311 related articles for article (PubMed ID: 25086524)
1. Utilization of optical tracking to validate a software-driven isocentric approach to robotic couch movements for proton radiotherapy.
Hsi WC; Law A; Schreuder AN; Zeidan OA
Med Phys; 2014 Aug; 41(8):081714. PubMed ID: 25086524
[TBL] [Abstract][Full Text] [Related]
2. Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system.
Wang N; Ghebremedhin A; Patyal B
Med Phys; 2015 Jun; 42(6):2979-91. PubMed ID: 26127051
[TBL] [Abstract][Full Text] [Related]
3. Utilization of optical tracking to assess efficacy of intracranial immobilization techniques in proton therapy.
Hsi WC; Schreuder AN; Zeidan O
J Appl Clin Med Phys; 2015 Sep; 16(5):205–218. PubMed ID: 26699301
[TBL] [Abstract][Full Text] [Related]
4. Validating robotic couch isocentricity with 3D surface imaging.
El-Sherif O; Remmes NB; Kruse JJ
J Appl Clin Med Phys; 2020 Aug; 21(8):168-172. PubMed ID: 32542911
[TBL] [Abstract][Full Text] [Related]
5. eNAL++: a new and effective off-line correction protocol for rotational setup errors when using a robotic couch.
Martens D; Luesink M; Huizenga H; Pasma KL
J Appl Clin Med Phys; 2015 Nov; 16(6):177-185. PubMed ID: 26699569
[TBL] [Abstract][Full Text] [Related]
6. SU-E-T-238: Annual QA of Proton Gantry with Robotic Table.
Wang N; Ghebremedhin A; Simpson R; Patyal B
Med Phys; 2012 Jun; 39(6Part13):3758. PubMed ID: 28517322
[TBL] [Abstract][Full Text] [Related]
7. Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy.
Bose S; Shukla H; Maltz J
Med Phys; 2010 May; 37(5):2004-16. PubMed ID: 20527534
[TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of a robotic 6-degree of freedom treatment couch for frameless radiosurgery.
Gevaert T; Verellen D; Engels B; Depuydt T; Heuninckx K; Tournel K; Duchateau M; Reynders T; De Ridder M
Int J Radiat Oncol Biol Phys; 2012 May; 83(1):467-74. PubMed ID: 21945110
[TBL] [Abstract][Full Text] [Related]
9. Beam's-eye-view imaging during non-coplanar lung SBRT.
Yip SS; Rottmann J; Berbeco RI
Med Phys; 2015 Dec; 42(12):6776-83. PubMed ID: 26632035
[TBL] [Abstract][Full Text] [Related]
10. Adaptive optimization by 6 DOF robotic couch in prostate volumetric IMRT treatment: rototranslational shift and dosimetric consequences.
Chiesa S; Placidi L; Azario L; Mattiucci GC; Greco F; Damiani A; Mantini G; Frascino V; Piermattei A; Valentini V; Balducci M
J Appl Clin Med Phys; 2015 Sep; 16(5):35-45. PubMed ID: 26699314
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric impacts of gantry angle misalignment on prostate cancer treatment using helical tomotherapy.
Su FC; Shi C; Crownover R; Swanson G; Papanikolaou N
Technol Cancer Res Treat; 2008 Aug; 7(4):287-93. PubMed ID: 18642967
[TBL] [Abstract][Full Text] [Related]
12. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system.
Takakura T; Mizowaki T; Nakata M; Yano S; Fujimoto T; Miyabe Y; Nakamura M; Hiraoka M
Phys Med Biol; 2010 Jan; 55(1):1-10. PubMed ID: 19949261
[TBL] [Abstract][Full Text] [Related]
13. A clinically feasible method for the detection of potential collision in proton therapy.
Zou W; Lin H; Plastaras JP; Wang H; Bui V; Vapiwala N; McDonough J; Tochner Z; Both S
Med Phys; 2012 Nov; 39(11):7094-101. PubMed ID: 23127100
[TBL] [Abstract][Full Text] [Related]
14. A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance.
Hua C; Yao W; Kidani T; Tomida K; Ozawa S; Nishimura T; Fujisawa T; Shinagawa R; Merchant TE
Br J Radiol; 2017 Nov; 90(1079):20170266. PubMed ID: 28830239
[TBL] [Abstract][Full Text] [Related]
15. Cone beam CT (CBCT) evaluation of inter- and intra-fraction motion for patients undergoing brain radiotherapy immobilized using a commercial thermoplastic mask on a robotic couch.
Lightstone AW; Tsao M; Baran PS; Chan G; Pang G; Ma L; Lochray F; Sahgal A
Technol Cancer Res Treat; 2012 Jun; 11(3):203-9. PubMed ID: 22376132
[TBL] [Abstract][Full Text] [Related]
16. Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery.
Shen J; Robertson DG; Bues M; Shipulin K; Liu W; Stoker J; Ashman JB; Lara P; Keole SR; Wong W; Vora SA
Med Phys; 2023 Jun; 50(6):3359-3367. PubMed ID: 36959772
[TBL] [Abstract][Full Text] [Related]
17. The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery.
Yu VY; Tran A; Nguyen D; Cao M; Ruan D; Low DA; Sheng K
Med Phys; 2015 Nov; 42(11):6457-67. PubMed ID: 26520735
[TBL] [Abstract][Full Text] [Related]
18. A novel verification method using a plastic scintillator imagining system for assessment of gantry sag in radiotherapy.
Tsuneda M; Nishio T; Saito A; Tanaka S; Suzuki T; Kawahara D; Matsushita K; Nishio A; Ozawa S; Karasawa K; Nagata Y
Med Phys; 2018 Jun; 45(6):2411-2424. PubMed ID: 29663431
[TBL] [Abstract][Full Text] [Related]
19. The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets-Quantification and possible corrections.
Wack LJ; Exner F; Wegener S; Sauer OA
J Appl Clin Med Phys; 2020 May; 21(5):56-64. PubMed ID: 32196950
[TBL] [Abstract][Full Text] [Related]
20. Characterization of a real-time surface image-guided stereotactic positioning system.
Peng JL; Kahler D; Li JG; Samant S; Yan G; Amdur R; Liu C
Med Phys; 2010 Oct; 37(10):5421-33. PubMed ID: 21089778
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]