242 related articles for article (PubMed ID: 25091535)
1. Reconstruction after retrosigmoid approaches using autologous fat graft-assisted Medpor Titan cranioplasty: assessment of postoperative cerebrospinal fluid leaks and headaches in 60 cases.
Ling PY; Mendelson ZS; Reddy RK; Jyung RW; Liu JK
Acta Neurochir (Wien); 2014 Oct; 156(10):1879-88. PubMed ID: 25091535
[TBL] [Abstract][Full Text] [Related]
2. Cranioplasty Using Polymethylmethacrylate Cement Following Retrosigmoid Craniectomy Decreases the Rate of Cerebrospinal Fluid Leak and Pseudomeningocele.
Ou C; Chen Y; Mo J; Wang S; Gai S; Xing R; Wang B; Wu C
J Craniofac Surg; 2019; 30(2):566-570. PubMed ID: 31137454
[TBL] [Abstract][Full Text] [Related]
3. Prevention of postoperative cerebrospinal fluid leaks with multilayered reconstruction using titanium mesh-hydroxyapatite cement cranioplasty after translabyrinthine resection of acoustic neuroma.
Manjila S; Weidenbecher M; Semaan MT; Megerian CA; Bambakidis NC
J Neurosurg; 2013 Jul; 119(1):113-20. PubMed ID: 23350781
[TBL] [Abstract][Full Text] [Related]
4. Fat graft-assisted internal auditory canal closure after retrosigmoid transmeatal resection of acoustic neuroma: Technique for prevention of cerebrospinal fluid leakage.
Azad T; Mendelson ZS; Wong A; Jyung RW; Liu JK
J Clin Neurosci; 2016 Feb; 24():124-7. PubMed ID: 26482457
[TBL] [Abstract][Full Text] [Related]
5. Cisterna magna arachnoid membrane suturing decreases incidence of pseudomeningocele formation and incisional CSF leakage.
Pitskhelauri D; Kudieva E; Moshchev D; Ananev E; Shifrin M; Danilov G; Melnikova-Pitskhelauri T; Kachkov I; Bykanov A; Sanikidze A
Acta Neurochir (Wien); 2018 May; 160(5):1079-1087. PubMed ID: 29557532
[TBL] [Abstract][Full Text] [Related]
6. Cost Analysis of Cerebrospinal Fluid Leaks and Cerebrospinal Fluid Leak Prevention in Patients Undergoing Cerebellopontine Angle Surgery.
Chern A; Hunter JB; Bennett ML
Otol Neurotol; 2017 Jan; 38(1):147-151. PubMed ID: 27779560
[TBL] [Abstract][Full Text] [Related]
7. Keyhole retrosigmoid approach without watertight dural closure - Evaluation of a minimalistic approach.
Wong AK; Wong RH
Clin Neurol Neurosurg; 2023 Apr; 227():107625. PubMed ID: 36870088
[TBL] [Abstract][Full Text] [Related]
8. Reduced CSF leak in complete calvarial reconstructions of microvascular decompression craniectomies using calcium phosphate cement.
Eseonu CI; Goodwin CR; Zhou X; Theodros D; Bender MT; Mathios D; Bettegowda C; Lim M
J Neurosurg; 2015 Dec; 123(6):1476-9. PubMed ID: 26230465
[TBL] [Abstract][Full Text] [Related]
9. Prevention of Postoperative Cerebrospinal Fluid Leaks After Translabyrinthine Tumor Resection With Resorbable Mesh Cranioplasty.
Hunter JB; Sweeney AD; Carlson ML; Wanna GB; Rivas A; Weaver KD; Chambless LB; Thompson RS; Haynes DS; Bennett ML
Otol Neurotol; 2015 Sep; 36(9):1537-42. PubMed ID: 26208128
[TBL] [Abstract][Full Text] [Related]
10. Hydroxyapatite cement cranioplasty following translabyrinthine approach: Long-term study of 369 cases.
Volsky PG; Hillman TA; Stromberg KJ; Buchinsky FJ; Chen DA; Jackson NM; Arriaga MA
Laryngoscope; 2017 Sep; 127(9):2120-2125. PubMed ID: 28059442
[TBL] [Abstract][Full Text] [Related]
11. Prevention and management of cerebrospinal fluid leak following vestibular schwannoma surgery.
Fishman AJ; Marrinan MS; Golfinos JG; Cohen NL; Roland JT
Laryngoscope; 2004 Mar; 114(3):501-5. PubMed ID: 15091225
[TBL] [Abstract][Full Text] [Related]
12. Primary Dural Closure for Retrosigmoid Approaches.
Venable GT; Roberts ML; Lee RP; Michael LM
J Neurol Surg B Skull Base; 2018 Aug; 79(4):330-334. PubMed ID: 30009112
[No Abstract] [Full Text] [Related]
13. Resorbable Mesh Cranioplasty Repair of Bilateral Cerebrospinal Fluid Leaks Following Pediatric Simultaneous Bilateral Auditory Brainstem Implant Surgery.
Colletti G; Mandalà M; Colletti V; Deganello A; Allevi F; Colletti L
Otol Neurotol; 2017 Apr; 38(4):606-609. PubMed ID: 28121970
[TBL] [Abstract][Full Text] [Related]
14. Duraplasty using autologous fascia lata reenforced by on-site pedicled muscle flap: technical note.
Abuzayed B; Kafadar AM; Oğuzoğlu SA; Canbaz B; Kaynar MY
J Craniofac Surg; 2009 Mar; 20(2):435-8. PubMed ID: 19326487
[TBL] [Abstract][Full Text] [Related]
15. Ten-Year Experience of Dural Reconstruction Using a Collagen Matrix Inlay Graft in Posterior Fossa Surgery: A Propensity Score-Matched Study.
Kim KH; Park B; Byoun HS; Lim J; Kwon HJ; Choi SW; Koh HS; Youm JY; Kim SH
World Neurosurg; 2020 Sep; 141():e383-e388. PubMed ID: 32454202
[TBL] [Abstract][Full Text] [Related]
16. Dural Reconstruction With Autologous Rectus Fascia: A New Technique for Addressing Large-Sized Defects During Cranioplasty.
Santiago G; Wolff A; Huang J; Weingart J; Brem H; Gordon CR
J Craniofac Surg; 2019; 30(2):326-329. PubMed ID: 30439737
[TBL] [Abstract][Full Text] [Related]
17. Calcium Phosphate Cement Cranioplasty Decreases the Rate of Cerebrospinal Fluid Leak and Wound Infection Compared with Titanium Mesh Cranioplasty: Retrospective Study of 672 Patients.
Foster KA; Shin SS; Prabhu B; Fredrickson A; Sekula RF
World Neurosurg; 2016 Nov; 95():414-418. PubMed ID: 26921704
[TBL] [Abstract][Full Text] [Related]
18. Factors Predicting Cerebrospinal Fluid Leaks in Microvascular Decompressions: A Case Series of 1011 Patients.
Xu R; So RJ; Materi J; Nair SK; Alomari SO; Huang J; Lim M; Bettegowda C
Oper Neurosurg (Hagerstown); 2023 Mar; 24(3):262-267. PubMed ID: 36656065
[TBL] [Abstract][Full Text] [Related]
19. Use of Autologous Fat Grafts for the Endoscopic Reconstruction of Skull Base Defects: Indications, Outcomes, and Complications.
Lam K; Luong AU; Yao WC; Citardi MJ
Am J Rhinol Allergy; 2018 Jul; 32(4):310-317. PubMed ID: 29732935
[TBL] [Abstract][Full Text] [Related]
20. Polyethylene glycol hydrogel dural sealant may reduce incisional cerebrospinal fluid leak after posterior fossa surgery.
Than KD; Baird CJ; Olivi A
Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONS182-6; discussion ONS186-7. PubMed ID: 18728598
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]