These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 25096329)

  • 1. Low cost referenced luminescent imaging of oxygen and pH with a 2-CCD colour near infrared camera.
    Ehgartner J; Wiltsche H; Borisov SM; Mayr T
    Analyst; 2014 Oct; 139(19):4924-33. PubMed ID: 25096329
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microfluidic oxygen imaging using integrated optical sensor layers and a color camera.
    Ungerböck B; Charwat V; Ertl P; Mayr T
    Lab Chip; 2013 Apr; 13(8):1593-601. PubMed ID: 23443957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Background-free referenced luminescence sensing and imaging of pH using upconverting phosphors and color camera read-out.
    Meier RJ; Simbürger JM; Soukka T; Schäferling M
    Anal Chem; 2014 Jun; 86(11):5535-40. PubMed ID: 24798791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Trace Ammonia Sensors Based on Fluorescent Near-Infrared-Emitting aza-BODIPY Dyes.
    Strobl M; Walcher A; Mayr T; Klimant I; Borisov SM
    Anal Chem; 2017 Mar; 89(5):2859-2865. PubMed ID: 28264569
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Time-resolved pH/pO2 mapping with luminescent hybrid sensors.
    Schröder CR; Polerecky L; Klimant I
    Anal Chem; 2007 Jan; 79(1):60-70. PubMed ID: 17194122
    [TBL] [Abstract][Full Text] [Related]  

  • 6. NIR-emitting aza-BODIPY dyes--new building blocks for broad-range optical pH sensors.
    Strobl M; Rappitsch T; Borisov SM; Mayr T; Klimant I
    Analyst; 2015 Nov; 140(21):7150-3. PubMed ID: 26402484
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous Determination of Oxygen and pH Inside Microfluidic Devices Using Core-Shell Nanosensors.
    Ehgartner J; Strobl M; Bolivar JM; Rabl D; Rothbauer M; Ertl P; Borisov SM; Mayr T
    Anal Chem; 2016 Oct; 88(19):9796-9804. PubMed ID: 27610829
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ratiometric fluorescent sensor with large pseudo-Stokes shifts for precise sensing and imaging of pH without interferential background fluorescence.
    Wang T; Liao C; Jiang Z; Wang J; Ma Y; Lin H; Zhang Y; Lv H; Zhang X; Hu Y; Yang Y; Zhou G
    Talanta; 2024 Jan; 266(Pt 1):125041. PubMed ID: 37556950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hyperspectral Luminescence Imaging in Combination with Signal Deconvolution Enables Reliable Multi-Indicator-Based Chemical Sensing.
    Zieger SE; Mosshammer M; Kühl M; Koren K
    ACS Sens; 2021 Jan; 6(1):183-191. PubMed ID: 33337140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and Fabrication of a Ratiometric Planar Optode for Simultaneous Imaging of pH and Oxygen.
    Jiang Z; Yu X; Hao Y
    Sensors (Basel); 2017 Jun; 17(6):. PubMed ID: 28590430
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A sprayable luminescent pH sensor and its use for wound imaging in vivo.
    Schreml S; Meier RJ; Weiß KT; Cattani J; Flittner D; Gehmert S; Wolfbeis OS; Landthaler M; Babilas P
    Exp Dermatol; 2012 Dec; 21(12):951-3. PubMed ID: 23171458
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multi-ion detection by one-shot optical sensors using a colour digital photographic camera.
    Lapresta-Fernández A; Capitán-Vallvey LF
    Analyst; 2011 Oct; 136(19):3917-26. PubMed ID: 21818486
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Referenced dual pressure- and temperature-sensitive paint for digital color camera read out.
    Fischer LH; Karakus C; Meier RJ; Risch N; Wolfbeis OS; Holder E; Schäferling M
    Chemistry; 2012 Dec; 18(49):15706-13. PubMed ID: 23070744
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dual fluorescence sensor for trace oxygen and temperature with unmatched range and sensitivity.
    Baleizão C; Nagl S; Schäferling M; Berberan-Santos MN; Wolfbeis OS
    Anal Chem; 2008 Aug; 80(16):6449-57. PubMed ID: 18651755
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Open air calibration with temperature compensation of a luminescence quenching-based oxygen sensor for portable instrumentation.
    Palma AJ; López-González J; Asensio LJ; Fernández-Ramos MD; Capitán-Vallvey LF
    Anal Chem; 2007 Apr; 79(8):3173-9. PubMed ID: 17367116
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrabright Red-Emitting Photostable Perylene Bisimide Dyes: New Indicators for Ratiometric Sensing of High pH or Carbon Dioxide.
    Pfeifer D; Klimant I; Borisov SM
    Chemistry; 2018 Jul; 24(42):10711-10720. PubMed ID: 29738607
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Full-range optical pH sensor based on imaging techniques.
    Capel-Cuevas S; Cuéllar MP; de Orbe-Payá I; Pegalajar MC; Capitán-Vallvey LF
    Anal Chim Acta; 2010 Nov; 681(1-2):71-81. PubMed ID: 21035605
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optical Chemical Sensor Using Intensity Ratiometric Fluorescence Signals for Fast and Reliable pH Determination.
    Frankær CG; Hussain KJ; Dörge TC; Sørensen TJ
    ACS Sens; 2019 Jan; 4(1):26-31. PubMed ID: 30592615
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New highly fluorescent pH indicator for ratiometric RGB imaging of pCO
    Schutting S; Klimant I; de Beer D; Borisov SM
    Methods Appl Fluoresc; 2014 Apr; 2(2):024001. PubMed ID: 29148465
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Oxygen Sensing Difluoroboron β-Diketonate Polylactide Materials with Tunable Dynamic Ranges for Wound Imaging.
    DeRosa CA; Seaman SA; Mathew AS; Gorick CM; Fan Z; Demas JN; Peirce SM; Fraser CL
    ACS Sens; 2016 Nov; 1(11):1366-1373. PubMed ID: 28042606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.