These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 251089)

  • 1. Guidelines for cleaning and disinfection of flexible fiberoptic endoscopes (FFE) used in GI endoscopy.
    AORN J; 1978 Nov; 28(5):907, 910. PubMed ID: 251089
    [No Abstract]   [Full Text] [Related]  

  • 2. Cleaning and disinfection of flexible fiberoptic endoscopes (FFE) used in gastrointestinal endoscopy.
    Hedrick E
    APIC; 1978 Dec; 6(4):8-9. PubMed ID: 10239938
    [No Abstract]   [Full Text] [Related]  

  • 3. Experiences and problems in the disinfection of fibre endoscopes.
    Lindstaedt H; Krizek L; Miederer SE; Botzenhart K
    Endoscopy; 1978 May; 10(2):80-5. PubMed ID: 658032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying.
    Gerding DN; Peterson LR; Vennes JA
    Gastroenterology; 1982 Sep; 83(3):613-8. PubMed ID: 6807738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Disinfection procedures of fiberscopes in endoscopy departments.
    Tolon M; Thofern E; Miederer SE
    Endoscopy; 1976 Feb; 8(1):24-9. PubMed ID: 799960
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The handling of fiber endoscopy--errors in manipulation, care and disinfection].
    Koelsch KA; Grenzbach M; Kuhn H
    Dtsch Z Verdau Stoffwechselkr; 1977; 37(3):133-42. PubMed ID: 608436
    [No Abstract]   [Full Text] [Related]  

  • 7. The cleaning and disinfection of flexible endoscopes and their accessories.
    Gray R
    NATNEWS; 1982 Sep; 19(9):30-2. PubMed ID: 6922404
    [No Abstract]   [Full Text] [Related]  

  • 8. Disinfection of a new generation of fibre-endoscopes.
    Meuwissen SG; Rozendaal B; Taal C; Rijsberman W; MacLaren DM
    J Hosp Infect; 1984 Dec; 5(4):460-1. PubMed ID: 6085105
    [No Abstract]   [Full Text] [Related]  

  • 9. [Disinfection and sterilization in gastroenterologic endoscopy].
    Kratzsch KH; Baumgarten R; Schentke KU; Liebe S
    Z Arztl Fortbild (Jena); 1987; 81(12):611-2. PubMed ID: 3660870
    [No Abstract]   [Full Text] [Related]  

  • 10. Bacteriological efficiency of a standardized cleansing and disinfection technique for duodenoscopes.
    Schenk J; Riemann JF; Gräf W
    Endoscopy; 1978 May; 10(2):75-9. PubMed ID: 658031
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bacterial contamination of fibreoptic endoscopes.
    Jepsen OB
    J Hosp Infect; 1980 Sep; 1(3):271. PubMed ID: 6182222
    [No Abstract]   [Full Text] [Related]  

  • 12. A simple method for cleaning flexible fibreoptic endoscopes by 'all-channel perfusion'.
    Meuwissen SG; MacLaren DM; Rijsberman W; Boshuizen K
    J Hosp Infect; 1983 Mar; 4(1):81-6. PubMed ID: 6190891
    [No Abstract]   [Full Text] [Related]  

  • 13. Gas sterilization of fiber endoscopes.
    Ujeyl AK; Wurbs D; Adam W; Classen M
    Endoscopy; 1978 May; 10(2):71-4. PubMed ID: 95946
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Contamination of fibroscopes and their disinfection].
    Kryszewski A
    Pol Tyg Lek; 1988 Mar 21-28; 43(12-13):429-32. PubMed ID: 3412977
    [No Abstract]   [Full Text] [Related]  

  • 15. Sterilization or disinfection of flexible fiberoptic endoscopes.
    Bond WW; Favero MS; Mackel DC; Mallison GF
    AORN J; 1979 Aug; 30(2):350, 352. PubMed ID: 258586
    [No Abstract]   [Full Text] [Related]  

  • 16. Fiberoptic endoscopes: disinfection or sterilization? Is the disinfection/sterilization debate resolved?
    Washington JA
    Same Day Surg; 1978 Mar; 2(3):62-4. PubMed ID: 10307120
    [No Abstract]   [Full Text] [Related]  

  • 17. Virus transmission via fiberoptic endoscope: recommended disinfection.
    Bond WW
    Md Med J; 1988 Jul; 37(7):497-8. PubMed ID: 3172995
    [No Abstract]   [Full Text] [Related]  

  • 18. Recent advances in the cleaning and disinfection of fibrescopes.
    Babb JR; Bradley CR; Deverill CE; Ayliffe GA; Melikian V
    J Hosp Infect; 1981 Dec; 2(4):329-40. PubMed ID: 6175689
    [No Abstract]   [Full Text] [Related]  

  • 19. Cleaning, disinfecting procedures help control spread of infection.
    Crow S
    Hospitals; 1978 Dec; 52(23):111-3. PubMed ID: 700657
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Disinfection of upper gastrointestinal fibreoptic endoscopy equipment: an evaluation of a cetrimide chlorhexidine solution and glutaraldehyde.
    Carr-Locke DL; Clayton P
    Gut; 1978 Oct; 19(10):916-22. PubMed ID: 101424
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.