These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 24990451)

  • 1. Clinical significance of conduction disturbances after aortic valve intervention: current evidence.
    Martinez-Selles M; Bramlage P; Thoenes M; Schymik G
    Clin Res Cardiol; 2015 Jan; 104(1):1-12. PubMed ID: 24990451
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.
    Petronio AS; Sinning JM; Van Mieghem N; Zucchelli G; Nickenig G; Bekeredjian R; Bosmans J; Bedogni F; Branny M; Stangl K; Kovac J; Schiltgen M; Kraus S; de Jaegere P
    JACC Cardiovasc Interv; 2015 May; 8(6):837-846. PubMed ID: 25999108
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Baseline HV-interval predicts complete AV-block secondary to transcatheter aortic valve implantation.
    Shin DI; Merx MW; Meyer C; Kirmanoglou K; Hellhammer K; Ohlig J; Katsani D; Zeus T; Westenfeld R; Eickholt C; Linke A; Kelm M
    Acta Cardiol; 2015 Oct; 70(5):574-80. PubMed ID: 26567817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conduction disorders in the setting of transcatheter aortic valve implantation: a clinical perspective.
    Fraccaro C; Napodano M; Tarantini G
    Catheter Cardiovasc Interv; 2013 Jun; 81(7):1217-23. PubMed ID: 23456893
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry.
    Nazif TM; Dizon JM; Hahn RT; Xu K; Babaliaros V; Douglas PS; El-Chami MF; Herrmann HC; Mack M; Makkar RR; Miller DC; Pichard A; Tuzcu EM; Szeto WY; Webb JG; Moses JW; Smith CR; Williams MR; Leon MB; Kodali SK;
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):60-9. PubMed ID: 25616819
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Steroid therapy and conduction disturbances after transcatheter aortic valve implantation.
    Havakuk O; Konigstein M; Ben Assa E; Arbel Y; Abramowitz Y; Halkin A; Bazan S; Shmilovich H; Keren G; Finkelstein A; Banai S
    Cardiovasc Ther; 2016 Oct; 34(5):325-9. PubMed ID: 27273567
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Managing heart block after transcatheter aortic valve implantation: from monitoring to device selection and pacemaker indications.
    Urena M; Rodés-Cabau J
    EuroIntervention; 2015 Sep; 11 Suppl W():W101-5. PubMed ID: 26384171
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of permanent pacemaker on mortality after transcatheter aortic valve replacement.
    Engborg J; Riechel-Sarup C; Gerke O; Mickley H; Sandgaard NC; Nissen H; Diederichsen AC
    Scand Cardiovasc J; 2017 Feb; 51(1):40-46. PubMed ID: 27624406
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ongoing requirement for pacing post-transcatheter aortic valve implantation and surgical aortic valve replacement.
    Simms AD; Hogarth AJ; Hudson EA; Worsnop VL; Blackman DJ; O'Regan DJ; Tayebjee MH
    Interact Cardiovasc Thorac Surg; 2013 Aug; 17(2):328-33. PubMed ID: 23620339
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Incidence and predictors of permanent pacemaker implantation following transcatheter aortic valve implantation: analysis from the German transcatheter aortic valve interventions registry.
    Ledwoch J; Franke J; Gerckens U; Kuck KH; Linke A; Nickenig G; Krülls-Münch J; Vöhringer M; Hambrecht R; Erbel R; Richardt G; Horack M; Zahn R; Senges J; Sievert H;
    Catheter Cardiovasc Interv; 2013 Oct; 82(4):E569-77. PubMed ID: 23475694
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation: The Critical Role of Valve Implantation Height.
    De Torres-Alba F; Kaleschke G; Diller GP; Vormbrock J; Orwat S; Radke R; Reinke F; Fischer D; Reinecke H; Baumgartner H
    JACC Cardiovasc Interv; 2016 Apr; 9(8):805-813. PubMed ID: 27017367
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis.
    Coti I; Schukro C; Drevinja F; Haberl T; Kaider A; Kocher A; Laufer G; Andreas M
    J Thorac Cardiovasc Surg; 2021 Sep; 162(3):803-811. PubMed ID: 32204909
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conduction dynamics after transcatheter aortic valve implantation and implications for permanent pacemaker implantation and early discharge: the CONDUCT-study.
    van Gils L; Baart S; Kroon H; Rahhab Z; El Faquir N; Rodriguez Olivares R; Aga Y; Maugenest AM; Theuns DA; Boersma E; Szili Torok T; De Jaegere PP; Van Mieghem NM
    Europace; 2018 Dec; 20(12):1981-1988. PubMed ID: 29688322
    [TBL] [Abstract][Full Text] [Related]  

  • 16. One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.
    Salizzoni S; Anselmino M; Fornengo C; Giordana F; La Torre M; Moretti C; D'Amico M; Omedé P; Marra S; Rinaldi M; Gaita F
    J Cardiovasc Med (Hagerstown); 2015 Apr; 16(4):296-302. PubMed ID: 25719906
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation.
    Binder RK; Webb JG; Toggweiler S; Freeman M; Barbanti M; Willson AB; Alhassan D; Hague CJ; Wood DA; Leipsic J
    JACC Cardiovasc Interv; 2013 May; 6(5):462-8. PubMed ID: 23702010
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Permanent pacemaker implantation following transcatheter aortic valve replacement: still a concern?
    Urena M; Rodés-Cabau J
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):70-3. PubMed ID: 25616820
    [No Abstract]   [Full Text] [Related]  

  • 19. Electrophysiological evaluation of atrioventricular conduction disturbances in transcatheter aortic valve implantation with Edwards SAPIEN prosthesis.
    Eksik A; Gul M; Uyarel H; Surgit O; Yildirim A; Uslu N; Aksu H; Turen S; Uzun F; Satılmısoglu H; Erol MK; Bakir I
    J Invasive Cardiol; 2013 Jun; 25(6):305-9. PubMed ID: 23735359
    [TBL] [Abstract][Full Text] [Related]  

  • 20. "Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI.
    Latsios G; Gerckens U; Buellesfeld L; Mueller R; John D; Yuecel S; Syring J; Sauren B; Grube E
    Catheter Cardiovasc Interv; 2010 Sep; 76(3):431-9. PubMed ID: 20506410
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.