These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 25118619)

  • 1. Laser desorption with corona discharge ion mobility spectrometry for direct surface detection of explosives.
    Sabo M; Malásková M; Matejčík S
    Analyst; 2014 Oct; 139(20):5112-7. PubMed ID: 25118619
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge.
    Na N; Zhang C; Zhao M; Zhang S; Yang C; Fang X; Zhang X
    J Mass Spectrom; 2007 Aug; 42(8):1079-85. PubMed ID: 17618527
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ambient pressure laser desorption and laser-induced acoustic desorption ion mobility spectrometry detection of explosives.
    Ehlert S; Walte A; Zimmermann R
    Anal Chem; 2013 Nov; 85(22):11047-53. PubMed ID: 24116702
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry.
    Lee J; Park S; Cho SG; Goh EM; Lee S; Koh SS; Kim J
    Talanta; 2014 Mar; 120():64-70. PubMed ID: 24468343
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Desorption electrospray ionization of explosives on surfaces: sensitivity and selectivity enhancement by reactive desorption electrospray ionization.
    Cotte-Rodríguez I; Takáts Z; Talaty N; Chen H; Cooks RG
    Anal Chem; 2005 Nov; 77(21):6755-64. PubMed ID: 16255571
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Direct detection of explosives on solid surfaces by low temperature plasma desorption mass spectrometry.
    Zhang Y; Ma X; Zhang S; Yang C; Ouyang Z; Zhang X
    Analyst; 2009 Jan; 134(1):176-81. PubMed ID: 19082190
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of 2,4,6-trinitrotoluene, pentaerythritol tetranitrate and cyclo-1,3,5-trimethylene-2,4,6-trinitramine using negative corona discharge ion mobility spectrometry.
    Khayamian T; Tabrizchi M; Jafari MT
    Talanta; 2003 Feb; 59(2):327-33. PubMed ID: 18968915
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of explosives by positive corona discharge ion mobility spectrometry.
    Tabrizchi M; Ilbeigi V
    J Hazard Mater; 2010 Apr; 176(1-3):692-6. PubMed ID: 20004055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modular ion mobility spectrometer for explosives detection using corona ionization.
    Roscioli KM; Davis E; Siems WF; Mariano A; Su W; Guharay SK; Hill HH
    Anal Chem; 2011 Aug; 83(15):5965-71. PubMed ID: 21682306
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid identification and desorption mechanisms of nitrogen-based explosives by ambient micro-fabricated glow discharge plasma desorption/ionization (MFGDP) mass spectrometry.
    Tian C; Yin J; Zhao Z; Zhang Y; Duan Y
    Talanta; 2017 May; 167():75-85. PubMed ID: 28340788
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of explosives and related compounds by low-temperature plasma ambient ionization mass spectrometry.
    Garcia-Reyes JF; Harper JD; Salazar GA; Charipar NA; Ouyang Z; Cooks RG
    Anal Chem; 2011 Feb; 83(3):1084-92. PubMed ID: 21174437
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of explosives using a hollow cathode discharge ion source.
    Habib A; Chen LC; Usmanov DT; Yu Z; Hiraoka K
    Rapid Commun Mass Spectrom; 2015 Apr; 29(7):601-10. PubMed ID: 26212277
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laser desorption-ion mobility spectrometry as a useful tool for imaging of thin layer chromatography surface.
    Ilbeigi V; Sabo M; Valadbeigi Y; Matejcik S; Tabrizchi M
    J Chromatogr A; 2016 Aug; 1459():145-151. PubMed ID: 27397925
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stir-bar sorptive extraction and thermal desorption-ion mobility spectrometry for the determination of trinitrotoluene and l,3,5-trinitro-l,3,5-triazine in water samples.
    Lokhnauth JK; Snow NH
    J Chromatogr A; 2006 Feb; 1105(1-2):33-8. PubMed ID: 16249003
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimized thermal desorption for improved sensitivity in trace explosives detection by ion mobility spectrometry.
    Najarro M; Dávila Morris ME; Staymates ME; Fletcher R; Gillen G
    Analyst; 2012 Jun; 137(11):2614-22. PubMed ID: 22498665
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Atmospheric pressure chemical ionization of explosives using alternating current corona discharge ion source.
    Usmanov DT; Chen LC; Yu Z; Yamabe S; Sakaki S; Hiraoka K
    J Mass Spectrom; 2015 Apr; 50(4):651-61. PubMed ID: 26149109
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dopant-assisted negative photoionization ion mobility spectrometry for sensitive detection of explosives.
    Cheng S; Dou J; Wang W; Chen C; Hua L; Zhou Q; Hou K; Li J; Li H
    Anal Chem; 2013 Jan; 85(1):319-26. PubMed ID: 23199155
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of explosives in vapor phase by field asymmetric ion mobility spectrometry with dopant-assisted laser ionization.
    Kostarev VA; Kotkovskii GE; Chistyakov AA; Akmalov AE
    Talanta; 2022 Aug; 245():123414. PubMed ID: 35487080
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved quantitative analysis of ion mobility spectrometry by chemometric multivariate calibration.
    Fraga CG; Kerr DR; Atkinson DA
    Analyst; 2009 Nov; 134(11):2329-37. PubMed ID: 19838423
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detection of explosives using negative ion mobility spectrometry in air based on dopant-assisted thermal ionization.
    Shahraki H; Tabrizchi M; Farrokhpor H
    J Hazard Mater; 2018 Sep; 357():1-9. PubMed ID: 29859459
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.