148 related articles for article (PubMed ID: 25113265)
1. Editor's Spotlight/Take 5: Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.
Abdel MP; Leopold SS
Clin Orthop Relat Res; 2014 Oct; 472(10):2909-12. PubMed ID: 25113265
[No Abstract] [Full Text] [Related]
2. Small improvements in mechanical axis alignment achieved with MRI versus CT-based patient-specific instruments in TKA: a randomized clinical trial.
Pfitzner T; Abdel MP; von Roth P; Perka C; Hommel H
Clin Orthop Relat Res; 2014 Oct; 472(10):2913-22. PubMed ID: 25024031
[TBL] [Abstract][Full Text] [Related]
3. Editorial: Our love affair with technology and the choices we make.
Leopold SS
Clin Orthop Relat Res; 2014 Oct; 472(10):2907-8. PubMed ID: 25099265
[No Abstract] [Full Text] [Related]
4. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.
Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP
Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929
[TBL] [Abstract][Full Text] [Related]
5. 2017 Chitranjan S. Ranawat Award: Does Computer Navigation in Knee Arthroplasty Improve Functional Outcomes in Young Patients? A Randomized Study.
Kim YH; Park JW; Kim JS
Clin Orthop Relat Res; 2018 Jan; 476(1):6-15. PubMed ID: 29389753
[TBL] [Abstract][Full Text] [Related]
6. MRI is more accurate than CT for patient-specific total knee arthroplasty.
Frye BM; Najim AA; Adams JB; Berend KR; Lombardi AV
Knee; 2015 Dec; 22(6):609-12. PubMed ID: 25813758
[TBL] [Abstract][Full Text] [Related]
7. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.
Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E
Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759
[TBL] [Abstract][Full Text] [Related]
8. Do patient-specific guides improve coronal alignment in total knee arthroplasty?
Nunley RM; Ellison BS; Zhu J; Ruh EL; Howell SM; Barrack RL
Clin Orthop Relat Res; 2012 Mar; 470(3):895-902. PubMed ID: 22183477
[TBL] [Abstract][Full Text] [Related]
9. Comparable clinical outcome and implant longevity after CT- or MRI-based patient-specific instruments for total knee arthroplasty: a 2-year follow-up of a RCT.
Thijs E; Theeuwen D; Boonen B; van Haaren E; Hendrickx R; Vos R; Borghans R; Kort N; Schotanus MGM
Knee Surg Sports Traumatol Arthrosc; 2020 Jun; 28(6):1821-1826. PubMed ID: 31270591
[TBL] [Abstract][Full Text] [Related]
10. The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis.
Rivière C; Iranpour F; Harris S; Auvinet E; Aframian A; Chabrand P; Cobb J
Orthop Traumatol Surg Res; 2017 Nov; 103(7):1069-1073. PubMed ID: 28870873
[TBL] [Abstract][Full Text] [Related]
11. A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer: a randomised controlled trial.
Schotanus MG; Sollie R; van Haaren EH; Hendrickx RP; Jansen EJ; Kort NP
Bone Joint J; 2016 Jun; 98-B(6):786-92. PubMed ID: 27235521
[TBL] [Abstract][Full Text] [Related]
12. Patient-specific instrumentation does not improve alignment in total knee arthroplasty.
Russell R; Brown T; Huo M; Jones R
J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis.
An VV; Sivakumar BS; Phan K; Levy YD; Bruce WJ
J Orthop Sci; 2017 Jan; 22(1):116-120. PubMed ID: 27823847
[TBL] [Abstract][Full Text] [Related]
14. Component position alignment with patient-specific jigs in total knee arthroplasty.
Moopanar TR; Amaranath JE; Sorial RM
ANZ J Surg; 2014 Sep; 84(9):628-32. PubMed ID: 24946273
[TBL] [Abstract][Full Text] [Related]
15. Intra-operative results and radiological outcome of conventional and patient-specific surgery in total knee arthroplasty: a multicentre, randomised controlled trial.
Boonen B; Schotanus MG; Kerens B; van der Weegen W; van Drumpt RA; Kort NP
Knee Surg Sports Traumatol Arthrosc; 2013 Oct; 21(10):2206-12. PubMed ID: 23928929
[TBL] [Abstract][Full Text] [Related]
16. Is TKA using patient-specific instruments comparable to conventional TKA? A randomized controlled study of one system.
Roh YW; Kim TW; Lee S; Seong SC; Lee MC
Clin Orthop Relat Res; 2013 Dec; 471(12):3988-95. PubMed ID: 23907610
[TBL] [Abstract][Full Text] [Related]
17. Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty.
Voleti PB; Hamula MJ; Baldwin KD; Lee GC
J Arthroplasty; 2014 Sep; 29(9):1709-12. PubMed ID: 24961893
[TBL] [Abstract][Full Text] [Related]
18. An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements.
Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1580-1586. PubMed ID: 30066018
[TBL] [Abstract][Full Text] [Related]
19. Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.
Yamamura K; Minoda Y; Sugama R; Ohta Y; Nakamura S; Ueyama H; Nakamura H
Knee Surg Sports Traumatol Arthrosc; 2020 May; 28(5):1560-1567. PubMed ID: 31240377
[TBL] [Abstract][Full Text] [Related]
20. Mechanical alignment technique for TKA: Are there intrinsic technical limitations?
Rivière C; Iranpour F; Auvinet E; Aframian A; Asare K; Harris S; Cobb J; Parratte S
Orthop Traumatol Surg Res; 2017 Nov; 103(7):1057-1067. PubMed ID: 28888523
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]