These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

369 related articles for article (PubMed ID: 25106111)

  • 1. Quantitative analysis of temperature dependent acoustic trapping characteristics by using concentric annular type dual element ultrasonic transducer.
    Chung IY; Lee J
    Ultrasonics; 2015 Feb; 56():220-6. PubMed ID: 25106111
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical analysis for transverse microbead trapping using 30 MHz focused ultrasound in ray acoustics regime.
    Lee J
    Ultrasonics; 2014 Jan; 54(1):11-9. PubMed ID: 23809757
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Potential-well model in acoustic tweezers.
    Kang ST; Yeh CK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Jun; 57(6):1451-9. PubMed ID: 20529720
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microfluidic acoustic trapping force and stiffness measurement using viscous drag effect.
    Lee J; Jeong JS; Shung KK
    Ultrasonics; 2013 Jan; 53(1):249-54. PubMed ID: 22824623
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Backscattering measurement from a single microdroplet.
    Lee J; Chang JH; Jeong JS; Lee C; Teh SY; Lee A; Shung KK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Apr; 58(4):874-9. PubMed ID: 21507767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Temperature and trapping characterization of an acoustic trap with miniaturized integrated transducers--towards in-trap temperature regulation.
    Johansson L; Evander M; Lilliehorn T; Almqvist M; Nilsson J; Laurell T; Johansson S
    Ultrasonics; 2013 Jul; 53(5):1020-32. PubMed ID: 23497805
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The acoustic properties, centered on 20 MHZ, of an IEC agar-based tissue-mimicking material and its temperature, frequency and age dependence.
    Brewin MP; Pike LC; Rowland DE; Birch MJ
    Ultrasound Med Biol; 2008 Aug; 34(8):1292-306. PubMed ID: 18343021
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of the sound velocity in fluids using the echo signals from scattering particles.
    Lenz M; Bock M; Kühnicke E; Pal J; Cramer A
    Ultrasonics; 2012 Jan; 52(1):117-24. PubMed ID: 21824636
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Frequency tracking in acoustic trapping for improved performance stability and system surveillance.
    Hammarström B; Evander M; Wahlström J; Nilsson J
    Lab Chip; 2014 Mar; 14(5):1005-13. PubMed ID: 24441874
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.
    Morris P; Hurrell A; Shaw A; Zhang E; Beard P
    J Acoust Soc Am; 2009 Jun; 125(6):3611-22. PubMed ID: 19507943
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fabrication of an optical lens array using ultraviolet light and ultrasonication.
    Taniguchi S; Koyama D; Nakamura K; Matsukawa M
    Ultrasonics; 2015 Apr; 58():22-6. PubMed ID: 25497498
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Trapping of microparticles in the near field of an ultrasonic transducer.
    Lilliehorn T; Simu U; Nilsson M; Almqvist M; Stepinski T; Laurell T; Nilsson J; Johansson S
    Ultrasonics; 2005 Mar; 43(5):293-303. PubMed ID: 15737379
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On the acoustic vaporization of micrometer-sized droplets.
    Kripfgans OD; Fabiilli ML; Carson PL; Fowlkes JB
    J Acoust Soc Am; 2004 Jul; 116(1):272-81. PubMed ID: 15295987
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasonic imaging using air-coupled P(VDF/TrFE) transducers at 2 MHz.
    Takahashi S; Ohigashi H
    Ultrasonics; 2009 May; 49(4-5):495-8. PubMed ID: 19215951
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An adjustable multi-scale single beam acoustic tweezers based on ultrahigh frequency ultrasonic transducer.
    Chen X; Lam KH; Chen R; Chen Z; Yu P; Chen Z; Shung KK; Zhou Q
    Biotechnol Bioeng; 2017 Nov; 114(11):2637-2647. PubMed ID: 28654158
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microfabricated 1-3 composite acoustic matching layers for 15 MHz transducers.
    Manh T; Jensen GU; Johansen TF; Hoff L
    Ultrasonics; 2013 Aug; 53(6):1141-9. PubMed ID: 23522684
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A single transducer transaxial compression technique for the estimation of sound speed in biological tissues.
    Ophir J; Moriya T; Yazdi Y
    Ultrason Imaging; 1991 Jul; 13(3):269-79. PubMed ID: 1957424
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modeling the thermo-acoustic effects of thermal-dependent speed of sound and acoustic absorption of biological tissues during focused ultrasound hyperthermia.
    López-Haro SA; Gutiérrez MI; Vera A; Leija L
    J Med Ultrason (2001); 2015 Oct; 42(4):489-98. PubMed ID: 26576973
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acoustic and Thermal Characterization of Therapeutic Ultrasonic Langevin Transducers under Continuous- and Pulsed Wave Excitations.
    Kim J; Lee J
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nonlinear acoustic properties of ex vivo bovine liver and the effects of temperature and denaturation.
    Jackson EJ; Coussios CC; Cleveland RO
    Phys Med Biol; 2014 Jun; 59(12):3223-38. PubMed ID: 24862475
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.