These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
299 related articles for article (PubMed ID: 25099476)
21. Comparison of neointimal coverage between everolimus-eluting stents and sirolimus-eluting stents: an optical coherence tomography substudy of the RESET (Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial). Kubo T; Akasaka T; Kozuma K; Kimura K; Kawamura M; Sumiyoshi T; Ino Y; Morino Y; Tanabe K; Kadota K; Kimura T; EuroIntervention; 2015 Sep; 11(5):564-71. PubMed ID: 26390517 [TBL] [Abstract][Full Text] [Related]
22. Comparative Effectiveness and Safety of Polymer-Free Biolimus-Eluting Stent and Durable Polymer Everolimus-Eluting Stent in All-Comer Patients Who Underwent Percutaneous Coronary Interventions. Pepe M; Biondi-Zoccai G; Corcione N; Nestola PL; Ferraro P; Morello A; Conte S; Prati F; Bianchi FP; Bortone AS; Giordano A Am J Cardiol; 2019 Jul; 124(2):195-204. PubMed ID: 31103132 [TBL] [Abstract][Full Text] [Related]
23. Comparison of biolimus A9-eluting (Nobori) and everolimus-eluting (Promus Element) stents in patients with de novo native long coronary artery lesions: a randomized Long Drug-Eluting Stent V trial. Lee JY; Park DW; Kim YH; Ahn JM; Kim WJ; Kang SJ; Lee SW; Lee CW; Park SW; Yun SC; Yang TH; Lee BK; Lee NH; Yang JY; Shin WY; Park HS; Kim KS; Hur SH; Lee SY; Park JS; Choi YS; Lee SU; Her SH; Park SJ Circ Cardiovasc Interv; 2014 Jun; 7(3):322-9. PubMed ID: 24823426 [TBL] [Abstract][Full Text] [Related]
24. Abluminal biodegradable polymer biolimus-eluting versus durable polymer everolimus-eluting stent in patients with diabetes mellitus: 5 years follow-up from the COMPARE II trial. Paradies V; Vlachojannis GJ; Royaards KJ; Wassing J; van der Ent M; Smits PC Int J Cardiol; 2019 Sep; 290():40-44. PubMed ID: 31101545 [TBL] [Abstract][Full Text] [Related]
25. Comparison of zotarolimus-eluting stent and everolimus-eluting stent for vascular healing response: serial 3-month and 12-month optical coherence tomography study. Kim SJ; Lee H; Cho JM; Park CB; Kim W; Kato K; Yonetsu T; Kim CJ; Jang IK Coron Artery Dis; 2013 Aug; 24(5):431-9. PubMed ID: 23722649 [TBL] [Abstract][Full Text] [Related]
26. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography. Ohtani H; Kimura S; Sugiyama T; Hishikari K; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hikita H; Ashikaga T; Takahashi A; Isobe M Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750 [TBL] [Abstract][Full Text] [Related]
27. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging. Kobayashi N; Ito Y; Yamawaki M; Araki M; Sakai T; Sakamoto Y; Mori S; Tsutsumi M; Nauchi M; Honda Y; Tokuda T; Makino K; Shirai S; Hirano K Int J Cardiovasc Imaging; 2018 Apr; 34(4):515-522. PubMed ID: 29159531 [TBL] [Abstract][Full Text] [Related]
28. Optical coherence tomography evaluation of late strut coverage patterns between first-generation drug-eluting stents and everolimus-eluting stent. Toledano Delgado FJ; Alvarez-Ossorio MP; de Lezo Cruz-Conde JS; Bellido FM; Romero Moreno MÁ; Fernández-Aceytuno AM; de Lezo Herrerosde Tejada JS; Pineda SO; Saint-Gerons JM; Pavlovic D Catheter Cardiovasc Interv; 2014 Nov; 84(5):720-6. PubMed ID: 24174291 [TBL] [Abstract][Full Text] [Related]
29. Impact of different stent alloys on human vascular response to everolimus-eluting stent: an optical coherence tomography study: the OCTEVEREST. Guagliumi G; Capodanno D; Ikejima H; Bezerra HG; Sirbu V; Musumeci G; Fiocca L; Lortkipanidze N; Vassileva A; Tahara S; Valsecchi O; Costa MA Catheter Cardiovasc Interv; 2013 Feb; 81(3):510-8. PubMed ID: 22431208 [TBL] [Abstract][Full Text] [Related]
30. Comparison of MECHANISM of early and late vascular responses following treatment of ST-elevation acute myocardial infarction with two different everolimus-eluting stents: a randomized controlled trial of biodegradable versus durable polymer stents. Otake H; Ishida M; Nakano S; Higuchi Y; Hibi K; Kuriyama N; Iwasaki M; Kataoka T; Kubo T; Tsujita K; Ashikaga T; Shinke T; Itoh T; Kimura T; Morino Y; Cardiovasc Interv Ther; 2023 Jan; 38(1):75-85. PubMed ID: 35896895 [TBL] [Abstract][Full Text] [Related]
31. Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent. Ogura K; Tsujita H; Oishi Y; Matsumoto H; Matsukawa N; Sakai R; Arai T; Sato S; Tanaka H; Masaki R; Arai K; Nomura K; Kosaki R; Sakai K; Sekimoto T; Kondo S; Tsukamoto S; Mori H; Yamamoto MH; Wakabayashi K; Suzuki H; Ochiai M; Shinke T Int Heart J; 2021 May; 62(3):510-519. PubMed ID: 33994509 [TBL] [Abstract][Full Text] [Related]
32. Comparable vascular response of a new generation sirolimus eluting stents when compared to fluoropolymer everolimus eluting stents in the porcine coronary restenosis model. Buszman PP; Michalak MJ; Pruski M; Fernandez C; Jelonek M; Janas A; Savard C; Gwiazdowska-Nowotka B; Żurakowski A; Wojakowski W; Buszman PE; Milewski K Cardiol J; 2016; 23(6):657-666. PubMed ID: 27976797 [TBL] [Abstract][Full Text] [Related]
33. Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in patients with acute myocardial infarction. Lee HJ; Park TK; Song YB; Choi YJ; Yu CW; Yang JH; Hahn JY; Choi SH; Choi RK; Choi JH; Park JS; Kim JS; Kim TH; Jang HJ; Lee SH; Shim WH; Roh YM; Gwon HC Int J Cardiol; 2015 Mar; 183():190-7. PubMed ID: 25668147 [TBL] [Abstract][Full Text] [Related]
34. Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis. Matsuhiro Y; Nakamura D; Shutta R; Kawamura A; Nakamura H; Okamoto N; Matsunaga-Lee Y; Yano M; Egami Y; Sakata Y; Nishino M; Tanouchi J Int J Cardiovasc Imaging; 2021 Apr; 37(4):1131-1141. PubMed ID: 33165669 [TBL] [Abstract][Full Text] [Related]
35. Comparison of abluminal biodegradable polymer biolimus-eluting stents and durable polymer everolimus-eluting stents in the treatment of coronary bifurcations. Costopoulos C; Latib A; Naganuma T; Sticchi A; Ferrarello S; Regazzoli D; Chieffo A; Figini F; Carlino M; Montorfano M; Naim C; Kawaguchi M; Gerasimou A; Giannini F; Godino C; Colombo A Catheter Cardiovasc Interv; 2014 May; 83(6):889-95. PubMed ID: 23804318 [TBL] [Abstract][Full Text] [Related]
36. Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. Puricel S; Arroyo D; Corpataux N; Baeriswyl G; Lehmann S; Kallinikou Z; Muller O; Allard L; Stauffer JC; Togni M; Goy JJ; Cook S J Am Coll Cardiol; 2015 Mar; 65(8):791-801. PubMed ID: 25720622 [TBL] [Abstract][Full Text] [Related]
37. Six-month follow-up evaluation for everolimus-eluting stents by intracoronary optical coherence tomography: comparison with paclitaxel-eluting stents. Takano M; Murakami D; Yamamoto M; Kurihara O; Murai K; Inami T; Kimata N; Ohba T; Seino Y; Mizuno K Int J Cardiol; 2013 Jun; 166(1):181-6. PubMed ID: 22075410 [TBL] [Abstract][Full Text] [Related]
38. An optical coherence tomography study of two new generation stents with biodegradable polymer carrier, eluting paclitaxel vs. biolimus-A9. Davlouros PA; Mavronasiou E; Xanthopoulou I; Karantalis V; Tsigkas G; Hahalis G; Alexopoulos D Int J Cardiol; 2012 Jun; 157(3):341-6. PubMed ID: 21220173 [TBL] [Abstract][Full Text] [Related]
39. Early vascular healing after implantation of the polymer-free biolimus-eluting stent or the ultrathin strut biodegradable polymer sirolimus-eluting stent in patients with ST-segment elevation myocardial infarction. Hansen KN; Maeng M; Antonsen L; Maehara A; Jakobsen L; Ellert J; Terkelsen CJ; Ahlehoff O; Thim T; Fallesen CO; Noori M; Veien KT; Jensen LO; Christiansen EH Coron Artery Dis; 2022 May; 33(3):196-205. PubMed ID: 34985003 [TBL] [Abstract][Full Text] [Related]
40. Safety and efficacy profile of bioresorbable-polylactide-polymer-biolimus-A9-eluting stents versus durable-polymer-everolimus- and zotarolimus-eluting stents in patients with acute coronary syndrome. Jaguszewski M; Dörig M; Frangieh AH; Ghadri JR; Cammann VL; Diekmann J; Napp LC; D'Ascenzo F; Imori Y; Obeid S; Maier W; Lüscher TF; Templin C Catheter Cardiovasc Interv; 2016 Nov; 88(6):E173-E182. PubMed ID: 27377554 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]