BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 25079252)

  • 1. Response of plastic scintillators to low-energy photons.
    Peralta L; Rêgo F
    Phys Med Biol; 2014 Aug; 59(16):4621-33. PubMed ID: 25079252
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of the energy dependence of the BC-408 plastic scintillation detector in medium energy x-ray beams.
    Yücel H; Çubukçu Ş; Uyar E; Engin Y
    Phys Med Biol; 2014 Nov; 59(22):6749-58. PubMed ID: 25327627
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.
    Wang LL; Klein D; Beddar AS
    Med Phys; 2010 Oct; 37(10):5279-86. PubMed ID: 21089762
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
    Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
    Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.
    Wang LL; Beddar S
    Med Phys; 2011 Mar; 38(3):1596-9. PubMed ID: 21520871
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Plastic scintillator response to low-energy photons.
    Williamson JF; Dempsey JF; Kirov AS; Monroe JI; Binns WR; Hedtjärn H
    Phys Med Biol; 1999 Apr; 44(4):857-71. PubMed ID: 10232801
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
    Beddar AS; Briere TM; Mourtada FA; Vassiliev ON; Liu HH; Mohan R
    Med Phys; 2005 May; 32(5):1265-9. PubMed ID: 15984678
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers.
    Teymurazyan A; Pang G
    Med Phys; 2012 Mar; 39(3):1518-29. PubMed ID: 22380384
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.
    Kim Y; Yoo H; Kim C; Lim KT; Moon M; Kim J; Cho G
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):187-90. PubMed ID: 26538616
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
    Chow JC; Jiang R
    Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo calculations of spectra and interaction probabilities for photons in liquid scintillators for use in the standardization of radionuclides.
    Zimmerman BE
    Appl Radiat Isot; 2006; 64(10-11):1492-8. PubMed ID: 16567098
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of intrinsic energy dependence of point-like inorganic scintillation detector in brachytherapy.
    Georgi P; Tedgren ÅC; Persson L; Johansen JG
    Med Phys; 2024 Jul; 51(7):5059-5069. PubMed ID: 38197459
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
    Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
    Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Water-equivalent one-dimensional scintillating fiber-optic dosimeter for measuring therapeutic photon beam.
    Moon J; Jang KW; Yoo WJ; Han KT; Park JY; Lee B
    Appl Radiat Isot; 2012 Nov; 70(11):2627-30. PubMed ID: 22944534
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2006 May; 51(10):2549-66. PubMed ID: 16675869
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
    Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.
    Guillot M; Gingras L; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2011 Apr; 38(4):2140-50. PubMed ID: 21626947
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.