These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
224 related articles for article (PubMed ID: 25010783)
1. Average current is better than peak current as therapeutic dosage for biphasic waveforms in a ventricular fibrillation pig model of cardiac arrest. Chen B; Yu T; Ristagno G; Quan W; Li Y Resuscitation; 2014 Oct; 85(10):1399-404. PubMed ID: 25010783 [TBL] [Abstract][Full Text] [Related]
2. Current is better than energy as predictor of success for biphasic defibrillatory shocks in a porcine model of ventricular fibrillation. Ristagno G; Yu T; Quan W; Freeman G; Li Y Resuscitation; 2013 May; 84(5):678-83. PubMed ID: 23032689 [TBL] [Abstract][Full Text] [Related]
3. Comparison of efficacy of pulsed biphasic waveform and rectilinear biphasic waveform in a short ventricular fibrillation pig model. Li Y; Wang H; Cho JH; Didon JP; Bisera J; Weil MH; Tang W Resuscitation; 2009 Sep; 80(9):1047-51. PubMed ID: 19604618 [TBL] [Abstract][Full Text] [Related]
4. Effects of biphasic waveforms on outcomes of cardiopulmonary resuscitation in a porcine model of prolonged cardiac arrest. Chang YT; Tang W; Wang J; Brewer JE; Freeman G; Sun S; Weil MH Crit Care Med; 2006 Dec; 34(12):3024-8. PubMed ID: 17075369 [TBL] [Abstract][Full Text] [Related]
5. The effects of second and third phase duration on defibrillation efficacy of triphasic rectangle waveforms. Tang C; Wang P; Gong Y; Wei L; Li Y; Zhang S Resuscitation; 2016 May; 102():57-62. PubMed ID: 26939971 [TBL] [Abstract][Full Text] [Related]
6. Quadriphasic waveforms are superior to triphasic waveforms for transthoracic defibrillation in a cardiac arrest swine model with high impedance. Zhang Y; Rhee B; Davies LR; Zimmerman MB; Snyder D; Jones JL; Kerber RE Resuscitation; 2006 Feb; 68(2):251-8. PubMed ID: 16325983 [TBL] [Abstract][Full Text] [Related]
7. The effects of phase duration on defibrillation success of dual time constant biphasic waveforms. Shan Y; Ristagno G; Fuller M; Sun S; Li Y; Weil MH; Russell J; Tang W Resuscitation; 2010 Feb; 81(2):236-41. PubMed ID: 19945206 [TBL] [Abstract][Full Text] [Related]
8. Out-of-hospital cardiac arrest rectilinear biphasic to monophasic damped sine defibrillation waveforms with advanced life support intervention trial (ORBIT). Morrison LJ; Dorian P; Long J; Vermeulen M; Schwartz B; Sawadsky B; Frank J; Cameron B; Burgess R; Shield J; Bagley P; Mausz V; Brewer JE; Lerman BB; Resuscitation; 2005 Aug; 66(2):149-57. PubMed ID: 15992986 [TBL] [Abstract][Full Text] [Related]
9. Comparison of rectilinear biphasic waveform with biphasic truncated exponential waveform in a pediatric defibrillation model. Wang J; Tang W; Brewer JE; Freeman G; Chang YT; Weil MH Crit Care Med; 2007 Aug; 35(8):1961-5. PubMed ID: 17581484 [TBL] [Abstract][Full Text] [Related]
10. A comparison of defibrillation efficacy between different impedance compensation techniques in high impedance porcine model. Li Y; Ristagno G; Yu T; Bisera J; Weil MH; Tang W Resuscitation; 2009 Nov; 80(11):1312-7. PubMed ID: 19720442 [TBL] [Abstract][Full Text] [Related]
11. The effects of biphasic and conventional monophasic defibrillation on postresuscitation myocardial function. Tang W; Weil MH; Sun S; Yamaguchi H; Povoas HP; Pernat AM; Bisera J J Am Coll Cardiol; 1999 Sep; 34(3):815-22. PubMed ID: 10483965 [TBL] [Abstract][Full Text] [Related]
12. Surgical open-chest ventricular defibrillation: triphasic waveforms are superior to biphasic waveforms. Zhang Y; Boddicker KA; Davies LR; Jones JL; Kerber RE Pacing Clin Electrophysiol; 2004 Jul; 27(7):941-8. PubMed ID: 15271014 [TBL] [Abstract][Full Text] [Related]
13. Comparison of defibrillation efficacy between two pads placements in a pediatric porcine model of cardiac arrest. Ristagno G; Yu T; Quan W; Freeman G; Li Y Resuscitation; 2012 Jun; 83(6):755-9. PubMed ID: 22198420 [TBL] [Abstract][Full Text] [Related]
14. Transthoracic biphasic waveform defibrillation at very high and very low energies: a comparison with monophasic waveforms in an animal model of ventricular fibrillation. Clark CB; Zhang Y; Davies LR; Karlsson G; Kerber RE Resuscitation; 2002 Aug; 54(2):183-6. PubMed ID: 12161298 [TBL] [Abstract][Full Text] [Related]
16. Treatment of out-of-hospital cardiac arrest with a low-energy impedance-compensating biphasic waveform automatic external defibrillator. The LIFE Investigators. Gliner BE; Jorgenson DB; Poole JE; White RD; Kanz KG; Lyster TD; Leyde KW; Powers DJ; Morgan CB; Kronmal RA; Bardy GH Biomed Instrum Technol; 1998; 32(6):631-44. PubMed ID: 9883348 [TBL] [Abstract][Full Text] [Related]
17. Low-tilt monophasic and biphasic waveforms compared with standard biphasic waveforms in the transvenous defibrillation of ventricular fibrillation. Bennett JR; Darragh KM; Walsh SJ; Allen DJ; Scott M; Stevenson M; Adgey JA; Anderson JM; Manoharan G Pacing Clin Electrophysiol; 2014 Mar; 37(3):279-89. PubMed ID: 24102186 [TBL] [Abstract][Full Text] [Related]
18. A comparison of rectilinear and truncated exponential biphasic waveforms in elective cardioversion of atrial fibrillation: a prospective randomized controlled trial. Deakin CD; Connelly S; Wharton R; Yuen HM Resuscitation; 2013 Mar; 84(3):286-91. PubMed ID: 22842285 [TBL] [Abstract][Full Text] [Related]
19. A Grouped Up-and-Down Method Used for Efficacy Comparison Between Two Different Defibrillation Waveforms. Jin D; Wang J; Yang K; Wang K; Quan W; Herken U; Li Y IEEE Trans Biomed Eng; 2016 Feb; 63(2):385-91. PubMed ID: 26208263 [TBL] [Abstract][Full Text] [Related]
20. A prospective, randomised and blinded comparison of first shock success of monophasic and biphasic waveforms in out-of-hospital cardiac arrest. van Alem AP; Chapman FW; Lank P; Hart AA; Koster RW Resuscitation; 2003 Jul; 58(1):17-24. PubMed ID: 12867305 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]