These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 25106015)

  • 1. Dental gypsum verification jig to verify implant positions: a clinical report.
    Alhashim A; Flinton RJ
    J Oral Implantol; 2014 Aug; 40(4):495-9. PubMed ID: 25106015
    [No Abstract]   [Full Text] [Related]  

  • 2. Use of digital data acquisition and CAD/CAM technology for the fabrication of a fixed complete dental prosthesis on dental implants.
    Lin WS; Harris BT; Zandinejad A; Morton D
    J Prosthet Dent; 2014 Jan; 111(1):1-5. PubMed ID: 24189115
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Full-arch metal-resin cement- and screw-retained provisional restoration for immediately loaded implants.
    Baig MR; Rajan G
    J Oral Implantol; 2010; 36(3):219-23. PubMed ID: 20553176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of three-implant-supported fixed dentures and two-implant-retained overdentures in the edentulous mandible: a pilot study of treatment efficacy and patient satisfaction.
    De Kok IJ; Chang KH; Lu TS; Cooper LF
    Int J Oral Maxillofac Implants; 2011; 26(2):415-26. PubMed ID: 21483895
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A three-appointment alternative treatment protocol for fabricating an implant-supported milled bar overdenture.
    Lin WS; Ozdemir E; Morton D
    J Prosthet Dent; 2012 Feb; 107(2):75-9. PubMed ID: 22304740
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The 2-visit CAD-CAM implant-retained overdenture: a clinical report.
    Bidra AS
    J Oral Implantol; 2014 Dec; 40(6):722-8. PubMed ID: 23574574
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A modified method of immediate occlusal loading using a reinforced framework denture: a case report.
    Mazaro JV; Vedovatto E; Gennari Filho H; Pellizzer EP
    Dent Today; 2009 Mar; 28(3):78, 80, 82. PubMed ID: 19323320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.
    Acocella A; Ercoli C; Geminiani A; Feng C; Billi M; Acocella G; Giannini D; Sacco R
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e98-108. PubMed ID: 22013945
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.
    Ercoli C; Geminiani A; Feng C; Lee H
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e188-95. PubMed ID: 22176765
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evidence-based treatment for the edentulous patient.
    Williamson RA
    Dent Today; 2010 Oct; 29(10):140, 142-5. PubMed ID: 21086803
    [No Abstract]   [Full Text] [Related]  

  • 11. Treating the edentulous mandible: immediately loaded implants.
    Nishioka RS; Garcia-Júnior IR; Souza FA; Luvizuto ER
    Dent Today; 2008 Dec; 27(12):70, 72-3. PubMed ID: 19133635
    [No Abstract]   [Full Text] [Related]  

  • 12. Application of interim fixed reference points to maintain the occlusal vertical dimension: a technique for immediate loading protocols in the edentulous mandible.
    Holst S; Blatz MB; Bergler M; Wichmann M
    J Prosthet Dent; 2006 Aug; 96(2):134-8. PubMed ID: 16911891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simple method of record base fabrication for a bar-retained implant overdenture.
    Oh WS; Park JM
    J Prosthodont; 2012 Dec; 21(8):638-40. PubMed ID: 22762518
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An implant-supported, cobalt-chromium milled bar and nonflanged attachment-retained overdenture to rehabilitate the edentulous mandible.
    Lowe LG; Shcherbukhin VM
    J Prosthet Dent; 2009 Jul; 102(1):46-51. PubMed ID: 19573689
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Digitally planned and fabricated mandibular fixed complete dentures. Part 2. Prosthodontic phase.
    Kattadiyil MT; Goodacre CJ; Lozada JL; Garbacea A
    Int J Prosthodont; 2015; 28(2):119-23. PubMed ID: 25822295
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Case Report--Fabrication Of Hinged Sectional Dentures In Restricted Mouth Opening Patients.
    Mikkilineni H; Reddy DM
    J N J Dent Assoc; 2015; 86(1):24-6. PubMed ID: 26215029
    [No Abstract]   [Full Text] [Related]  

  • 17. A comparison of fit of CNC-milled titanium and zirconia frameworks to implants.
    Abduo J; Lyons K; Waddell N; Bennani V; Swain M
    Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e20-9. PubMed ID: 21414138
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fabrication of the mandibular implant-supported fixed restoration using CAD/CAM technology: a clinical report.
    Reshad M; Cascione D; Aalam AA
    J Prosthet Dent; 2009 Nov; 102(5):271-8. PubMed ID: 19853167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant stability measurements of two immediate loading protocols for the edentulous mandible: rigid and semi-rigid splinting of the implants.
    Lee HJ; Aparecida de Mattias Sartori I; Alcântara PR; Vieira RA; Suzuki D; Gasparini Kiatake Fontão F; Tiossi R
    Implant Dent; 2012 Dec; 21(6):486-90. PubMed ID: 23114828
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The transmandibular implant: prosthodontic treatment considerations.
    Unger JW; Crabtree DG
    J Prosthet Dent; 1991 Nov; 66(5):660-4. PubMed ID: 1805005
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.