These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 25015325)

  • 1. How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?
    Reinders J; Sonntag R; Kretzer JP
    J Mater Sci Mater Med; 2014 Nov; 25(11):2463-9. PubMed ID: 25015325
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Calf serum constituent fractions influence polyethylene wear and microbial growth in knee simulator testing.
    Brandt JM; Charron K; Zhao L; MacDonald SJ; Medley JB
    Proc Inst Mech Eng H; 2012 Jun; 226(6):427-40. PubMed ID: 22783759
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing.
    Schwenke T; Kaddick C; Schneider E; Wimmer MA;
    Proc Inst Mech Eng H; 2005 Nov; 219(6):457-64. PubMed ID: 16312105
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Wear simulation of a polyethylene-on-metal cervical total disc replacement under different concentrations of bovine serum lubricant.
    Hyde PJ; Fisher J; Hall RM
    Proc Inst Mech Eng H; 2016 May; 230(5):481-8. PubMed ID: 27160565
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant.
    DesJardins J; Aurora A; Tanner SL; Pace TB; Acampora KB; Laberge M
    Proc Inst Mech Eng H; 2006 Jul; 220(5):609-23. PubMed ID: 16898218
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Wear of moderately cross-linked polyethylene in fixed-bearing total knee replacements.
    Brockett CL; Jennings LM; Hardaker C; Fisher J
    Proc Inst Mech Eng H; 2012 Jul; 226(7):529-35. PubMed ID: 22913100
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of the loading frequency on the wear rate of a polyethylene-on-metal lumbar intervertebral disc replacement.
    Kettler A; Bushelow M; Wilke HJ
    Eur Spine J; 2012 Jun; 21 Suppl 5(Suppl 5):S709-16. PubMed ID: 20936310
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Synovial fluid replication in knee wear testing: an investigation of the fluid volume.
    Reinders J; Sonntag R; Kretzer JP
    J Orthop Res; 2015 Jan; 33(1):92-7. PubMed ID: 25244424
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Knee wear simulation under conditions of highly demanding daily activities--influence on an unicompartmental fixed bearing knee design.
    Schwiesau J; Schilling C; Utzschneider S; Jansson V; Fritz B; Blömer W; Grupp TM
    Med Eng Phys; 2013 Aug; 35(8):1204-11. PubMed ID: 23380535
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings.
    Ali M; Al-Hajjar M; Partridge S; Williams S; Fisher J; Jennings LM
    Proc Inst Mech Eng H; 2016 May; 230(5):389-97. PubMed ID: 27160559
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The biochemical characteristics of wear testing lubricants affect polyethylene wear in orthopaedic pin-on-disc testing.
    Guenther LE; Turgeon TR; Bohm ER; Brandt JM
    Proc Inst Mech Eng H; 2015 Jan; 229(1):77-90. PubMed ID: 25655957
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measures for reducing ultra-high-molecular-weight polyethylene wear in total knee replacement: a simulator study.
    Mueller-Rath R; Kleffner B; Andereya S; Mumme T; Wirtz DC
    Biomed Tech (Berl); 2007 Aug; 52(4):295-300. PubMed ID: 17691863
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
    Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
    Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model.
    Sorimachi T; Clarke IC; Williams PA; Gustafson A; Yamamoto K
    Proc Inst Mech Eng H; 2009 Jul; 223(5):607-23. PubMed ID: 19623913
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses.
    Delport HP; Sloten JV; Bellemans J
    Acta Orthop Belg; 2010 Jun; 76(3):367-73. PubMed ID: 20698459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials.
    Scholes SC; Joyce TJ
    Proc Inst Mech Eng H; 2013 Jun; 227(6):693-703. PubMed ID: 23636752
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mass gain behaviour of tibial polyethylene inserts during soak testing.
    Brandt JM; Charron KD; MacDonald SJ; Medley JB
    Proc Inst Mech Eng H; 2011 Mar; 225(3):324-31. PubMed ID: 21485333
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predicting knee replacement damage in a simulator machine using a computational model with a consistent wear factor.
    Zhao D; Sakoda H; Sawyer WG; Banks SA; Fregly BJ
    J Biomech Eng; 2008 Feb; 130(1):011004. PubMed ID: 18298180
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simplified motion and loading compared to physiological motion and loading in a hip joint simulator.
    Smith SL; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(3):233-8. PubMed ID: 10902437
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.