BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 25016166)

  • 1. Simultaneous determination of metformin and vildagliptin in human plasma by a HILIC-MS/MS method.
    Pontarolo R; Gimenez AC; de Francisco TM; Ribeiro RP; Pontes FL; Gasparetto JC
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Aug; 965():133-41. PubMed ID: 25016166
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative determination of metformin, saxagliptin and 5-hydroxy saxagliptin simultaneously by hydrophilic interaction liquid chromatography - electrospray ionization mass spectrometry and its application to a bioequivalence study with a single-pill combination in human.
    Peng Y; Chang Q; Yang N; Gu S; Zhou Y; Yin L; Aa J; Wang G; Sun J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Apr; 1081-1082():109-117. PubMed ID: 29518719
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new HILIC-MS/MS method for the simultaneous analysis of carbidopa, levodopa, and its metabolites in human plasma.
    Vilhena Rde O; Pontes FL; Marson BM; Ribeiro RP; de Carvalho KA; Cardoso MA; Pontarolo R
    J Chromatogr B Analyt Technol Biomed Life Sci; 2014 Sep; 967():41-9. PubMed ID: 25063927
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of metformin in rat plasma by HILIC-MS/MS combined with Tecan automation and direct injection.
    Zhang W; Han F; Zhao H; Lin ZJ; Huang QM; Weng N
    Biomed Chromatogr; 2012 Oct; 26(10):1163-9. PubMed ID: 22213213
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of LC-MS/MS method applied to evaluation of free tissue concentrations of vildagliptin in diabetic rats by microdialysis.
    de Andrade C; de Araújo Lock G; Pigatto MC; Haas SE; Costa TD; de Araújo BV
    Biomed Chromatogr; 2014 Dec; 28(12):1722-7. PubMed ID: 24771661
    [TBL] [Abstract][Full Text] [Related]  

  • 6. LC-MS/MS analysis of metformin, saxagliptin and 5-hydroxy saxagliptin in human plasma and its pharmacokinetic study with a fixed-dose formulation in healthy Indian subjects.
    Shah PA; Shah JV; Sanyal M; Shrivastav PS
    Biomed Chromatogr; 2017 Mar; 31(3):. PubMed ID: 27508356
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of metformin in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry.
    Liu A; Coleman SP
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Nov; 877(29):3695-700. PubMed ID: 19783231
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination and pharmacokinetic study of metformin and pioglitazone in dog plasma by LC-MS-MS.
    Zhang X; Peng Y; Wan P; Yin L; Wang G; Sun J
    J Chromatogr Sci; 2014 Jan; 52(1):52-8. PubMed ID: 23293039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of validated stability indicating assay method for simultaneous estimation of metformin hydrochloride and vildagliptin by RP-HPLC.
    Satheeshkumar N; Pradeepkumar M; Shanthikumar S; Rao VJ
    Drug Res (Stuttg); 2014 Mar; 64(3):124-9. PubMed ID: 24081820
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Simultaneous determination of metformin and glipizide in human plasma by liquid chromatography-tandem mass spectrometry].
    Zhao XH; Song B; Zhong DF; Zhang SQ; Chen XY
    Yao Xue Xue Bao; 2007 Oct; 42(10):1087-91. PubMed ID: 18229619
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development and Validation of a Method for Simultaneous Estimation of Metformin and Sitagliptin in Human Plasma by LC-MS-MS and Its Application in a Bioequivalence Study.
    Reddy S; Ahmed I; Ahmad I; Mukhopadhyay A; Thangam S
    J Chromatogr Sci; 2015 Oct; 53(9):1549-56. PubMed ID: 25987553
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous quantification of metformin and glipizide in human plasma by high-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study.
    Li N; Deng Y; Qin F; Yu J; Li F
    Biomed Chromatogr; 2013 Feb; 27(2):191-6. PubMed ID: 22763773
    [TBL] [Abstract][Full Text] [Related]  

  • 13. LC-MS/MS-ESI method for simultaneous quantitation of metformin and repaglinidie in rat plasma and its application to pharmacokinetic study in rats.
    Sharma K; Pawar G; Yadam S; Giri S; Rajagopal S; Mullangi R
    Biomed Chromatogr; 2013 Mar; 27(3):356-64. PubMed ID: 22865648
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and validation of a highly sensitive LC-MS/MS-ESI method for the determination of bicalutamide in mouse plasma: application to a pharmacokinetic study.
    Sharma K; Pawar GV; Giri S; Rajagopal S; Mullangi R
    Biomed Chromatogr; 2012 Dec; 26(12):1589-95. PubMed ID: 22495777
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous determination of metformin and rosiglitazone in human plasma by liquid chromatography/tandem mass spectrometry with electrospray ionization: application to a pharmacokinetic study.
    Zhang L; Tian Y; Zhang Z; Chen Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jul; 854(1-2):91-8. PubMed ID: 17459785
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of pethidine in human plasma by LC-MS/MS.
    Wang X; Xiang Z; Cai X; Wu H; Wang X; Li J; Zhang M
    Biomed Chromatogr; 2011 Jul; 25(7):833-7. PubMed ID: 20872940
    [TBL] [Abstract][Full Text] [Related]  

  • 17. LC-MS/MS Determination of Empagliflozin and Metformin.
    Ayoub BM; Mowaka S
    J Chromatogr Sci; 2017 Aug; 55(7):742-747. PubMed ID: 28383657
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hydrophilic Interaction Liquid Chromatography-Electrospray Ionization Mass Spectrometry for Therapeutic Drug Monitoring of Metformin and Rosuvastatin in Human Plasma.
    Antonopoulos N; Machairas G; Migias G; Vonaparti A; Brakoulia V; Pistos C; Gennimata D; Panderi I
    Molecules; 2018 Jun; 23(7):. PubMed ID: 29954074
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An efficient hydrophilic interaction liquid chromatographic method for the simultaneous determination of metformin and pioglitazone using high-purity silica column.
    Mohamed AM; Mohamed FA; Ahmed S; Mohamed YA
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Aug; 997():16-22. PubMed ID: 26079265
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of gabapentin in human plasma using hydrophilic interaction liquid chromatography with tandem mass spectrometry.
    Ji HY; Jeong DW; Kim YH; Kim HH; Yoon YS; Lee KC; Lee HS
    Rapid Commun Mass Spectrom; 2006; 20(14):2127-32. PubMed ID: 16773671
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.