These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Rapid and sensitive cardiac troponin I immunoassay based on fluorescent europium(III)-chelate-dyed nanoparticles. Järvenpää ML; Kuningas K; Niemi I; Hedberg P; Ristiniemi N; Pettersson K; Lövgren T Clin Chim Acta; 2012 Dec; 414():70-5. PubMed ID: 22975206 [TBL] [Abstract][Full Text] [Related]
5. Analytical performance and clinical utility of a sensitive immunoassay for determination of human cardiac troponin I. Davies E; Gawad Y; Takahashi M; Shi Q; Lam P; Styba G; Lau A; Heeschen C; Usategui M; Jackowski G Clin Biochem; 1997 Aug; 30(6):479-90. PubMed ID: 9316743 [TBL] [Abstract][Full Text] [Related]
6. Utilization of recombinant Fab fragments in a cTnI immunoassay conducted in spot wells. Ylikotila J; Hellström JL; Eriksson S; Vehniäinen M; Välimaa L; Takalo H; Bereznikova A; Pettersson K Clin Biochem; 2006 Aug; 39(8):843-50. PubMed ID: 16806144 [TBL] [Abstract][Full Text] [Related]
7. Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions. Hyytiä H; Heikkilä T; Hedberg P; Puolakanaho T; Pettersson K Clin Biochem; 2015 Mar; 48(4-5):313-7. PubMed ID: 25583092 [TBL] [Abstract][Full Text] [Related]
8. Extension of dynamic range of sensitive nanoparticle-based immunoassays. Hyytiä H; Ristiniemi N; Laitinen P; Lövgren T; Pettersson K Anal Biochem; 2014 Feb; 446():82-6. PubMed ID: 24211398 [TBL] [Abstract][Full Text] [Related]
9. Comparison of cardiac troponin I immunoassays variably affected by circulating autoantibodies. Eriksson S; Ilva T; Becker C; Lund J; Porela P; Pulkki K; Voipio-Pulkki LM; Pettersson K Clin Chem; 2005 May; 51(5):848-55. PubMed ID: 15718488 [TBL] [Abstract][Full Text] [Related]
10. Application of recombinant antibody fragments for troponin I measurements. Altshuler EP; Vylegzhanina AV; Katrukha IA; Bereznikova AV; Serebryanaya DV Biochemistry (Mosc); 2012 Dec; 77(12):1362-7. PubMed ID: 23244731 [TBL] [Abstract][Full Text] [Related]
12. Fabrication of anionic sulfate-functionalized nanoparticles as an immunosensor by protein immobilization. Kim S; Pyo HB; Ko SH; Ah CS; Kim A; Kim WJ Langmuir; 2010 May; 26(10):7355-64. PubMed ID: 20205399 [TBL] [Abstract][Full Text] [Related]
13. Effect of Biotin on Cardiac Troponin I and High Sensitivity Cardiac Troponin I Assays on Vista 1500 and ADVIA Centaur Analyzer. Dasgupta A; Khalil S Ann Clin Lab Sci; 2021 Jan; 51(1):102-105. PubMed ID: 33653787 [TBL] [Abstract][Full Text] [Related]
14. Sensitive and quantitative detection of cardiac troponin I with upconverting nanoparticle lateral flow test with minimized interference. Bayoumy S; Martiskainen I; Heikkilä T; Rautanen C; Hedberg P; Hyytiä H; Wittfooth S; Pettersson K Sci Rep; 2021 Sep; 11(1):18698. PubMed ID: 34548577 [TBL] [Abstract][Full Text] [Related]
15. Monoclonal Antibodies Against Human Cardiac Troponin I for Immunoassays II. Lee G; Liu S Monoclon Antib Immunodiagn Immunother; 2015 Jun; 34(3):169-73. PubMed ID: 26090594 [TBL] [Abstract][Full Text] [Related]
16. Use of a dual monoclonal solid phase and a polyclonal detector to create an immunoassay for the detection of human cardiac troponin I. Oh SK; Foster K; Datta P; Orswell M; Tasaico K; Mai X; Connolly P; Reamer R; Walsh R; Yang G; Barlow E; Bluestein B; Parsons G Clin Biochem; 2000 Jun; 33(4):255-62. PubMed ID: 10936582 [TBL] [Abstract][Full Text] [Related]
17. A sandwich enzyme immunoassay for cardiac troponin I. Suetomi K; Takahama K Nihon Hoigaku Zasshi; 1995 Feb; 49(1):26-32. PubMed ID: 7723197 [TBL] [Abstract][Full Text] [Related]
18. Negative interference in cardiac troponin I immunoassays from a frequently occurring serum and plasma component. Eriksson S; Junikka M; Laitinen P; Majamaa-Voltti K; Alfthan H; Pettersson K Clin Chem; 2003 Jul; 49(7):1095-104. PubMed ID: 12816906 [TBL] [Abstract][Full Text] [Related]
19. One-Step Digital Immunoassay for Rapid and Sensitive Detection of Cardiac Troponin I. Wang Y; Yang Y; Chen C; Wang S; Wang H; Jing W; Tao N ACS Sens; 2020 Apr; 5(4):1126-1131. PubMed ID: 32180397 [TBL] [Abstract][Full Text] [Related]
20. Multicenter evaluation of analytical performance of the Liaison troponin I assay. Pagani F; Stefini F; Chapelle JP; Lefèvre G; Graïne H; Luthe H; Engelmayer J; Panteghini M Clin Biochem; 2004 Sep; 37(9):750-7. PubMed ID: 15329312 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]