176 related articles for article (PubMed ID: 2503914)
1. Transcutaneous CO2 monitoring in adults with sleep-related breathing disorders.
Gislason T; Sandhagen B; Boman G
Ups J Med Sci; 1989; 94(2):171-81. PubMed ID: 2503914
[TBL] [Abstract][Full Text] [Related]
2. Superiority of transcutaneous CO2 over end-tidal CO2 measurement for monitoring respiratory failure in nonintubated patients: A pilot study.
Lermuzeaux M; Meric H; Sauneuf B; Girard S; Normand H; Lofaso F; Terzi N
J Crit Care; 2016 Feb; 31(1):150-6. PubMed ID: 26463320
[TBL] [Abstract][Full Text] [Related]
3. Transcutaneous and end-tidal carbon dioxide pressures should be measured during pediatric polysomnography.
Morielli A; Desjardins D; Brouillette RT
Am Rev Respir Dis; 1993 Dec; 148(6 Pt 1):1599-604. PubMed ID: 8256908
[TBL] [Abstract][Full Text] [Related]
4. Continuous non-invasive PCO
Schwarz SB; Windisch W; Magnet FS; Schmoor C; Karagiannidis C; Callegari J; Huttmann SE; Storre JH
Respirology; 2017 Nov; 22(8):1579-1584. PubMed ID: 28613389
[TBL] [Abstract][Full Text] [Related]
5. Comparison of arterial CO
Duyu M; Mocan Çağlar Y; Karakaya Z; Usta Aslan M; Yılmaz S; Ören Leblebici AN; Doğan Bektaş A; Bahar M; Yersel MN
J Clin Monit Comput; 2021 Feb; 35(1):101-111. PubMed ID: 32720231
[TBL] [Abstract][Full Text] [Related]
6. The accuracy of transcutaneous PCO2 in subjects with severe brain injury: a comparison with end-tidal PCO2.
Rosier S; Launey Y; Bleichner JP; Laviolle B; Jouve A; Malledant Y; Seguin P
Respir Care; 2014 Aug; 59(8):1242-7. PubMed ID: 24327740
[TBL] [Abstract][Full Text] [Related]
7. Comparison of noninvasive measurements of carbon dioxide tension during withdrawal from mechanical ventilation.
Healey CJ; Fedullo AJ; Swinburne AJ; Wahl GW
Crit Care Med; 1987 Aug; 15(8):764-8. PubMed ID: 3111790
[TBL] [Abstract][Full Text] [Related]
8. [The accuracy of transcutaneous carbon dioxide monitoring during laparoscopic surgery].
Nakamura A; Kanai M; Mizushima A; Katashima S; Miura K; Kawauchi Y; Kamiyama Y
Masui; 2003 Aug; 52(8):846-51. PubMed ID: 13677274
[TBL] [Abstract][Full Text] [Related]
9. The application of transcutaneous CO2 pressure monitoring in the anesthesia of obese patients undergoing laparoscopic bariatric surgery.
Liu S; Sun J; Chen X; Yu Y; Liu X; Liu C
PLoS One; 2014; 9(4):e91563. PubMed ID: 24699267
[TBL] [Abstract][Full Text] [Related]
10. Transcutaneous PTCCO
Spelten O; Fiedler F; Schier R; Wetsch WA; Hinkelbein J
J Clin Monit Comput; 2017 Feb; 31(1):153-158. PubMed ID: 26628269
[TBL] [Abstract][Full Text] [Related]
11. Comparison of arterial, end-tidal and transcutaneous PCO2 during moderate exercise and external CO2 loading in humans.
Hoffmann U; Essfeld D; Stegemann J
Eur J Appl Physiol Occup Physiol; 1990; 61(1-2):1-4. PubMed ID: 2127017
[TBL] [Abstract][Full Text] [Related]
12. Noninvasive monitoring of carbon dioxide: a comparison of the partial pressure of transcutaneous and end-tidal carbon dioxide with the partial pressure of arterial carbon dioxide.
Phan CQ; Tremper KK; Lee SE; Barker SJ
J Clin Monit; 1987 Jul; 3(3):149-54. PubMed ID: 3612214
[TBL] [Abstract][Full Text] [Related]
13. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
[TBL] [Abstract][Full Text] [Related]
14. End-tidal CO
Dicembrino M; Alejandra Barbieri I; Pereyra C; Leske V
Pediatr Pulmonol; 2021 Feb; 56(2):486-494. PubMed ID: 33382537
[TBL] [Abstract][Full Text] [Related]
15. Noninvasive carbon dioxide monitoring in pediatric patients undergoing laparoscopic surgery: transcutaneous vs. end-tidal techniques.
Wang W; Zhao Z; Tian X; Ma X; Xu L; Shang G
BMC Pediatr; 2023 Jan; 23(1):20. PubMed ID: 36639787
[TBL] [Abstract][Full Text] [Related]
16. Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep.
Sanders MH; Kern NB; Costantino JP; Stiller RA; Strollo PJ; Studnicki KA; Coates JA; Richards TJ
Chest; 1994 Aug; 106(2):472-83. PubMed ID: 7774323
[TBL] [Abstract][Full Text] [Related]
17. Estimation of arterial carbon dioxide by end-tidal and transcutaneous PCO2 measurements in ventilated children.
Sivan Y; Eldadah MK; Cheah TE; Newth CJ
Pediatr Pulmonol; 1992 Mar; 12(3):153-7. PubMed ID: 1641271
[TBL] [Abstract][Full Text] [Related]
18. Transcutaneous carbon dioxide during sleep-disordered breathing.
Rimpilä V; Hosokawa K; Huhtala H; Saaresranta T; Salminen AV; Polo O
Respir Physiol Neurobiol; 2015 Dec; 219():95-102. PubMed ID: 26474829
[TBL] [Abstract][Full Text] [Related]
19. Transcutaneous blood gas CO2 monitoring of induced ventilatory depression in mice.
Sahbaie P; Modanlou S; Gharagozlou P; Clark JD; Lameh J; Delorey TM
Anesth Analg; 2006 Sep; 103(3):620-5. PubMed ID: 16931671
[TBL] [Abstract][Full Text] [Related]
20. Transcutaneous PCO2 monitoring during laparoscopic cholecystectomy in pregnancy.
Bhavani-Shankar K; Steinbrook RA; Mushlin PS; Freiberger D
Can J Anaesth; 1998 Feb; 45(2):164-9. PubMed ID: 9512853
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]