletter K; Dudczak R; Georg D
Z Med Phys; 2012 Feb; 22(1):29-39. PubMed ID: 21251804
[TBL] [Abstract][Full Text] [Related]
19. The edge artifact in the point-spread function-based PET reconstruction at different sphere-to-background ratios of radioactivity.
Kidera D; Kihara K; Akamatsu G; Mikasa S; Taniguchi T; Tsutsui Y; Takeshita T; Maebatake A; Miwa K; Sasaki M
Ann Nucl Med; 2016 Feb; 30(2):97-103. PubMed ID: 26531181
[TBL] [Abstract][Full Text] [Related]
20. Clinical evaluation of reducing acquisition time on single-photon emission computed tomography image quality using proprietary resolution recovery software.
Aldridge MD; Waddington WW; Dickson JC; Prakash V; Ell PJ; Bomanji JB
Nucl Med Commun; 2013 Nov; 34(11):1116-23. PubMed ID: 24056385
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]