591 related articles for article (PubMed ID: 24994033)
1. The role of post-operative radiographs in predicting risk of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures - a case control study.
Selvan DR; Perry D; Machin DG; Brown DJ
Injury; 2014 Dec; 45(12):1885-8. PubMed ID: 24994033
[TBL] [Abstract][Full Text] [Related]
2. Effects of Volar Tilt, Wrist Extension, and Plate Position on Contact Between Flexor Pollicis Longus Tendon and Volar Plate.
Wurtzel CNW; Burns GT; Zhu AF; Ozer K
J Hand Surg Am; 2017 Dec; 42(12):996-1001. PubMed ID: 28927879
[TBL] [Abstract][Full Text] [Related]
3. The Effect of Plate Design on the Flexor Pollicis Longus Tendon After Volar Locked Plating of Distal Radial Fractures.
Stepan JG; Marshall DC; Wessel LE; Endo Y; Miller TT; Sacks HA; Weiland AJ; Fufa DT
J Bone Joint Surg Am; 2019 Sep; 101(17):1586-1592. PubMed ID: 31483402
[TBL] [Abstract][Full Text] [Related]
4. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus.
Limthongthang R; Bachoura A; Jacoby SM; Osterman AL
J Hand Surg Am; 2014 May; 39(5):852-60. PubMed ID: 24630941
[TBL] [Abstract][Full Text] [Related]
5. Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius.
Uemura T; Okano T; Onode E; Yokoi T; Shintani K; Okada M; Nakamura H
J Med Ultrason (2001); 2018 Oct; 45(4):647-651. PubMed ID: 29704082
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of flexor pollicis longus tendon attrition using color Doppler imaging after volar plate fixation for distal radius fracture.
Tanaka Y; Gotani H; Yano K; Sasaki K; Hamada Y
J Orthop Sci; 2017 May; 22(3):447-452. PubMed ID: 28325701
[TBL] [Abstract][Full Text] [Related]
7. Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study.
Sato K; Kikuchi Y; Mimata Y; Murakami K; Takahashi G; Doita M
J Orthop Traumatol; 2019 Aug; 20(1):29. PubMed ID: 31432281
[TBL] [Abstract][Full Text] [Related]
8. Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width.
Schlickum L; Quadlbauer S; Pezzei C; Stöphasius E; Hausner T; Leixnering M
Arch Orthop Trauma Surg; 2019 Feb; 139(2):269-279. PubMed ID: 30506496
[TBL] [Abstract][Full Text] [Related]
9. Asymptomatic Flexor Tendon Damages after Volar Locking Plate Fixation of Distal Radius Fractures.
Tokunaga S; Abe Y
J Hand Surg Asian Pac Vol; 2017 Mar; 22(1):75-82. PubMed ID: 28205485
[TBL] [Abstract][Full Text] [Related]
10. Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report.
Klug RA; Press CM; Gonzalez MH
J Hand Surg Am; 2007 Sep; 32(7):984-8. PubMed ID: 17826550
[TBL] [Abstract][Full Text] [Related]
11. Flexor pollicis longus dysfunction after volar plate fixation of distal radius fractures.
Chilelli BJ; Patel RM; Kalainov DM; Peng J; Zhang LQ
J Hand Surg Am; 2013 Sep; 38(9):1691-7. PubMed ID: 23910382
[TBL] [Abstract][Full Text] [Related]
12. Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures.
Tada K; Ikeda K; Shigemoto K; Suganuma S; Tsuchiya H
Hand Surg; 2011; 16(3):271-5. PubMed ID: 22072459
[TBL] [Abstract][Full Text] [Related]
13. Optimizing Volar Tilt Restoration and Plate Position in Distal Radius Fractures.
Sochol KM; Gluck M; McGough J; Hausman M
J Hand Surg Am; 2024 Jan; 49(1):64.e1-64.e7. PubMed ID: 35843762
[TBL] [Abstract][Full Text] [Related]
14. Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases.
Valbuena SE; Cogswell LK; Baraziol R; Valenti P
Chir Main; 2010 Apr; 29(2):109-13. PubMed ID: 20188619
[TBL] [Abstract][Full Text] [Related]
15. Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study.
Yamazaki H; Uchiyama S; Komatsu M; Hashimoto S; Kato H
J Hand Surg Am; 2015 Aug; 40(8):1571-81. PubMed ID: 25944553
[TBL] [Abstract][Full Text] [Related]
16. Flexor pollicis longus injury after corrective osteotomy of distal radius malunion with volar fixed-angle plating: case report and review literature of the flexor tendon injuries after volar plating.
Kosiyatrakul A; Luenam S; Prachaporn S
J Med Assoc Thai; 2012 Oct; 95 Suppl 10():S213-8. PubMed ID: 23451465
[TBL] [Abstract][Full Text] [Related]
17. Volar plate position and flexor tendon rupture following distal radius fracture fixation.
Kitay A; Swanstrom M; Schreiber JJ; Carlson MG; Nguyen JT; Weiland AJ; Daluiski A
J Hand Surg Am; 2013 Jun; 38(6):1091-6. PubMed ID: 23647641
[TBL] [Abstract][Full Text] [Related]
18. Ultrasonic Evaluation of the Flexor Pollicis Longus Tendon Following Volar Plate Fixation for Distal Radius Fractures.
Kara A; Celik H; Bankaoglu M; Oc Y; Bulbul M; Sugun TS
J Hand Surg Am; 2016 Mar; 41(3):374-80. PubMed ID: 26787412
[TBL] [Abstract][Full Text] [Related]
19. Volar locking plate implant prominence and flexor tendon rupture.
Soong M; Earp BE; Bishop G; Leung A; Blazar P
J Bone Joint Surg Am; 2011 Feb; 93(4):328-35. PubMed ID: 21239658
[TBL] [Abstract][Full Text] [Related]
20. Delayed Rupture of the Flexor Pollicis Longus After Volar Plating for a Distal Radius Fracture: A Case Report.
Rogers J; Hayes M; Van Demark REJ
S D Med; 2019 Nov; 72(11):514-517. PubMed ID: 31985902
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]