BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

616 related articles for article (PubMed ID: 25092422)

  • 1. Photoplethysmograph signal reconstruction based on a novel hybrid motion artifact detection-reduction approach. Part I: Motion and noise artifact detection.
    Chong JW; Dao DK; Salehizadeh SM; McManus DD; Darling CE; Chon KH; Mendelson Y
    Ann Biomed Eng; 2014 Nov; 42(11):2238-50. PubMed ID: 25092422
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Photoplethysmograph signal reconstruction based on a novel motion artifact detection-reduction approach. Part II: Motion and noise artifact removal.
    Salehizadeh SM; Dao DK; Chong JW; McManus D; Darling C; Mendelson Y; Chon KH
    Ann Biomed Eng; 2014 Nov; 42(11):2251-63. PubMed ID: 24823655
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.
    Dao D; Salehizadeh SMA; Noh Y; Chong JW; Cho CH; McManus D; Darling CE; Mendelson Y; Chon KH
    IEEE J Biomed Health Inform; 2017 Sep; 21(5):1242-1253. PubMed ID: 28113791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Signal quality measures for pulse oximetry through waveform morphology analysis.
    Sukor JA; Redmond SJ; Lovell NH
    Physiol Meas; 2011 Mar; 32(3):369-84. PubMed ID: 21330696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram.
    Selvaraj N; Mendelson Y; Shelley KH; Silverman DG; Chon KH
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():4972-5. PubMed ID: 22255454
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Novel Personalized Motion and Noise Artifact (MNA) Detection Method for Smartphone Photoplethysmograph (PPG) Signals.
    Tabei F; Kumar R; Phan TN; McManus DD; Chong JW
    IEEE Access; 2018; 6():60498-60512. PubMed ID: 31263653
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data.
    Krishnan R; Natarajan BB; Warren S
    IEEE Trans Biomed Eng; 2010 Aug; 57(8):1867-76. PubMed ID: 20172800
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor.
    Salehizadeh SM; Dao D; Bolkhovsky J; Cho C; Mendelson Y; Chon KH
    Sensors (Basel); 2015 Dec; 16(1):. PubMed ID: 26703618
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reference signal less Fourier analysis based motion artifact removal algorithm for wearable photoplethysmography devices to estimate heart rate during physical exercises.
    Pankaj ; Kumar A; Komaragiri R; Kumar M
    Comput Biol Med; 2022 Feb; 141():105081. PubMed ID: 34952340
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis.
    Couceiro R; Carvalho P; Paiva RP; Henriques J; Muehlsteff J
    Physiol Meas; 2014 Dec; 35(12):2369-88. PubMed ID: 25390186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Motion Artifact Removal of Photoplethysmogram (PPG) Signal.
    Majeed IA; Jos S; Arora R; Choi K; Bae S
    Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():5576-5580. PubMed ID: 31947119
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph.
    Warren KM; Harvey JR; Chon KH; Mendelson Y
    Sensors (Basel); 2016 Mar; 16(3):. PubMed ID: 26959034
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Photoplethysmographic Signal Isolated From an Additive Motion Artifact by Frequency Translation.
    Sinchai S; Kainan P; Wardkein P; Koseeyaporn J
    IEEE Trans Biomed Circuits Syst; 2018 Aug; 12(4):904-917. PubMed ID: 29994775
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.
    Peng F; Liu H; Wang W
    Physiol Meas; 2015 Oct; 36(10):2159-70. PubMed ID: 26334000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel diversity method for smartphone camera-based heart rhythm signals in the presence of motion and noise artifacts.
    Tabei F; Zaman R; Foysal KH; Kumar R; Kim Y; Chong JW
    PLoS One; 2019; 14(6):e0218248. PubMed ID: 31216314
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Study on resistance to motion artifact in pulse oximetry measurement using segment filter method].
    Li QB; Nie X; Zhang GJ; Wu JG
    Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Nov; 29(11):2994-7. PubMed ID: 20101971
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A wrist worn SpO2 monitor with custom finger probe for motion artifact removal.
    Preejith SP; Ravindran AS; Hajare R; Joseph J; Sivaprakasam M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():5777-5780. PubMed ID: 28269567
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering.
    Wang M; Li Z; Zhang Q; Wang G
    Sensors (Basel); 2019 Jul; 19(15):. PubMed ID: 31357674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A motion-tolerant approach for monitoring SpO
    Fan F; Yan Y; Tang Y; Zhang H
    Comput Biol Med; 2017 Dec; 91():291-305. PubMed ID: 29102826
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts.
    Ye Y; He W; Cheng Y; Huang W; Zhang Z
    Sensors (Basel); 2017 Feb; 17(2):. PubMed ID: 28212327
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.