These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
81 related articles for article (PubMed ID: 2502998)
1. Application of non-radioactive BACTEC system to sterility testing and hygiene. Hammann R; Kunert U Zentralbl Hyg Umweltmed; 1989 Jun; 188(3-4):294-302. PubMed ID: 2502998 [TBL] [Abstract][Full Text] [Related]
2. Comparison of the BACTEC MYCO/F Lytic bottle to the isolator tube, BACTEC Plus Aerobic F/bottle, and BACTEC Anaerobic Lytic/10 bottle and comparison of the BACTEC Plus Aerobic F/bottle to the Isolator tube for recovery of bacteria, mycobacteria, and fungi from blood. Vetter E; Torgerson C; Feuker A; Hughes J; Harmsen S; Schleck C; Horstmeier C; Roberts G; Cockerill F J Clin Microbiol; 2001 Dec; 39(12):4380-6. PubMed ID: 11724848 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products. Parveen S; Kaur S; David SA; Kenney JL; McCormick WM; Gupta RK Vaccine; 2011 Oct; 29(45):8012-23. PubMed ID: 21871516 [TBL] [Abstract][Full Text] [Related]
4. Comparison of automated culture systems with a CFR/USP-compliant method for sterility testing of cell-therapy products. Khuu HM; Stock F; McGann M; Carter CS; Atkins JW; Murray PR; Read EJ Cytotherapy; 2004; 6(3):183-95. PubMed ID: 15203975 [TBL] [Abstract][Full Text] [Related]
5. [Growth and detection of aerobic bacterial pathogens in BacT/Alert FA, BacT/Alert SA, Bactec Plus Aerobic/F and Bactec Standard Aerobic/F]. Cermák P; Sedláková P; Mejstríková L; Mazurová J Klin Mikrobiol Infekc Lek; 2006 Aug; 12(4):156-60. PubMed ID: 16958021 [TBL] [Abstract][Full Text] [Related]
6. Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system. Jungkind D; Millan J; Allen S; Dyke J; Hill E J Clin Microbiol; 1986 Feb; 23(2):262-6. PubMed ID: 3084548 [TBL] [Abstract][Full Text] [Related]
7. Lessons from the organization of a proficiency testing program in food microbiology by interlaboratory comparison: analytical methods in use, impact of methods on bacterial counts and measurement uncertainty of bacterial counts. Augustin JC; Carlier V Food Microbiol; 2006 Feb; 23(1):1-38. PubMed ID: 16942983 [TBL] [Abstract][Full Text] [Related]
8. Roadmap to approval: use of an automated sterility test method as a lot release test for Carticel, autologous cultured chondrocytes. Kielpinski G; Prinzi S; Duguid J; du Moulin G Cytotherapy; 2005; 7(6):531-41. PubMed ID: 16306015 [TBL] [Abstract][Full Text] [Related]
9. [Yield of blood cultures in relation to the cultured blood volume in Bactec 6A bottles]. Mensa J; Almela M; Casals C; Martínez JA; Marco F; Tomás R; Vidal F; Soriano E; Jiménez de Anta T Med Clin (Barc); 1997 Apr; 108(14):521-3. PubMed ID: 9190435 [TBL] [Abstract][Full Text] [Related]
10. Comparison of Bactec NR-660 and Signal systems. Rimmer K; Cabot M J Clin Pathol; 1988 Jun; 41(6):676-8. PubMed ID: 3133401 [TBL] [Abstract][Full Text] [Related]
11. A comparison of costs and effectiveness of the BACTEC NR-730 system and a conventional method of blood culture. Kumarasinghe G; Chow C; Bassett DC Southeast Asian J Trop Med Public Health; 1991 Jun; 22(2):254-61. PubMed ID: 1948288 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Bactec microbial detection system for culturing miscellaneous sterile body fluids. Akcam FZ; Yayli G; Uskun E; Kaya O; Demir C Res Microbiol; 2006 Jun; 157(5):433-6. PubMed ID: 16364602 [TBL] [Abstract][Full Text] [Related]
13. Comparative study of a non-radiometric BACTEC system and a conventional blood culture system in a clinical microbiology laboratory. Yew OF; Cheong YM; Zaidatul AR; Thanaletchimy N Malays J Pathol; 1995 Jun; 17(1):11-5. PubMed ID: 8906999 [TBL] [Abstract][Full Text] [Related]
14. [Evaluation of blood cultures in anaerobiosis]. García-Irure JJ; Recalde M; García-Lechuz JM; Perfecto B; Kutz M Enferm Infecc Microbiol Clin; 1994 Nov; 12(9):449-51. PubMed ID: 7811772 [TBL] [Abstract][Full Text] [Related]
15. [Comparison of 2 systems of blood culture: Signal and Bactec]. Croizé J; Cadoux B; Leclerc P; François P; Brion JP; Le Noc P Ann Biol Clin (Paris); 1989; 47(6):311-6. PubMed ID: 2675682 [TBL] [Abstract][Full Text] [Related]
16. Comparison of BACTEC automated blood culture system and conventional system in hospitalized pediatric patients. Chokephaibulkit K; Sitthitrai P; Wanprapa N; Chearskul S; Srifuengfung S; Pingwang B; Dhiraputra C J Med Assoc Thai; 1999 Oct; 82(10):1011-6. PubMed ID: 10561964 [TBL] [Abstract][Full Text] [Related]
17. Comparison between the BACTEC 9240 and the Pall eBDS system for detection of bacterial platelet concentrate contamination. Savini V; Balbinot A; Giancola R; Quaglietta A; Accorsi P; D'Antonio D; Iacone A Transfusion; 2009 Jun; 49(6):1217-23. PubMed ID: 19389034 [TBL] [Abstract][Full Text] [Related]
18. [Evaluation of the speed of 3 hemoculture systems to detect bacteria in the blood]. Climent C; Núñez ML; Sempere M; Gómez J; Ruiz J Enferm Infecc Microbiol Clin; 1994 Dec; 12(10):480-3. PubMed ID: 7865554 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of BACTEC MYCO/F Lytic medium for recovery of mycobacteria, fungi, and bacteria from blood. Fuller DD; Davis TE; Denys GA; York MK J Clin Microbiol; 2001 Aug; 39(8):2933-6. PubMed ID: 11474016 [TBL] [Abstract][Full Text] [Related]
20. Comparison of BACTEC MGIT 960 system and BACTEC 460 TB system for growth and detection of Mycobacteria from clinical specimens. Ganeswrie R; Chui CS; Balan S; Puthucheary SD Malays J Pathol; 2004 Dec; 26(2):99-103. PubMed ID: 16329561 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]