BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 25073632)

  • 1. Education and Imaging. Gastroenterology: acute mucosal injury of esophagus and stomach induced by sodium picosulfate/magnesium citrate for bowel preparation.
    Suh JP; Choi YS; Lee SH
    J Gastroenterol Hepatol; 2014 Aug; 29(8):1571. PubMed ID: 25073632
    [No Abstract]   [Full Text] [Related]  

  • 2. Severe hyponatremia secondary to preparation for colonoscopy with sodium picosulfate/magnesium citrate.
    Azcune Echeverria O
    Rev Esp Enferm Dig; 2019 Mar; 111(3):249. PubMed ID: 30511577
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The rapid development of hyponatraemia and seizures in an elderly patient following sodium picosulfate/magnesium citrate (Picolax).
    Dillon CE; Laher MS
    Age Ageing; 2009 Jul; 38(4):487. PubMed ID: 19406975
    [No Abstract]   [Full Text] [Related]  

  • 4. Clenpiq--a low-volume sodium picosulfate-based colonoscopy preparation.
    Med Lett Drugs Ther; 2018 May; 60(1547):84-86. PubMed ID: 29913466
    [No Abstract]   [Full Text] [Related]  

  • 5. Symptomatic Hyponatremia after Bowel Preparation: Report of Two Cases and Literature Review.
    Costa JM; Soares JB
    Acta Med Port; 2017 Nov; 30(11):824-826. PubMed ID: 29279076
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy and tolerability of 2-L polyethylene glycol with ascorbic acid versus sodium picosulfate with magnesium citrate: a randomized controlled trial.
    Seo SI; Kang JG; Kim HS; Jang MK; Kim HY; Shin WG
    Int J Colorectal Dis; 2018 May; 33(5):541-548. PubMed ID: 29497812
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Polyethylene glycol plus ascorbic acid is as effective as sodium picosulfate with magnesium citrate for bowel preparation: A randomized trial.
    Choi HS; Chung JW; Lee JW; Lim MY; Park DK; Kim YJ; Kwon KA; Kim JH
    J Dig Dis; 2016 Apr; 17(4):268-73. PubMed ID: 26945825
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Observational multicentric study to evaluate efficacy, adverse effects and acceptance of bowel cleansing prior to colonoscopy with sodium picosulfate / magnesium citrate formulation CitraFleet®.
    Janisch HD; Koppold B; Deissler H; Riemann JF
    Z Gastroenterol; 2016 Jan; 54(1):19-25. PubMed ID: 26751113
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Superiority of a Split-dose Regimen of Sodium Picosulfate/Magnesium Citrate (SPMC) in Comparison to a Prior-day Schedule (AM/PM) for Colonoscopy Preparation. A Randomized Single-blinded Study.
    Schulz C; Müller J; Sauter J; Miehlke S; Schmöcker C; Hartmann D; Malfertheiner P; Badiola C
    J Gastrointestin Liver Dis; 2016 Sep; 25(3):295-302. PubMed ID: 27689192
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Randomized controlled trial comparing efficacy and acceptability of split- and standard-dose sodium picosulfate plus magnesium citrate for bowel cleansing prior to colonoscopy.
    Manes G; Repici A; Hassan C;
    Endoscopy; 2014 Aug; 46(8):662-9. PubMed ID: 25019969
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Time for individualized colonoscopy bowel-prep regimens? A randomized controlled trial comparing sodium picosulphate and magnesium citrate versus 4-liter split-dose polyethylene glycol.
    Voiosu T; Ratiu I; Voiosu A; Iordache T; Schipor A; Baicus C; Sporea I; Voiosu R
    J Gastrointestin Liver Dis; 2013 Jun; 22(2):129-34. PubMed ID: 23799210
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Randomized controlled trial of low-volume bowel preparation agents for colonic bowel preparation: 2-L polyethylene glycol with ascorbic acid versus sodium picosulfate with magnesium citrate.
    Jeon SR; Kim HG; Lee JS; Kim JO; Lee TH; Cho JH; Kim YH; Cho JY; Lee JS
    Int J Colorectal Dis; 2015 Feb; 30(2):251-8. PubMed ID: 25410648
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 'Pico-Bello-Klean study': effectiveness and patient tolerability of bowel preparation agents sodium picosulphate-magnesium citrate and polyethylene glycol before colonoscopy. A single-blinded randomized trial.
    Munsterman ID; Cleeren E; van der Ploeg T; Brohet R; van der Hulst R
    Eur J Gastroenterol Hepatol; 2015 Jan; 27(1):29-38. PubMed ID: 25426978
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A possible troponin I leak arising from bowel preparation for elective colonoscopy - are there more implications than observed?
    George AT; Allison M; Swarnkar KJ
    Colorectal Dis; 2010 Mar; 12(3):270-1. PubMed ID: 19548902
    [No Abstract]   [Full Text] [Related]  

  • 15. A randomized trial to compare the efficacy and tolerability of sodium picosulfate-magnesium citrate solution vs. 4 L polyethylene glycol solution as a bowel preparation for colonoscopy.
    Muñoz-Navas M; Calleja JL; Payeras G; Hervás AJ; Abreu LE; Orive V; Menchén PL; Bordas JM; Armengol JR; Carretero C; Beltrán VP; Alonso-Abreu I; Manteca R; Parra-Blanco A; Carballo F; Herrerías JM; Badiola C
    Int J Colorectal Dis; 2015 Oct; 30(10):1407-16. PubMed ID: 26179377
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Severe rhabdomyolysis and hyponatremia induced by picosulfate and bisacodyl during the preparation of colonoscopy.
    Más A; Chillarón JJ; Esteve E; Navalpotro I; Supervía A
    Rev Esp Enferm Dig; 2013 Mar; 105(3):180-1. PubMed ID: 23735032
    [No Abstract]   [Full Text] [Related]  

  • 17. Bowel preparation with sodium picosulfate was linked to hyponatremia compared with polyethylene glycol.
    Morgan D
    Ann Intern Med; 2014 Jul; 161(2):JC12. PubMed ID: 25023266
    [No Abstract]   [Full Text] [Related]  

  • 18. [Split-dose sodium picosulphate/magnesium citrate for morning colonoscopies performed 2 to 6 hours after fluid intake].
    Martín-Noguerol E; González-Santiago JM; Martínez-Alcalá C; Vinagre-Rodríguez G; Hernández-Alonso M; Dueñas-Sadornil C; Pérez-Gallardo B; Mateos-Rodríguez JM; Fernández-Bermejo M; Molina-Infante J
    Gastroenterol Hepatol; 2013 Apr; 36(4):254-60. PubMed ID: 23537750
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hyponatremia and sodium picosulfate bowel preparations in older adults.
    Weir MA; Fleet JL; Vinden C; Shariff SZ; Liu K; Song H; Jain AK; Gandhi S; Clark WF; Garg AX
    Am J Gastroenterol; 2014 May; 109(5):686-94. PubMed ID: 24589671
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Preparation of colonoscopy: well tolerable combination preparation admitted in Germany].
    Schirin-Sokhan R; Trautwein C
    MMW Fortschr Med; 2009 Sep; 151(39):40. PubMed ID: 19831195
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.