98 related articles for article (PubMed ID: 25005848)
1. Spatial resolution is dependent on image content for SPECT with iterative reconstruction incorporating distance dependent resolution (DDR) correction.
Badger D; Barnden L
Australas Phys Eng Sci Med; 2014 Sep; 37(3):551-7. PubMed ID: 25005848
[TBL] [Abstract][Full Text] [Related]
2. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
[TBL] [Abstract][Full Text] [Related]
3. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
4. [Simultaneous spatial resolution correction in SPECT reconstruction using OS-EM algorithm].
Maeda H; Yamaki N; Natsume T; Takeda K; Hasebe S; Kinda A; Motomura N
Igaku Butsuri; 2004; 24(2):61-71. PubMed ID: 15383710
[TBL] [Abstract][Full Text] [Related]
5. Nonuniform transmission in brain SPECT using 201Tl, 153Gd, and 99mTc static line sources: anthropomorphic dosimetry studies and influence on brain quantification.
Van Laere K; Koole M; Kauppinen T; Monsieurs M; Bouwens L; Dierck R
J Nucl Med; 2000 Dec; 41(12):2051-62. PubMed ID: 11138692
[TBL] [Abstract][Full Text] [Related]
6. Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.
Zeng GL; Gullberg GT; Bai C; Christian PE; Trisjono F; Di Bella EV; Tanner JW; Morgan HT
J Nucl Med; 1998 Jan; 39(1):124-30. PubMed ID: 9443751
[TBL] [Abstract][Full Text] [Related]
7. Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.
Okuda K; Nakajima K; Yamada M; Wakabayashi H; Ichikawa H; Arai H; Matsuo S; Taki J; Hashimoto M; Kinuya S
Ann Nucl Med; 2014 Jan; 28(1):60-8. PubMed ID: 24214735
[TBL] [Abstract][Full Text] [Related]
8. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.
Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A
Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145
[TBL] [Abstract][Full Text] [Related]
9. Development and evaluation of QSPECT open-source software for the iterative reconstruction of SPECT images.
Loudos GK; Papadimitroulas P; Zotos P; Tsougos I; Georgoulias P
Nucl Med Commun; 2010 Jun; 31(6):558-66. PubMed ID: 20351598
[TBL] [Abstract][Full Text] [Related]
10. Comparison of advanced iterative reconstruction methods for SPECT/CT.
Knoll P; Kotalova D; Köchle G; Kuzelka I; Minear G; Mirzaei S; Sámal M; Zadrazil L; Bergmann H
Z Med Phys; 2012 Feb; 22(1):58-69. PubMed ID: 21723716
[TBL] [Abstract][Full Text] [Related]
11. Improvement of brain perfusion SPET using iterative reconstruction with scatter and non-uniform attenuation correction.
Kauppinen T; Koskinen MO; Alenius S; Vanninen E; Kuikka JT
Eur J Nucl Med; 2000 Sep; 27(9):1380-6. PubMed ID: 11007521
[TBL] [Abstract][Full Text] [Related]
12. [High resolution reconstruction of PET images using the iterative OSEM algorithm].
Doll J; Henze M; Bublitz O; Werling A; Adam LE; Haberkorn U; Semmler W; Brix G
Nuklearmedizin; 2004 Jun; 43(3):72-8. PubMed ID: 15201947
[TBL] [Abstract][Full Text] [Related]
13. Transmission imaging for nonuniform attenuation correction using a three-headed SPECT camera.
Gilland DR; Jaszczak RJ; Greer KL; Coleman RE
J Nucl Med; 1998 Jun; 39(6):1105-10. PubMed ID: 9627354
[TBL] [Abstract][Full Text] [Related]
14. Intrinsic uniformity requirements for pinhole SPECT.
Seret A; Bleeser F
J Nucl Med Technol; 2006 Mar; 34(1):43-7. PubMed ID: 16517968
[TBL] [Abstract][Full Text] [Related]
15. Approximate 3D iterative reconstruction for SPECT.
Gilland DR; Jaszczak RJ; Riauka TA; Coleman RE
Med Phys; 1997 Sep; 24(9):1421-9. PubMed ID: 9304570
[TBL] [Abstract][Full Text] [Related]
16. Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals.
Brix G; Doll J; Bellemann ME; Trojan H; Haberkorn U; Schmidlin P; Ostertag H
Eur J Nucl Med; 1997 Jul; 24(7):779-86. PubMed ID: 9211765
[TBL] [Abstract][Full Text] [Related]
17. [Optimization of PET image quality by means of 3D data acquisition and iterative image reconstruction].
Doll J; Zaers J; Trojan H; Bellemann ME; Adam LE; Haberkorn U; Brix G
Nuklearmedizin; 1998 Mar; 37(2):62-7. PubMed ID: 9547752
[TBL] [Abstract][Full Text] [Related]
18. Resolution improvement and noise reduction in human pinhole SPECT using a multi-ray approach and the SHINE method.
Seret A; Vanhove C; Defrise M
Nuklearmedizin; 2009; 48(4):159-65. PubMed ID: 19488460
[TBL] [Abstract][Full Text] [Related]
19. Aperture correction with an asymmetrically trimmed Gaussian weight in SPECT with a fan-beam collimator.
Kamiya R; Ogawa K
Ann Nucl Med; 2013 Aug; 27(7):661-8. PubMed ID: 23670088
[TBL] [Abstract][Full Text] [Related]
20. [Influence of the Pixel Sizes of Reference Computed Tomography on Single-photon Emission Computed Tomography Image Reconstruction Using Conjugate-gradient Algorithm].
Okuda K; Sakimoto S; Fujii S; Ida T; Moriyama S
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2017; 73(10):1039-1044. PubMed ID: 29057775
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]