134 related articles for article (PubMed ID: 25009186)
1. A high-resolution map of gamma dose rates in Cluj County, Romania using LiF:Mg,Cu,P detectors.
Dolha M; Timar-Gabor A; Dicu T; Begy R; Anton M; Cosma C
Radiat Prot Dosimetry; 2014 Nov; 162(1-2):14-9. PubMed ID: 25009186
[TBL] [Abstract][Full Text] [Related]
2. Application of whole-body personal TL dosemeters in mixed field beta-gamma radiation.
Ciupek K; Aksamit D; Wołoszczuk K
Radiat Prot Dosimetry; 2014 Nov; 162(1-2):20-3. PubMed ID: 25009188
[TBL] [Abstract][Full Text] [Related]
3. Long-term stability of Harshaw LiF:Mg,Cu,P TLDS.
Gilvin PJ; Burkett RA; Baker ST; Garratt NJ
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):192-4. PubMed ID: 21216732
[TBL] [Abstract][Full Text] [Related]
4. TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H) WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07).
Pereira JS; Pereira MF; Rangel S; Caldeira M; Carvalhal G; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2019 Aug; 184(2):216-223. PubMed ID: 30496554
[TBL] [Abstract][Full Text] [Related]
5. UV-induced bleaching of deep traps in Harshaw TLD LiF:Mg,Cu,P and LiF:Mg,Ti.
Benevides L; Voss S; Nita I; Rotunda J; Velbeck K; Luo LZ; Moscovitch M
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):199-201. PubMed ID: 21310735
[TBL] [Abstract][Full Text] [Related]
6. Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoring.
Carinou E; Askounis P; Dimitropoulou F; Kiranos G; Kyrgiakou H; Nirgianaki E; Papadomarkaki E; Kamenopoulou V
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):207-10. PubMed ID: 21199822
[TBL] [Abstract][Full Text] [Related]
7. Energy response of different types of RADOS personal dosemeters with MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P) TL detectors.
Obryk B; Hranitzky C; Stadtmann H; Budzanowski M; Olko P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):211-4. PubMed ID: 21227957
[TBL] [Abstract][Full Text] [Related]
8. Evaluating the performance of the Harshaw™ DXTRAD LiF:Mg,Cu,P finger ring with two different thickness filters.
Baker ST; Roberts GH; Gilvin PJ
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):243-5. PubMed ID: 21212080
[TBL] [Abstract][Full Text] [Related]
9. Method of thermoluminescent measurement of radiation doses from micrograys up to a megagray with a single LiF:Mg,Cu,P detector.
Obryk B; Bilski P; Olko P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):543-7. PubMed ID: 21051430
[TBL] [Abstract][Full Text] [Related]
10. Individual monitoring in nuclear medicine therapeutic procedures using extremity dosemeters LiF(Mg, Cu, P).
Sarti G; Del Dottore F; Fabbri C; Tassinari L; Pagan S; Rustignoli M; Motta P
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):521-4. PubMed ID: 21030398
[TBL] [Abstract][Full Text] [Related]
11. FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.
Pereira J; Pereira MF; Rangel S; Saraiva M; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):177-80. PubMed ID: 26503857
[TBL] [Abstract][Full Text] [Related]
12. The effect of Mg, Cu and P impurities on dose response of LiF:Mg,Cu,P phosphors: simulation versus experiments.
Mohammadi K; Khayat O; Afarideh H
Radiat Prot Dosimetry; 2016 Jan; 168(1):19-26. PubMed ID: 25634900
[TBL] [Abstract][Full Text] [Related]
13. The applicability of the PTTL dose re-analysis method to the Harshaw LiF:Mg,Cu,P material.
Moscovitch M; Benevides L; Romanyukha A; Hull F; Duffy M; Voss S; Velbeck KJ; Nita I; Rotunda JE
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):161-4. PubMed ID: 21450701
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of the performance of two LiF:Mg,Ti and LiF:Mg,Cu,P dosemeters for extremity monitoring.
Freire LC; Pereira MF; Calado AM; Santos LM; Cardoso JV; Alves JG
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):140-3. PubMed ID: 21081520
[TBL] [Abstract][Full Text] [Related]
15. A system for rapid large-area monitoring of gamma dose rates in the environment based on MCP-N (LiF:Mg,Cu,P) TL detectors.
Budzanowski M; Olko P; Ryba E; Woźnicka U
Radiat Prot Dosimetry; 2002; 101(1-4):205-9. PubMed ID: 12382736
[TBL] [Abstract][Full Text] [Related]
16. THE INFLUENCE OF PRE- AND POST-IRRADIATION ANNEALING ON LiF:Mg,Cu,P STABILITY.
Matusiak K; Patora A; Jung A
Radiat Prot Dosimetry; 2016 Nov; 171(3):346-350. PubMed ID: 26359334
[TBL] [Abstract][Full Text] [Related]
17. ENEA extremity dosemeter based on LiF(Mg,Cu,P) to evaluate Hp(3,alpha).
Mariotti F; Fantuzzi E; Morelli B; Gualdrini G; Botta MC; Uleri G; Bordy JM; Denoziere M
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):187-91. PubMed ID: 21224262
[TBL] [Abstract][Full Text] [Related]
18. Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.
Ginjaume M; Pérez S; Ortega X; Duch MA
Radiat Prot Dosimetry; 2006; 120(1-4):316-20. PubMed ID: 16644980
[TBL] [Abstract][Full Text] [Related]
19. Comparison of the TL responses of two different preparations of LiF:Mg,Cu,P irradiated by photons of various energies.
González PR; Furetta C; Azorín J
Appl Radiat Isot; 2007 Mar; 65(3):341-4. PubMed ID: 17085055
[TBL] [Abstract][Full Text] [Related]
20. Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response.
Hranitzky C; Stadtmann H; Olko P
Radiat Prot Dosimetry; 2006; 119(1-4):483-6. PubMed ID: 16822775
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]