185 related articles for article (PubMed ID: 25004540)
1. Temperature rise in tissue ablation using multi-frequency ultrasound.
Sijia Guo ; Yun Jing ; Xiaoning Jiang
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Aug; 60(8):1699-707. PubMed ID: 25004540
[TBL] [Abstract][Full Text] [Related]
2. HIFU-induced cavitation and heating in ex vivo porcine subcutaneous fat.
Kyriakou Z; Corral-Baques MI; Amat A; Coussios CC
Ultrasound Med Biol; 2011 Apr; 37(4):568-79. PubMed ID: 21371810
[TBL] [Abstract][Full Text] [Related]
3. Correction of proton resonance frequency shift MR-thermometry errors caused by heat-induced magnetic susceptibility changes during high intensity focused ultrasound ablations in tissues containing fat.
Baron P; Deckers R; de Greef M; Merckel LG; Bakker CJ; Bouwman JG; Bleys RL; van den Bosch MA; Bartels LW
Magn Reson Med; 2014 Dec; 72(6):1580-9. PubMed ID: 24347129
[TBL] [Abstract][Full Text] [Related]
4. Determining temperature distribution in tissue in the focal plane of the high (>100 W/cm(2)) intensity focused ultrasound beam using phase shift of ultrasound echoes.
Karwat P; Kujawska T; Lewin PA; Secomski W; Gambin B; Litniewski J
Ultrasonics; 2016 Feb; 65():211-9. PubMed ID: 26498063
[TBL] [Abstract][Full Text] [Related]
5. Numerical prediction of frequency dependent 3D maps of mechanical index thresholds in ultrasonic brain therapy.
Pinton G; Aubry JF; Fink M; Tanter M
Med Phys; 2012 Jan; 39(1):455-67. PubMed ID: 22225316
[TBL] [Abstract][Full Text] [Related]
6. The correlation between bubble-enhanced HIFU heating and cavitation power.
Farny CH; Glynn Holt R; Roy RA
IEEE Trans Biomed Eng; 2010 Jan; 57(1):175-84. PubMed ID: 19651548
[TBL] [Abstract][Full Text] [Related]
7. The effects of Magnetic Resonance Imaging-guided High-Intensity Focused Ultrasound ablation on human cadaver breast tissue.
Merckel LG; Deckers R; Baron P; Bleys RL; van Diest PJ; Moonen CT; Mali WP; van den Bosch MA; Bartels LW
Eur J Pharmacol; 2013 Oct; 717(1-3):21-30. PubMed ID: 23583321
[TBL] [Abstract][Full Text] [Related]
8. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT
NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531
[TBL] [Abstract][Full Text] [Related]
9. Laser-induced fluorescence thermometry of heating in water from short bursts of high intensity focused ultrasound.
Al-Qraini MM; Canney MS; Oweis GF
Ultrasound Med Biol; 2013 Apr; 39(4):647-59. PubMed ID: 23497843
[TBL] [Abstract][Full Text] [Related]
10. A comparison of the thermal-dose equation and the intensity-time product, Itm, for predicting tissue damage thresholds.
Harris GR; Herman BA; Myers MR
Ultrasound Med Biol; 2011 Apr; 37(4):580-6. PubMed ID: 21376450
[TBL] [Abstract][Full Text] [Related]
11. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.
Courivaud F; Kazaryan AM; Lund A; Orszagh VC; Svindland A; Marangos IP; Halvorsen PS; Jebsen P; Fosse E; Hol PK; Edwin B
Ultrasound Med Biol; 2014 Jul; 40(7):1564-77. PubMed ID: 24768489
[TBL] [Abstract][Full Text] [Related]
12. Design, fabrication, and characterization of a single-aperture 1.5-MHz/3-MHz dual-frequency HIFU transducer.
Ma J; Guo S; Wu D; Geng X; Jiang X
IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Jul; 60(7):1519-29. PubMed ID: 25004519
[TBL] [Abstract][Full Text] [Related]
13. High-intensity focused ultrasound (HIFU) ablation by the frequency chirps: Enhanced thermal field and cavitation at the focus.
Wang M; Lei Y; Zhou Y
Ultrasonics; 2019 Jan; 91():134-149. PubMed ID: 30146323
[TBL] [Abstract][Full Text] [Related]
14. High power, low frequency ultrasound: meniscal tissue interaction and ablation characteristics.
O'Daly BJ; Morris E; Gavin GP; O'Keane C; O'Byrne JM; McGuinness GB
Ultrasound Med Biol; 2011 Apr; 37(4):556-67. PubMed ID: 21420582
[TBL] [Abstract][Full Text] [Related]
15. A feasibility study of temperature rise measurement in a tissue phantom as an alternative way for characterization of the therapeutic high intensity focused ultrasonic field.
Chen D; Fan T; Zhang D; Wu J
Ultrasonics; 2009 Dec; 49(8):733-42. PubMed ID: 19576607
[TBL] [Abstract][Full Text] [Related]
16. Pre-clinical study of in vivo magnetic resonance-guided bubble-enhanced heating in pig liver.
Elbes D; Denost Q; Laurent C; Trillaud H; Rullier A; Quesson B
Ultrasound Med Biol; 2013 Aug; 39(8):1388-97. PubMed ID: 23562012
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of focused ultrasound algorithms: Issues for reducing pre-focal heating and treatment time.
Yiannakou M; Trimikliniotis M; Yiallouras C; Damianou C
Ultrasonics; 2016 Feb; 65():145-53. PubMed ID: 26476464
[TBL] [Abstract][Full Text] [Related]
18. Synergistic ablation of liver tissue and liver cancer cells with high-intensity focused ultrasound and ethanol.
Hoang NH; Murad HY; Ratnayaka SH; Chen C; Khismatullin DB
Ultrasound Med Biol; 2014 Aug; 40(8):1869-81. PubMed ID: 24798386
[TBL] [Abstract][Full Text] [Related]
19. A real-time controller for sustaining thermally relevant acoustic cavitation during ultrasound therapy.
Hockham N; Coussios CC; Arora M
IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2685-94. PubMed ID: 21156364
[TBL] [Abstract][Full Text] [Related]
20. Frequency considerations for deep ablation with high-intensity focused ultrasound: A simulation study.
Ellens N; Hynynen K
Med Phys; 2015 Aug; 42(8):4896-10. PubMed ID: 26233216
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]