189 related articles for article (PubMed ID: 25086541)
1. Model-based CT performance assessment and optimization for iodinated and noniodinated imaging tasks as a function of kVp and body size.
Samei E; Richard S; Lurwitz L
Med Phys; 2014 Aug; 41(8):081910. PubMed ID: 25086541
[TBL] [Abstract][Full Text] [Related]
2. Characteristic image quality of a third generation dual-source MDCT scanner: Noise, resolution, and detectability.
Solomon J; Wilson J; Samei E
Med Phys; 2015 Aug; 42(8):4941-53. PubMed ID: 26233220
[TBL] [Abstract][Full Text] [Related]
3. A comparative study based on image quality and clinical task performance for CT reconstruction algorithms in radiotherapy.
Li H; Dolly S; Chen HC; Anastasio MA; Low DA; Li HH; Michalski JM; Thorstad WL; Gay H; Mutic S
J Appl Clin Med Phys; 2016 Jul; 17(4):377-390. PubMed ID: 27455472
[TBL] [Abstract][Full Text] [Related]
4. Evaluating iterative reconstruction performance in computed tomography.
Chen B; Ramirez Giraldo JC; Solomon J; Samei E
Med Phys; 2014 Dec; 41(12):121913. PubMed ID: 25471973
[TBL] [Abstract][Full Text] [Related]
5. Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology.
Samei E; Richard S
Med Phys; 2015 Jan; 42(1):314-23. PubMed ID: 25563271
[TBL] [Abstract][Full Text] [Related]
6. Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers.
Tseng HW; Fan J; Kupinski MA; Sainath P; Hsieh J
Med Phys; 2014 Jul; 41(7):071910. PubMed ID: 24989388
[TBL] [Abstract][Full Text] [Related]
7. Dose optimization in pediatric cardiac x-ray imaging.
Gislason AJ; Davies AG; Cowen AR
Med Phys; 2010 Oct; 37(10):5258-69. PubMed ID: 21089760
[TBL] [Abstract][Full Text] [Related]
8. Dose optimization in cardiac x-ray imaging.
Gislason-Lee AJ; McMillan C; Cowen AR; Davies AG
Med Phys; 2013 Sep; 40(9):091911. PubMed ID: 24007162
[TBL] [Abstract][Full Text] [Related]
9. Iterative reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of diagnostic accuracy, image quality, and radiation dose in a phantom study.
Schindera ST; Diedrichsen L; Müller HC; Rusch O; Marin D; Schmidt B; Raupach R; Vock P; Szucs-Farkas Z
Radiology; 2011 Aug; 260(2):454-62. PubMed ID: 21493795
[TBL] [Abstract][Full Text] [Related]
10. Ultra-low peak voltage CT colonography: effect of iterative reconstruction algorithms on performance of radiologists who use anthropomorphic colonic phantoms.
Shin CI; Kim SH; Lee ES; Lee DH; Hwang EJ; Chung SY; Lee JM; Han JK; Choi BI
Radiology; 2014 Dec; 273(3):759-71. PubMed ID: 25010640
[TBL] [Abstract][Full Text] [Related]
11. Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods.
Chen B; Christianson O; Wilson JM; Samei E
Med Phys; 2014 Jul; 41(7):071909. PubMed ID: 24989387
[TBL] [Abstract][Full Text] [Related]
12. Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study.
Chen CM; Lin YY; Hsu MY; Hung CF; Liao YL; Tsai HY
Eur J Radiol; 2016 Sep; 85(9):1666-72. PubMed ID: 27501904
[TBL] [Abstract][Full Text] [Related]
13. 80-kVp CT using Iterative Reconstruction in Image Space algorithm for the detection of hypervascular hepatocellular carcinoma: phantom and initial clinical experience.
Hur S; Lee JM; Kim SJ; Park JH; Han JK; Choi BI
Korean J Radiol; 2012; 13(2):152-64. PubMed ID: 22438682
[TBL] [Abstract][Full Text] [Related]
14. Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study.
Husarik DB; Schindera ST; Morsbach F; Chuck N; Seifert B; Szucs-Farkas Z; Alkadhi H
Eur Radiol; 2014 Mar; 24(3):657-67. PubMed ID: 24154792
[TBL] [Abstract][Full Text] [Related]
15. Impact of iterative reconstructions on image noise and low-contrast object detection in low kVp simulated abdominal CT: a phantom study.
Holmquist F; Nyman U; Siemund R; Geijer M; Söderberg M
Acta Radiol; 2016 Sep; 57(9):1079-88. PubMed ID: 26663036
[TBL] [Abstract][Full Text] [Related]
16. Task-based assessment of neck CT protocols using patient-mimicking phantoms-effects of protocol parameters on dose and diagnostic performance.
Jahnke P; Conzelmann J; Genske U; Nunninger M; Scheel M; Hamm B; Diekhoff T
Eur Radiol; 2021 May; 31(5):3177-3186. PubMed ID: 33151393
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of Model-Based Iterative Reconstruction for CT Volumetry of Part-Solid Nodules and Solid Nodules in Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction at Various Dose Settings: An Anthropomorphic Chest Phantom Study.
Kim SK; Kim C; Lee KY; Cha J; Lim HJ; Kang EY; Oh YW
Korean J Radiol; 2019 Jul; 20(7):1195-1206. PubMed ID: 31270983
[TBL] [Abstract][Full Text] [Related]
18. Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology.
Price RG; Vance S; Cattaneo R; Schultz L; Elshaikh MA; Chetty IJ; Glide-Hurst CK
Med Phys; 2014 Aug; 41(8):081907. PubMed ID: 25086538
[TBL] [Abstract][Full Text] [Related]
19. Spatial resolution improvement and dose reduction potential for inner ear CT imaging using a z-axis deconvolution technique.
McCollough CH; Leng S; Sunnegardh J; Vrieze TJ; Yu L; Lane J; Raupach R; Stierstorfer K; Flohr T
Med Phys; 2013 Jun; 40(6):061904. PubMed ID: 23718595
[TBL] [Abstract][Full Text] [Related]
20. Size-specific optimization of CT protocols based on minimum detectability.
Zhang Y; Smitherman C; Samei E
Med Phys; 2017 Apr; 44(4):1301-1311. PubMed ID: 28122119
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]