These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 25052344)

  • 1. Capacitive measurement of ECG for ubiquitous healthcare.
    Lim YG; Lee JS; Lee SM; Lee HJ; Park KS
    Ann Biomed Eng; 2014 Nov; 42(11):2218-27. PubMed ID: 25052344
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Capacitive driven-right-leg grounding in Indirect-contact ECG measurement.
    Lim YG; Chung GS; Park KS
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1250-3. PubMed ID: 21095911
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Insulating electrodes: a review on biopotential front ends for dielectric skin-electrode interfaces.
    Spinelli E; Haberman M
    Physiol Meas; 2010 Oct; 31(10):S183-98. PubMed ID: 20834109
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preamplifiers for non-contact capacitive biopotential measurements.
    Peng G; Ignjatovic Z; Bocko MF
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1482-5. PubMed ID: 24109979
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of human body communication-based wearable ECG with capacitive coupling electrodes.
    Sakuma J; Anzai D; Wang J
    Healthc Technol Lett; 2016 Sep; 3(3):222-225. PubMed ID: 27733931
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.
    Lee JS; Heo J; Lee WK; Lim YG; Kim YH; Park KS
    Sensors (Basel); 2014 Aug; 14(8):14732-43. PubMed ID: 25120162
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noise Model of Capacitive and Textile Capacitive Noncontact Electrodes for Bioelectric Applications.
    Asl SN; Oehler M; Schilling M
    IEEE Trans Biomed Circuits Syst; 2018 Aug; 12(4):851-859. PubMed ID: 29994266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A capacitive electrode with fast recovery feature.
    Spinelli E; Haberman M; García P; Guerrero F
    Physiol Meas; 2012 Aug; 33(8):1277-88. PubMed ID: 22813845
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-contact electrocardiogram measuring method based on capacitance coupling electrodes with ultra-high input impedance.
    Li J; Wang Y; Li C; Xu Z; Zhao Z; Raza SA; Wang Y
    Rev Sci Instrum; 2022 Mar; 93(3):034101. PubMed ID: 35365001
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impedance measurement system for determination of capacitive electrode coupling.
    Eilebrecht B; Willkomm J; Pohl A; Wartzek T; Leonhardt S
    IEEE Trans Biomed Circuits Syst; 2013 Oct; 7(5):682-9. PubMed ID: 24232629
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple and reproducible capacitive electrode.
    Spinelli E; Guerrero F; García P; Haberman M
    Med Eng Phys; 2016 Mar; 38(3):286-9. PubMed ID: 26792172
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of electrocardiograms in a bath through tap water utilizing capacitive coupling electrodes placed outside the bathtub wall.
    Motoi K; Yamakoshi Y; Yamakoshi T; Sakai H; Tanaka N; Yamakoshi KI
    Biomed Eng Online; 2017 Jan; 16(1):12. PubMed ID: 28086891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors.
    Choi M; Jeong JJ; Kim SH; Kim SW
    Sensors (Basel); 2016 May; 16(5):. PubMed ID: 27196910
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comments on "A novel high input impedance front-end for capacitive biopotential measurement".
    Pallàs Areny R
    Med Biol Eng Comput; 2020 Feb; 58(2):267-269. PubMed ID: 31834611
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel Stable Capacitive Electrocardiogram Measurement System.
    Chen CC; Lin SY; Chang WY
    Sensors (Basel); 2021 May; 21(11):. PubMed ID: 34070412
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Closed-Loop Control of Humidification for Artifact Reduction in Capacitive ECG Measurements.
    Leicht L; Eilebrecht B; Weyer S; Leonhardt S; Teichmann D
    IEEE Trans Biomed Circuits Syst; 2017 Apr; 11(2):300-313. PubMed ID: 28129182
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.
    Lee SM; Sim KS; Kim KK; Lim YG; Park KS
    Med Biol Eng Comput; 2010 May; 48(5):447-57. PubMed ID: 20361268
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Wireless ECG measurement system with capacitive coupling].
    Aleksandrowicz A; Walter M; Leonhardt S
    Biomed Tech (Berl); 2007 Apr; 52(2):185-92. PubMed ID: 17408378
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a wearable multi-frequency impedance cardiography device.
    Weyer S; Menden T; Leicht L; Leonhardt S; Wartzek T
    J Med Eng Technol; 2015 Feb; 39(2):131-7. PubMed ID: 25559781
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CNT/PDMS composite flexible dry electrodes for long-term ECG monitoring.
    Jung HC; Moon JH; Baek DH; Lee JH; Choi YY; Hong JS; Lee SH
    IEEE Trans Biomed Eng; 2012 May; 59(5):1472-9. PubMed ID: 22410324
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.