BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 25018050)

  • 1. Gafchromic film dosimetry: four years experience using FilmQA Pro software and Epson flatbed scanners.
    Mathot M; Sobczak S; Hoornaert MT
    Phys Med; 2014 Dec; 30(8):871-7. PubMed ID: 25018050
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure.
    Menegotti L; Delana A; Martignano A
    Med Phys; 2008 Jul; 35(7):3078-85. PubMed ID: 18697531
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
    Ferreira BC; Lopes MC; Capela M
    Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.
    Lynch BD; Kozelka J; Ranade MK; Li JG; Simon WE; Dempsey JF
    Med Phys; 2006 Dec; 33(12):4551-6. PubMed ID: 17278806
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry.
    Lewis D; Chan MF
    Med Phys; 2015 Jan; 42(1):416-29. PubMed ID: 25563282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
    Paelinck L; De Neve W; De Wagter C
    Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
    [TBL] [Abstract][Full Text] [Related]  

  • 7. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
    Saur S; Frengen J
    Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
    [TBL] [Abstract][Full Text] [Related]  

  • 8. COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS.
    Dufek V; Horakova I; Koniarova I
    Radiat Prot Dosimetry; 2019 Dec; 186(2-3):357-361. PubMed ID: 31711200
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multichannel film dosimetry with nonuniformity correction.
    Micke A; Lewis DF; Yu X
    Med Phys; 2011 May; 38(5):2523-34. PubMed ID: 21776787
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density.
    Marroquin EY; Herrera González JA; Camacho López MA; Barajas JE; García-Garduño OA
    J Appl Clin Med Phys; 2016 Sep; 17(5):466-481. PubMed ID: 27685125
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Linearization of dose-response curve of the radiochromic film dosimetry system.
    Devic S; Tomic N; Aldelaijan S; Deblois F; Seuntjens J; Chan MF; Lewis D
    Med Phys; 2012 Aug; 39(8):4850-7. PubMed ID: 22894411
    [TBL] [Abstract][Full Text] [Related]  

  • 12. GafChromic(®) EBT3 films for patient specific IMRT QA using a multichannel approach.
    Marrazzo L; Zani M; Pallotta S; Arilli C; Casati M; Compagnucci A; Talamonti C; Bucciolini M
    Phys Med; 2015 Dec; 31(8):1035-1042. PubMed ID: 26429383
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
    Dreindl R; Georg D; Stock M
    Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance.
    Aland T; Kairn T; Kenny J
    Australas Phys Eng Sci Med; 2011 Jun; 34(2):251-60. PubMed ID: 21465275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners for use in IMRT dosimetry using gafchromic and radiographic film.
    Wilcox E; Daskalov G; Nedialkova L
    Med Phys; 2007 Jan; 34(1):41-8. PubMed ID: 17278488
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction.
    Chung H; Lynch B; Samant S
    J Appl Clin Med Phys; 2010 Apr; 11(2):3112. PubMed ID: 20592696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry.
    Matney JE; Parker BC; Neck DW; Henkelmann G; Rosen II
    J Appl Clin Med Phys; 2010 Apr; 11(2):3165. PubMed ID: 20592699
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry.
    Desroches J; Bouchard H; Lacroix F
    Med Phys; 2010 Apr; 37(4):1565-70. PubMed ID: 20443477
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability.
    Chen SN; Gauthier M; Bazalova-Carter M; Bolanos S; Glenzer S; Riquier R; Revet G; Antici P; Morabito A; Propp A; Starodubtsev M; Fuchs J
    Rev Sci Instrum; 2016 Jul; 87(7):073301. PubMed ID: 27475550
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Gafchromic EBT2 film dosimetry in reflection mode with a novel plan-based calibration method.
    Mendez I; Hartman V; Hudej R; Strojnik A; Casar B
    Med Phys; 2013 Jan; 40(1):011720. PubMed ID: 23298090
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.