154 related articles for article (PubMed ID: 25034778)
1. Diagnostic accuracy of screening MR imaging using unenhanced axial CISS and coronal T2WI for detection of small internal auditory canal lesions.
Abele TA; Besachio DA; Quigley EP; Gurgel RK; Shelton C; Harnsberger HR; Wiggins RH
AJNR Am J Neuroradiol; 2014 Dec; 35(12):2366-70. PubMed ID: 25034778
[TBL] [Abstract][Full Text] [Related]
2. MRI screening of the internal auditory canal: Is gadolinium necessary to detect intralabyrinthine schwannomas?
Valesano JC; Carr CM; Eckel LJ; Carlson ML; Lane JI
Am J Otolaryngol; 2018; 39(2):133-137. PubMed ID: 29273441
[TBL] [Abstract][Full Text] [Related]
3. Diagnostic accuracy of the constructive interference in steady state sequence alone for follow-up imaging of vestibular schwannomas.
Ozgen B; Oguz B; Dolgun A
AJNR Am J Neuroradiol; 2009 May; 30(5):985-91. PubMed ID: 19193761
[TBL] [Abstract][Full Text] [Related]
4. Detection of acoustic schwannoma: use of constructive interference in the steady state three-dimensional MR.
Stuckey SL; Harris AJ; Mannolini SM
AJNR Am J Neuroradiol; 1996 Aug; 17(7):1219-25. PubMed ID: 8871702
[TBL] [Abstract][Full Text] [Related]
5. Can MRI replace CT in evaluating semicircular canal dehiscence?
Browaeys P; Larson TL; Wong ML; Patel U
AJNR Am J Neuroradiol; 2013 Jul; 34(7):1421-7. PubMed ID: 23518357
[TBL] [Abstract][Full Text] [Related]
6. MR imaging of the inner ear: comparison of a three-dimensional fast spin-echo sequence with use of a dedicated quadrature-surface coil with a gadolinium-enhanced spoiled gradient-recalled sequence.
Naganawa S; Ito T; Fukatsu H; Ishigaki T; Nakashima T; Ichinose N; Kassai Y; Miyazaki M
Radiology; 1998 Sep; 208(3):679-85. PubMed ID: 9722845
[TBL] [Abstract][Full Text] [Related]
7. Diagnosis of small vestibular schwannomas using constructive interference steady state sequence.
Liudahl AA; Davis AB; Liudahl DS; Maley J; Policeni B; Hansen MR
Laryngoscope; 2018 Sep; 128(9):2128-2132. PubMed ID: 29392722
[TBL] [Abstract][Full Text] [Related]
8. Magnetic resonance findings in 92 acoustic neuromas.
Duvoisin B; Fernandes J; Doyon D; Denys A; Sterkers JM; Bobin S
Eur J Radiol; 1991; 13(2):96-102. PubMed ID: 1743199
[TBL] [Abstract][Full Text] [Related]
9. Pathology of the membranous labyrinth: comparison of T1- and T2-weighted and gadolinium-enhanced spin-echo and 3DFT-CISS imaging.
Casselman JW; Kuhweide R; Ampe W; Meeus L; Steyaert L
AJNR Am J Neuroradiol; 1993; 14(1):59-69. PubMed ID: 8427112
[TBL] [Abstract][Full Text] [Related]
10. MRI of inner ear and facial nerve pathology using 3D MP-RAGE and 3D CISS sequences.
Held P; Fellner C; Fellner F; Seitz J; Graf S; Hilbert M; Strutz J
Br J Radiol; 1997 Jun; 70(834):558-66. PubMed ID: 9227246
[TBL] [Abstract][Full Text] [Related]
11. Low-cost high-resolution fast spin-echo MR of acoustic schwannoma: an alternative to enhanced conventional spin-echo MR?
Allen RW; Harnsberger HR; Shelton C; King B; Bell DA; Miller R; Parkin JL; Apfelbaum RI; Parker D
AJNR Am J Neuroradiol; 1996 Aug; 17(7):1205-10. PubMed ID: 8871700
[TBL] [Abstract][Full Text] [Related]
12. Accuracy of single-sequence MRI for investigation of the fluid-filled spaces in the inner ear and cerebellopontine angle.
Lemmerling M; De Praeter G; Caemaert J; Van Cauwemberge P; De Reuck J; Vermeersch H; Kunnen M
Neuroradiology; 1999 Apr; 41(4):292-9. PubMed ID: 10344518
[TBL] [Abstract][Full Text] [Related]
13. Clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3T.
Kudo H; Inaoka T; Kitamura N; Nakatsuka T; Kasuya S; Kasai R; Tozawa M; Nakagawa K; Terada H
Magn Reson Imaging; 2013 Oct; 31(8):1309-17. PubMed ID: 23684241
[TBL] [Abstract][Full Text] [Related]
14. MRI screening for acoustic neuroma without gadolinium: value of 3DFT-CISS sequence.
Hermans R; Van der Goten A; De Foer B; Baert AL
Neuroradiology; 1997 Aug; 39(8):593-8. PubMed ID: 9272499
[TBL] [Abstract][Full Text] [Related]
15. Osteoma of the internal auditory canal mimicking vestibular schwannoma: case report and review of 17 recent cases.
Suzuki J; Takata Y; Miyazaki H; Yahata I; Tachibana Y; Kobayashi T; Kawase T; Katori Y
Tohoku J Exp Med; 2014 Jan; 232(1):63-8. PubMed ID: 24492629
[TBL] [Abstract][Full Text] [Related]
16. Is MRI Equal to CT in the Evaluation of Thin and Dehiscent Superior Semicircular Canals?
Spear SA; Jackson NM; Mehta R; Morel CE; Miller LS; Anderson D; Arriaga MA
Otol Neurotol; 2016 Feb; 37(2):167-70. PubMed ID: 26719960
[TBL] [Abstract][Full Text] [Related]
17. Screening protocol for MR imaging of the internal auditory canal.
Litt AW; Mirsky P; Berson BD; Kricheff II
J Comput Assist Tomogr; 1991; 15(6):930-3. PubMed ID: 1939770
[TBL] [Abstract][Full Text] [Related]
18. Detectability of Malignant Lesions by Whole-Body Magnetic Resonance Imaging Using Whole-Body Integrated Positron Emission Tomography/Magnetic Resonance Imaging.
Ishii S; Miyajima M; Suenaga H; Sugawara S; Nemoto A; Ukon N; Nambu T; Kubo H; Oriuchi N; Ito H
J Comput Assist Tomogr; 2019; 43(4):664-670. PubMed ID: 31259851
[TBL] [Abstract][Full Text] [Related]
19. Magnetic resonance examination of the inner ear and cerebellopontine angle in patients with vertigo and/or abnormal findings at vestibular testing.
Casselman JW; Kuhweide R; Dehaene I; Ampe W; Devlies F
Acta Otolaryngol Suppl; 1994; 513():15-27. PubMed ID: 8191885
[TBL] [Abstract][Full Text] [Related]
20. Diagnosis of internal derangement of the knee at 3.0-T MR imaging: 3D isotropic intermediate-weighted versus 2D sequences.
Jung JY; Yoon YC; Kwon JW; Ahn JH; Choe BK
Radiology; 2009 Dec; 253(3):780-7. PubMed ID: 19789228
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]