These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 25041720)

  • 1. Tight glycemic control in the ICU - is the earth flat?
    Steil GM; Agus MS
    Crit Care; 2014 Jun; 18(3):159. PubMed ID: 25041720
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous glucose control in the ICU: report of a 2013 round table meeting.
    Wernerman J; Desaive T; Finfer S; Foubert L; Furnary A; Holzinger U; Hovorka R; Joseph J; Kosiborod M; Krinsley J; Mesotten D; Nasraway S; Rooyackers O; Schultz MJ; Van Herpe T; Vigersky RA; Preiser JC
    Crit Care; 2014 Jun; 18(3):226. PubMed ID: 25041718
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Using Continuous Glucose Monitoring Data and Detrended Fluctuation Analysis to Determine Patient Condition: A Review.
    Thomas F; Signal M; Chase JG
    J Diabetes Sci Technol; 2015 Jun; 9(6):1327-35. PubMed ID: 26134835
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Glucose control in the intensive care unit.
    Fahy BG; Sheehy AM; Coursin DB
    Crit Care Med; 2009 May; 37(5):1769-76. PubMed ID: 19325461
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Near-Continuous Glucose Monitoring Makes Glycemic Control Safer in ICU Patients.
    Preiser JC; Lheureux O; Thooft A; Brimioulle S; Goldstein J; Vincent JL
    Crit Care Med; 2018 Aug; 46(8):1224-1229. PubMed ID: 29677007
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous glucose monitors and the burden of tight glycemic control in critical care: can they cure the time cost?
    Signal M; Pretty CG; Chase JG; Le Compte A; Shaw GM
    J Diabetes Sci Technol; 2010 May; 4(3):625-35. PubMed ID: 20513329
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous glucose monitors prove highly accurate in critically ill children.
    Bridges BC; Preissig CM; Maher KO; Rigby MR
    Crit Care; 2010; 14(5):R176. PubMed ID: 20925914
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous glucose monitoring in the ICU: clinical considerations and consensus.
    Krinsley JS; Chase JG; Gunst J; Martensson J; Schultz MJ; Taccone FS; Wernerman J; Bohe J; De Block C; Desaive T; Kalfon P; Preiser JC
    Crit Care; 2017 Jul; 21(1):197. PubMed ID: 28756769
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [MODERN TECHNOLOGIES FOR MONITORING AND CORRECTION OF BLOOD GLUCOSE LEVELS IN PATIENTS IN THE INTENSIVE CARE UNIT].
    Nikoda VV; Bondarenko AV; Lishova EA; Ragozin AK
    Anesteziol Reanimatol; 2015; 60(2):62-7. PubMed ID: 26148367
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Insulin treatment guided by subcutaneous continuous glucose monitoring compared to frequent point-of-care measurement in critically ill patients: a randomized controlled trial.
    Boom DT; Sechterberger MK; Rijkenberg S; Kreder S; Bosman RJ; Wester JP; van Stijn I; DeVries JH; van der Voort PH
    Crit Care; 2014 Aug; 18(4):453. PubMed ID: 25139609
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood glucose measurements in critically ill patients.
    Van Herpe T; Mesotten D
    J Diabetes Sci Technol; 2012 Jan; 6(1):22-8. PubMed ID: 22401319
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical practice. Glycemic control in the ICU.
    Kavanagh BP; McCowen KC
    N Engl J Med; 2010 Dec; 363(26):2540-6. PubMed ID: 21175316
    [No Abstract]   [Full Text] [Related]  

  • 13. Glycemic control in the critically ill: What have we learned since NICE-SUGAR?
    Krinsley JS
    Hosp Pract (1995); 2015; 43(3):191-7. PubMed ID: 26224425
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial.
    Holzinger U; Warszawska J; Kitzberger R; Wewalka M; Miehsler W; Herkner H; Madl C
    Diabetes Care; 2010 Mar; 33(3):467-72. PubMed ID: 20007948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis: Continuous glucose monitoring during intensive insulin therapy.
    Mraovic B
    J Diabetes Sci Technol; 2009 Jul; 3(4):960-3. PubMed ID: 20144346
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sweet Spot: Glucose Control in the Intensive Care Unit.
    van Hooijdonk RT; Mesotten D; Krinsley JS; Schultz MJ
    Semin Respir Crit Care Med; 2016 Feb; 37(1):57-67. PubMed ID: 26820275
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-time continuous glucose monitoring versus conventional glucose monitoring in critically ill patients: a systematic review study protocol.
    Zhu W; Jiang L; Jiang S; Ma Y; Zhang M
    BMJ Open; 2015 Jan; 5(1):e006579. PubMed ID: 25616512
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stochastic targeted (STAR) glycemic control: design, safety, and performance.
    Evans A; Le Compte A; Tan CS; Ward L; Steel J; Pretty CG; Penning S; Suhaimi F; Shaw GM; Desaive T; Chase JG
    J Diabetes Sci Technol; 2012 Jan; 6(1):102-15. PubMed ID: 22401328
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Value of continuous glucose monitoring for minimizing severe hypoglycemia during tight glycemic control.
    Steil GM; Langer M; Jaeger K; Alexander J; Gaies M; Agus MS
    Pediatr Crit Care Med; 2011 Nov; 12(6):643-8. PubMed ID: 21499183
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients.
    Plank J; Blaha J; Cordingley J; Wilinska ME; Chassin LJ; Morgan C; Squire S; Haluzik M; Kremen J; Svacina S; Toller W; Plasnik A; Ellmerer M; Hovorka R; Pieber TR
    Diabetes Care; 2006 Feb; 29(2):271-6. PubMed ID: 16443872
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.