These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 25032758)

  • 1. Changes in the abutment-implant interface in Morse taper implant connections after mechanical cycling: a pilot study.
    Gehrke SA; Pereira Fde A
    Int J Oral Maxillofac Implants; 2014; 29(4):791-7. PubMed ID: 25032758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Removal Torque and Biofilm Accumulation at Two Dental Implant-Abutment Joints After Fatigue.
    Pereira J; Morsch CS; Henriques B; Nascimento RM; Benfatti CA; Silva FS; López-López J; Souza JC
    Int J Oral Maxillofac Implants; 2016; 31(4):813-9. PubMed ID: 27447147
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental research on the relationship between fit accuracy and fracture resistance of zirconia abutments.
    Sui X; Wei H; Wang D; Han Y; Deng J; Wang Y; Wang J; Yang J
    J Dent; 2014 Oct; 42(10):1353-9. PubMed ID: 24561040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.
    Alves DCC; de Carvalho PSP; Elias CN; Vedovatto E; Martinez EF
    Clin Oral Investig; 2016 Dec; 20(9):2437-2445. PubMed ID: 26895757
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Misfit of Three Different Implant-Abutment Connections Before and After Cyclic Load Application: An In Vitro Study.
    Gehrke SA; Delgado-Ruiz RA; Prados Frutos JC; Prados-Privado M; Dedavid BA; Granero Marín JM; Calvo Guirado JL
    Int J Oral Maxillofac Implants; 2017; 32(4):822-829. PubMed ID: 28708914
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments.
    de Oliveira Silva TS; Mendes Alencar SM; da Silva Valente V; de Moura CDVS
    J Prosthet Dent; 2017 May; 117(5):621-627. PubMed ID: 27881313
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of Removal Torque and Internal Surface Alterations in Frictional Morse Taper Connections After Mechanical Loading Associated or Not with Oral Biofilm.
    Asmarz HY; Magrin GL; Prado AM; Passoni BB; Magalhães Benfatti CA
    Int J Oral Maxillofac Implants; 2021; 36(3):492-501. PubMed ID: 34115063
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Load fatigue performance of conical implant-abutment connection: effect of torque level and interface junction.
    Gehrke SA; De Carvalho Serra R
    Minerva Stomatol; 2015 Feb; 64(1):1-7. PubMed ID: 25660589
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling.
    Jorge JR; Barao VA; Delben JA; Assuncao WG
    Int J Oral Maxillofac Implants; 2013; 28(2):415-22. PubMed ID: 23527343
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values.
    Smith NA; Turkyilmaz I
    J Prosthet Dent; 2014 Sep; 112(3):561-7. PubMed ID: 24656409
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wear of Morse taper and external hexagon implant joints after abutment removal.
    Prado AM; Pereira J; Silva FS; Henriques B; Nascimento RM; Benfatti CAM; López-López J; Souza JCM
    J Mater Sci Mater Med; 2017 May; 28(5):65. PubMed ID: 28321800
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Scanning Electron Microscopy Analysis of the Adaptation of Single-Unit Screw-Retained Computer-Aided Design/Computer-Aided Manufacture Abutments After Mechanical Cycling.
    Markarian RA; Galles DP; Gomes França FM
    Int J Oral Maxillofac Implants; 2018; 33(1):127–136. PubMed ID: 28632256
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic fatigue resistance of implant-abutment junction in an internally notched morse-taper oral implant: influence of abutment design.
    Cehreli MC; Akça K; Iplikçioğlu H; Sahin S
    Clin Oral Implants Res; 2004 Aug; 15(4):459-65. PubMed ID: 15248881
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The bacterial sealing capacity of morse taper implant-abutment systems in vitro.
    Ranieri R; Ferreira A; Souza E; Arcoverde J; Dametto F; Gade-Neto C; Seabra F; Sarmento C
    J Periodontol; 2015 May; 86(5):696-702. PubMed ID: 25658884
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Scanning electron microscopic evaluation of microgap size in Morse taper implants with straight and angled abutments.
    Costa MB; Ferreira LF; Marqueti AC; Takeshita WM; Trento CL
    Gen Dent; 2022; 70(6):34-39. PubMed ID: 36288073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded conical dental implants using synchrotron-based radiography.
    Rack T; Zabler S; Rack A; Riesemeier H; Nelson K
    Int J Oral Maxillofac Implants; 2013; 28(1):44-50. PubMed ID: 23377046
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of castable and premachined metal base abutment/implant interfaces before and after cyclical load.
    De Mori R; Ribeiro CF; da Silva-Concílio LR; Claro Neves AC
    Implant Dent; 2014 Apr; 23(2):212-7. PubMed ID: 24637531
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface.
    Cavusoglu Y; Akça K; Gürbüz R; Cehreli MC
    Int J Oral Maxillofac Implants; 2014; 29(2):338-43. PubMed ID: 24683559
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of the ITI Morse taper implant/abutment design with an internal modification.
    Ding TA; Woody RD; Higginbottom FL; Miller BH
    Int J Oral Maxillofac Implants; 2003; 18(6):865-72. PubMed ID: 14696662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of polishing process on torque loss ratio and microgap of selective laser melting abutment: an in vitro study.
    Zhong P; Deng L; Xu S; Cao Y
    BMC Oral Health; 2024 Sep; 24(1):1055. PubMed ID: 39251975
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.