176 related articles for article (PubMed ID: 25080895)
21. Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants.
Palmquist A; Jolic M; Hryha E; Shah FA
Acta Biomater; 2023 Jan; 156():125-145. PubMed ID: 35675890
[TBL] [Abstract][Full Text] [Related]
22. Revival of pure titanium for dynamically loaded porous implants using additive manufacturing.
Wauthle R; Ahmadi SM; Amin Yavari S; Mulier M; Zadpoor AA; Weinans H; Van Humbeeck J; Kruth JP; Schrooten J
Mater Sci Eng C Mater Biol Appl; 2015 Sep; 54():94-100. PubMed ID: 26046272
[TBL] [Abstract][Full Text] [Related]
23. Additive manufactured porous biomaterials targeting orthopedic implants: A suitable combination of mechanical, physical and topological properties.
Bartolomeu F; Dourado N; Pereira F; Alves N; Miranda G; Silva FS
Mater Sci Eng C Mater Biol Appl; 2020 Feb; 107():110342. PubMed ID: 31761155
[TBL] [Abstract][Full Text] [Related]
24. In vitro and in vivo comparisons of the porous Ti6Al4V alloys fabricated by the selective laser melting technique and a new sintering technique.
Li J; Li Z; Shi Y; Wang H; Li R; Tu J; Jin G
J Mech Behav Biomed Mater; 2019 Mar; 91():149-158. PubMed ID: 30579112
[TBL] [Abstract][Full Text] [Related]
25. Modification of titanium alloy surfaces for percutaneous implants by covalently attaching laminin.
Gordon DJ; Bhagawati DD; Pendegrass CJ; Middleton CA; Blunn GW
J Biomed Mater Res A; 2010 Aug; 94(2):586-93. PubMed ID: 20198691
[TBL] [Abstract][Full Text] [Related]
26. Electrochemical, Tribological and Biocompatible Performance of Electron Beam Modified and Coated Ti6Al4V Alloy.
Nikolova M; Ormanova M; Nikolova V; Apostolova MD
Int J Mol Sci; 2021 Jun; 22(12):. PubMed ID: 34198700
[TBL] [Abstract][Full Text] [Related]
27. Micro- to Macroroughness of Additively Manufactured Titanium Implants in Terms of Coagulation and Contact Activation.
Klingvall Ek R; Hong J; Thor A; Bäckström M; Rännar LE
Int J Oral Maxillofac Implants; 2017; 32(3):565-574. PubMed ID: 28494040
[TBL] [Abstract][Full Text] [Related]
28. Photofunctionalization increases the bioactivity and osteoconductivity of the titanium alloy Ti6Al4V.
Minamikawa H; Ikeda T; Att W; Hagiwara Y; Hirota M; Tabuchi M; Aita H; Park W; Ogawa T
J Biomed Mater Res A; 2014 Oct; 102(10):3618-30. PubMed ID: 24248891
[TBL] [Abstract][Full Text] [Related]
29. Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: Trabecular titanium.
Marin E; Fusi S; Pressacco M; Paussa L; Fedrizzi L
J Mech Behav Biomed Mater; 2010 Jul; 3(5):373-81. PubMed ID: 20416551
[TBL] [Abstract][Full Text] [Related]
30. Bioactive materials driven primary stability on titanium biocomposites.
Dantas TA; Abreu CS; Costa MM; Miranda G; Silva FS; Dourado N; Gomes JR
Mater Sci Eng C Mater Biol Appl; 2017 Aug; 77():1104-1110. PubMed ID: 28531984
[TBL] [Abstract][Full Text] [Related]
31. Dermal fibroblast and epidermal keratinocyte functionality on titania nanotube arrays.
Smith BS; Yoriya S; Johnson T; Popat KC
Acta Biomater; 2011 Jun; 7(6):2686-96. PubMed ID: 21414425
[TBL] [Abstract][Full Text] [Related]
32. Osteoblast response to plasma-spray porous Ti6Al4V coating on substrates of identical alloy.
Saldaña L; González-Carrasco JL; Rodríguez M; Munuera L; Vilaboa N
J Biomed Mater Res A; 2006 Jun; 77(3):608-17. PubMed ID: 16506177
[TBL] [Abstract][Full Text] [Related]
33. The effect of laser-treated titanium surface on human gingival fibroblast behavior.
Baltriukienė D; Sabaliauskas V; Balčiūnas E; Melninkaitis A; Liutkevičius E; Bukelskienė V; Rutkūnas V
J Biomed Mater Res A; 2014 Mar; 102(3):713-20. PubMed ID: 23554377
[TBL] [Abstract][Full Text] [Related]
34. Biological response of laser macrostructured and oxidized titanium alloy: an in vitro and in vivo study.
Paz MD; Álava JI; Goikoetxea L; Chiussi S; Díaz-Güemes I; Usón J; Sánchez F; León B
J Appl Biomater Biomech; 2011; 9(3):214-22. PubMed ID: 22190267
[TBL] [Abstract][Full Text] [Related]
35. Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry.
Tamayo JA; Riascos M; Vargas CA; Baena LM
Heliyon; 2021 May; 7(5):e06892. PubMed ID: 34027149
[TBL] [Abstract][Full Text] [Related]
36. Additive manufacturing of titanium alloys in the biomedical field: processes, properties and applications.
Trevisan F; Calignano F; Aversa A; Marchese G; Lombardi M; Biamino S; Ugues D; Manfredi D
J Appl Biomater Funct Mater; 2018 Apr; 16(2):57-67. PubMed ID: 28967051
[TBL] [Abstract][Full Text] [Related]
37. Plasma Electrolytic Oxidation of Titanium Implant Surfaces: Microgroove-Structures Improve Cellular Adhesion and Viability.
Hartjen P; Hoffmann A; Henningsen A; Barbeck M; Kopp A; Kluwe L; Precht C; Quatela O; Gaudin R; Heiland M; Friedrich RE; Knipfer C; Grubeanu D; Smeets R; Jung O
In Vivo; 2018; 32(2):241-247. PubMed ID: 29475905
[TBL] [Abstract][Full Text] [Related]
38. In vivo performance of selective electron beam-melted Ti-6Al-4V structures.
Ponader S; von Wilmowsky C; Widenmayer M; Lutz R; Heinl P; Körner C; Singer RF; Nkenke E; Neukam FW; Schlegel KA
J Biomed Mater Res A; 2010 Jan; 92(1):56-62. PubMed ID: 19165781
[TBL] [Abstract][Full Text] [Related]
39. Effect of Various Peening Methods on the Fatigue Properties of Titanium Alloy Ti6Al4V Manufactured by Direct Metal Laser Sintering and Electron Beam Melting.
Soyama H; Takeo F
Materials (Basel); 2020 May; 13(10):. PubMed ID: 32408590
[TBL] [Abstract][Full Text] [Related]
40. In vitro biocompatibility of an ultrafine grained zirconium.
Saldaña L; Méndez-Vilas A; Jiang L; Multigner M; González-Carrasco JL; Pérez-Prado MT; González-Martín ML; Munuera L; Vilaboa N
Biomaterials; 2007 Oct; 28(30):4343-54. PubMed ID: 17624424
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]