These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 25070385)

  • 1. Transthoracic echocardiography as an alternative major guidance to angiography during transcatheter closure of patent ductus arteriosus: technical feasibility and clinical relevance.
    Chen W; Yan X; Huang Y; Sun X; Zhong L; Li J; Chen H; Zhong H; Chen L
    Pediatr Cardiol; 2015 Jan; 36(1):14-9. PubMed ID: 25070385
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Advances in interventional occlusion of persistent ductus arteriosus: comparison of results using different occlusion devices].
    Koch A; Hofbeck M; Buheitel G; Gerling S; Rauch R; Singer H
    Z Kardiol; 2001 Feb; 90(2):120-6. PubMed ID: 11263001
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prospective evaluation of the feasibility, safety, and efficacy of Cocoon Duct Occluder for transcatheter closure of large patent ductus arteriosus: A single-center study with short- and medium-term follow-up results.
    Sinha SK; Razi M; Pandey RN; Kumar P; Krishna V; Jha MJ; Mishra V; Asif M; Abdali N; Tewari P; Thakur R; Pandey U; Varma CM
    Anatol J Cardiol; 2017 Nov; 18(5):321-327. PubMed ID: 29145233
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closure of the patent ductus arteriosus with the Amplatzer Duct Occluder II: a clinical experience.
    Karagöz T; Akin A; Ertuğrul I; Aykan HH; Alehan D; Ozer S; Ozkutlu S
    Acta Cardiol; 2012 Dec; 67(6):675-80. PubMed ID: 23393938
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of transvenous versus transthoracic catheter-based device closure of patent ductus arteriosus with amplatzer duct occluder.
    Chen LY; Cai P; Cheng ZD; Zhang ZB; Chen DZ; Cao H; Qiu HF; Chen LL
    J Invasive Cardiol; 2013 Oct; 25(10):502-6. PubMed ID: 24088423
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Transcatheter closure of patent ductus arteriosus with the new Amplatzer Duct OccluderII].
    Ji W; Li F; Gao W; Yu ZQ; Huang MR; Fu LJ; Guo Y; Zhao PJ; Liu TL; Zhang YQ; Chen YW
    Zhonghua Er Ke Za Zhi; 2013 Feb; 51(2):126-9. PubMed ID: 23527979
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by amplatzer ductal occluder additional size-ADOIIAS.
    Morville P; Akhavi A
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):612-617. PubMed ID: 28471089
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Long-term clinical experience with Amplatzer Ductal Occluder II for closure of the persistent arterial duct in children.
    Kang SL; Morgan G; Forsey J; Tometzki A; Martin R
    Catheter Cardiovasc Interv; 2014 Jun; 83(7):1102-8. PubMed ID: 24403100
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical evaluation of the new Amplatzer duct occluder II for patent arterial duct occlusion.
    Bhole V; Miller P; Mehta C; Stumper O; Reinhardt Z; De Giovanni JV
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):762-9. PubMed ID: 19522000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Percutaneous device closure of pediatirc patent ductus arteriosus through femoral artery guidance by transthoracic echocardiography without radiation and contrast agents.
    Ye Z; Li Z; Yi H; Zhu Y; Sun Y; Li P; Ma N
    J Cardiothorac Surg; 2020 May; 15(1):107. PubMed ID: 32448306
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Percutaneous closure of patent ductus arteriosus: short term results].
    Kaya Y; Bulut MO; Yurtdaş M; Karakurt A; Güvenç TS; Söylemez N; Güler A; Gönüllü E; Ceylan Y; Akdemir R
    Turk Kardiyol Dern Ars; 2013 Jun; 41(4):310-8. PubMed ID: 23760118
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Echocardiographic versus Angiographic Measurement of the Patent Ductus Arteriosus in Extremely Low Birth Weight Infants and the Utility of Echo Guidance for Transcatheter Closure.
    Paudel G; Johnson JN; Philip R; Tailor N; Fahnhorst S; Briceno-Medina M; Stecchi N; Waller BR; Sathanandam S
    J Am Soc Echocardiogr; 2021 Oct; 34(10):1086-1094. PubMed ID: 34139301
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the results of transcatheter closure of patent ductus arteriosus with newer Amplatzer devices.
    Liddy S; Oslizlok P; Walsh KP
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):253-9. PubMed ID: 23427043
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results.
    Gu X; Zhang Q; Sun H; Fei J; Zhang X; Kutryk MJ
    Congenit Heart Dis; 2017 May; 12(3):289-293. PubMed ID: 27874259
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardi-O-Fix duct occluder versus Amplatzer duct occluder for closure of patent ductus arteriosus.
    Celebi A; Demir IH; Saritaş T; Dedeoğlu R; Yucel IK; Demir F; Erdem A
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):961-7. PubMed ID: 23592558
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transcatheter Closure of Patent Ductus Arteriosus in Adolescents and Adults: A Case Series.
    Putra ST; Djer MM; Idris NS; Sastroasmoro S
    Acta Med Indones; 2016 Oct; 48(4):314-319. PubMed ID: 28143993
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous closure of a moderate to large tubular or elongated patent ductus arteriosus in children younger than 3 years: is the ADO II appropriate?
    Kumar SM; Subramanian V; Bijulal S; Krishnamoorthy KM; Sivasankaran S; Tharakan JA
    Pediatr Cardiol; 2013 Oct; 34(7):1661-7. PubMed ID: 23591801
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?
    Godart F; Houeijeh A; Domanski O; Guillaume MP; Brard M; Lucron H
    Int J Cardiol; 2018 Jun; 261():54-57. PubMed ID: 29551254
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I?
    Baykan A; Narin N; Özyurt A; Argun M; Pamukçu Ö; Onan SH; Sezer S; Baykan Z; Üzüm K
    Anatol J Cardiol; 2015 Mar; 15(3):242-7. PubMed ID: 25333978
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter Closure of Patent Ductus Arteriosus in Children with the Occlutech Duct Occluder.
    Bilici M; Demir F; Akın A; Türe M; Balık H; Kuyumcu M
    Pediatr Cardiol; 2017 Dec; 38(8):1598-1605. PubMed ID: 28828684
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.