These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 25075897)

  • 1. Diagnostic shortcomings of magnetic resonance arthrography to evaluate partial rotator cuff tears in adolescents.
    Edmonds EW; Eisner EA; Kruk PG; Roocroft JH; Dwek JD
    J Pediatr Orthop; 2015 Jun; 35(4):407-11. PubMed ID: 25075897
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation.
    Waldt S; Bruegel M; Mueller D; Holzapfel K; Imhoff AB; Rummeny EJ; Woertler K
    Eur Radiol; 2007 Feb; 17(2):491-8. PubMed ID: 16969638
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tears of the supraspinatus tendon: assessment with indirect magnetic resonance arthrography in 67 patients with arthroscopic correlation.
    Van Dyck P; Gielen JL; Veryser J; Weyler J; Vanhoenacker FM; Van Glabbeek F; De Weerdt W; Maas M; van der Woude HJ; Parizel PM
    Acta Radiol; 2009 Nov; 50(9):1057-63. PubMed ID: 19863417
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rotator cuff tears noncontrast MRI compared to MR arthrography.
    Lee JH; Yoon YC; Jung JY; Yoo JC
    Skeletal Radiol; 2015 Dec; 44(12):1745-54. PubMed ID: 26260536
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.
    Brockmeyer M; Schmitt C; Haupert A; Kohn D; Lorbach O
    Arch Orthop Trauma Surg; 2017 Dec; 137(12):1719-1724. PubMed ID: 28942510
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.
    Lee JH; Yoon YC; Jee S
    Acta Radiol; 2015 Jun; 56(6):720-6. PubMed ID: 24938663
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effectiveness of multidetector computed tomography arthrography for the diagnosis of shoulder pathology: comparison with magnetic resonance imaging with arthroscopic correlation.
    Oh JH; Kim JY; Choi JA; Kim WS
    J Shoulder Elbow Surg; 2010 Jan; 19(1):14-20. PubMed ID: 19556150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparisons of the various partial-thickness rotator cuff tears on MR arthrography and arthroscopic correlation.
    Chun KA; Kim MS; Kim YJ
    Korean J Radiol; 2010; 11(5):528-35. PubMed ID: 20808696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of high-resolution ultrasound and magnetic resonance arthrography of the shoulder in patients with sports-related shoulder injuries.
    Wengert GJ; Schmutzer M; Bickel H; Sora MC; Polanec SH; Weber M; Schueller-Weidekamm C
    PLoS One; 2019; 14(9):e0222783. PubMed ID: 31545834
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears.
    Lee JH; Yoon YC; Jee S; Kwon JW; Cha JG; Yoo JC
    Korean J Radiol; 2014; 15(6):771-80. PubMed ID: 25469089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of rotator cuff tendon tears: comparison of multidetector CT arthrography and 1.5-T MR arthrography.
    Omoumi P; Bafort AC; Dubuc JE; Malghem J; Vande Berg BC; Lecouvet FE
    Radiology; 2012 Sep; 264(3):812-22. PubMed ID: 22919041
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reproducibility and reliability of subscapularis tendon assessment using CT-arthrography.
    Szymanski C; Staquet V; Deladerrière JY; Vervoort T; Audebert S; Maynou C
    Orthop Traumatol Surg Res; 2013 Feb; 99(1):2-9. PubMed ID: 23245986
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prognostic Factors Affecting Rotator Cuff Healing After Arthroscopic Repair in Small to Medium-sized Tears.
    Park JS; Park HJ; Kim SH; Oh JH
    Am J Sports Med; 2015 Oct; 43(10):2386-92. PubMed ID: 26286879
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fosbury flop tear of the rotator cuff: diagnostic assessment with magnetic resonance arthrography.
    Kolo FC; Schwitzguébel AJ; Kourhani A; Denard PJ; Charbonnier C; Lädermann A
    Br J Radiol; 2017 Aug; 90(1077):20170146. PubMed ID: 28707534
    [TBL] [Abstract][Full Text] [Related]  

  • 15. MR arthrographic depiction of tears of the rotator cuff: benefit of abduction and external rotation of the arm.
    Tirman PF; Bost FW; Steinbach LS; Mall JC; Peterfy CG; Sampson TG; Sheehan WE; Forbes JR; Genant HK
    Radiology; 1994 Sep; 192(3):851-6. PubMed ID: 8058959
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of saline and gadolinium shoulder MR arthrography to arthroscopy.
    Singer AD; Rosenthal J; Umpierrez M; Guo Y; Gonzalez F; Wagner E
    Skeletal Radiol; 2020 Apr; 49(4):625-633. PubMed ID: 31773187
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The clinical results of arthroscopic transtendinous repair of grade III partial articular-sided supraspinatus tendon tears.
    Duralde XA; McClelland WB
    Arthroscopy; 2012 Feb; 28(2):160-8. PubMed ID: 22078003
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Indirect MR arthrography of the shoulder: use of abduction and external rotation to detect full- and partial-thickness tears of the supraspinatus tendon.
    Herold T; Bachthaler M; Hamer OW; Hente R; Feuerbach S; Fellner C; Strotzer M; Lenhart M; Paetzel C
    Radiology; 2006 Jul; 240(1):152-60. PubMed ID: 16709790
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: accuracy, and inter- and intra-observer agreements.
    Jung JY; Jee WH; Chun HJ; Ahn MI; Kim YS
    Acta Radiol; 2010 Mar; 51(2):194-201. PubMed ID: 20001474
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Shoulder ultrasonography versus arthroscopy for the detection of rotator cuff tears: analysis of errors.
    Singisetti K; Hinsche A
    J Orthop Surg (Hong Kong); 2011 Apr; 19(1):76-9. PubMed ID: 21519083
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.