These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

315 related articles for article (PubMed ID: 25086117)

  • 21. Optimising the tip-apex-distance in trochanteric femoral fracture fixation using the ADAPT-navigated technique, a longitudinal matched cohort study.
    Herzog J; Wendlandt R; Hillbricht S; Burgkart R; Schulz AP
    Injury; 2019 Mar; 50(3):744-751. PubMed ID: 30782395
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Prospective randomized study comparing two cephalomedullary nails for elderly intertrochanteric fractures: Zimmer natural nail versus proximal femoral nail antirotation II.
    Shin YS; Chae JE; Kang TW; Han SB
    Injury; 2017 Jul; 48(7):1550-1557. PubMed ID: 28433451
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of lag screw placement for the dynamic hip screw and the cephalomedullary nail.
    Lindsey RW; Ahmed S; Overturf S; Tan A; Gugala Z
    Orthopedics; 2009 Jul; 32(7):488. PubMed ID: 19634855
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis.
    Kuzyk PR; Zdero R; Shah S; Olsen M; Waddell JP; Schemitsch EH
    J Orthop Trauma; 2012 Jul; 26(7):414-21. PubMed ID: 22337483
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A six-year retrospective analysis of cut-out risk predictors in cephalomedullary nailing for pertrochanteric fractures: Can the tip-apex distance (TAD) still be considered the best parameter?
    Caruso G; Bonomo M; Valpiani G; Salvatori G; Gildone A; Lorusso V; Massari L
    Bone Joint Res; 2017 Aug; 6(8):481-488. PubMed ID: 28790037
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails.
    Lee CH; Su KC; Chen KH; Pan CC; Wu YC
    J Int Med Res; 2018 Jun; 46(6):2128-2140. PubMed ID: 29848122
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effectiveness of fixation of hydroxyapatite-coated helical blade in preventing of the cut-out observed in treatment with proximal femoral nail of fractures of the femur intertrochanteric in elderly.
    Tosun HB; Uludağ A; Serbest S; Çiçek N; Demir S
    Ulus Travma Acil Cerrahi Derg; 2023 Mar; 29(3):379-388. PubMed ID: 36880615
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A novel angle on helical blade placement in trochanteric fractures - The axis-blade angle.
    Mao W; He YQ; Tang H; Chen XJ; Li LL; Dong YH
    Injury; 2019 Jul; 50(7):1333-1338. PubMed ID: 31130219
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Breakage of cephalomedullary nailing in operative treatment of trochanteric and subtrochanteric femoral fractures.
    von Rüden C; Hungerer S; Augat P; Trapp O; Bühren V; Hierholzer C
    Arch Orthop Trauma Surg; 2015 Feb; 135(2):179-185. PubMed ID: 25466724
    [TBL] [Abstract][Full Text] [Related]  

  • 30. No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis.
    Ng M; Shah NS; Golub I; Ciminero M; Zhai K; Kang KK; Emara AK; Piuzzi NS
    Eur J Orthop Surg Traumatol; 2022 Dec; 32(8):1617-1625. PubMed ID: 34665292
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures.
    Gazzotti G; Matino G; Tsatsis C; Sacchetti G; Baudi P; Catani F
    Acta Biomed; 2014 Aug; 85(2):135-43. PubMed ID: 25245649
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A dual telescoping lag screw nailing system for intertrochanteric fractures: retrospective analysis of clinical and radiologic outcomes.
    Innocenti M; Leggieri F; Secci G; Carulli C; Del Prete A; Civinini R
    Eur J Orthop Surg Traumatol; 2024 May; 34(4):2121-2128. PubMed ID: 38555541
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis.
    Li S; Chang SM; Niu WX; Ma H
    J Orthop Sci; 2015 Nov; 20(6):1062-9. PubMed ID: 26481124
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Comparison of the predictive value of tip-apex distance and calcar referenced tip-apex distance in treatment of femoral intertrochanteric fractures with Asian type proximal femoral nail fixation].
    Cai Y; Feng J; Chen Y; Shi M; Yu Z; Fang L; Zhou L; Xu S
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2020 Nov; 34(11):1359-1363. PubMed ID: 33191690
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Standardized Tip-Apex Distance (STAD): a modified individualized measurement of cephalic fixator position based on its own femoral head diameter in geriatric intertrochanteric fractures with internal fixation.
    Yang YF; Huang JW; Gao XS; Xu ZH
    BMC Musculoskelet Disord; 2023 Mar; 24(1):189. PubMed ID: 36915071
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Standard radiographic images in cephalomedullary nailing fixation for intertrochanteric femoral fractures].
    Chang S; Sun G; Wang Z; Zhang L; Tian K; Liu T; Wang X; Rui Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 Sep; 38(9):1130-1137. PubMed ID: 39300890
    [TBL] [Abstract][Full Text] [Related]  

  • 37. CalTAD is the Key Evaluation Tool for Measurement of Cephalic Fixation Position for Predicting Cut-Out in Geriatric Intertrochanteric Fracture Patients with Internal Fixations after Achieving Acceptable Reduction.
    Yang YF; Huang JW; Gao XS
    Geriatr Orthop Surg Rehabil; 2022; 13():21514593221083820. PubMed ID: 35386949
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Risk Factors Associated With Cephalomedullary Nail Cutout in the Treatment of Trochanteric Hip Fractures.
    Ciufo DJ; Zaruta DA; Lipof JS; Judd KT; Gorczyca JT; Ketz JP
    J Orthop Trauma; 2017 Nov; 31(11):583-588. PubMed ID: 28827502
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Rewriting the tip apex distance for the proximal femoral nail anti-rotation.
    Yam M; Chawla A; Kwek E
    Injury; 2017 Aug; 48(8):1843-1847. PubMed ID: 28689807
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical and radiological outcome of the Chimaera short nailing system in inter- and subtrochanteric fractures.
    Traverso A; Ngo TH; Fernandez Gil G; Lannes X; Steinmetz S; Moerenhout K
    Injury; 2023 Mar; 54(3):970-975. PubMed ID: 36646532
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.