BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

236 related articles for article (PubMed ID: 25124155)

  • 1. NIR spectroscopic method for the in-line moisture assessment during drying in a six-segmented fluid bed dryer of a continuous tablet production line: Validation of quantifying abilities and uncertainty assessment.
    Fonteyne M; Arruabarrena J; de Beer J; Hellings M; Van Den Kerkhof T; Burggraeve A; Vervaet C; Remon JP; De Beer T
    J Pharm Biomed Anal; 2014 Nov; 100():21-27. PubMed ID: 25124155
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Moisture and drug solid-state monitoring during a continuous drying process using empirical and mass balance models.
    Fonteyne M; Gildemyn D; Peeters E; Mortier ST; Vercruysse J; Gernaey KV; Vervaet C; Remon JP; Nopens I; De Beer T
    Eur J Pharm Biopharm; 2014 Aug; 87(3):616-28. PubMed ID: 24613541
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In-line multipoint near-infrared spectroscopy for moisture content quantification during freeze-drying.
    Kauppinen A; Toiviainen M; Korhonen O; Aaltonen J; Järvinen K; Paaso J; Juuti M; Ketolainen J
    Anal Chem; 2013 Feb; 85(4):2377-84. PubMed ID: 23351045
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of a continuous twin screw granulation and drying system during formulation development and process optimization.
    Vercruysse J; Peeters E; Fonteyne M; Cappuyns P; Delaet U; Van Assche I; De Beer T; Remon JP; Vervaet C
    Eur J Pharm Biopharm; 2015 Jan; 89():239-47. PubMed ID: 25528462
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dehydration studies using a novel multichamber microscale fluid bed dryer with in-line near-infrared measurement.
    Räsänen E; Rantanen J; Mannermaa JP; Yliruusi J; Vuorela H
    J Pharm Sci; 2003 Oct; 92(10):2074-81. PubMed ID: 14502546
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and validation of an in-line NIR spectroscopic method for continuous blend potency determination in the feed frame of a tablet press.
    De Leersnyder F; Peeters E; Djalabi H; Vanhoorne V; Van Snick B; Hong K; Hammond S; Liu AY; Ziemons E; Vervaet C; De Beer T
    J Pharm Biomed Anal; 2018 Mar; 151():274-283. PubMed ID: 29413975
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of powder phenomena inside a Fette 3090 feed frame using in-line NIR spectroscopy.
    Mateo-Ortiz D; Colon Y; Romañach RJ; Méndez R
    J Pharm Biomed Anal; 2014 Nov; 100():40-49. PubMed ID: 25128874
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of a multipoint near-infrared spectroscopy method for in-line moisture content analysis during freeze-drying.
    Kauppinen A; Toiviainen M; Lehtonen M; Järvinen K; Paaso J; Juuti M; Ketolainen J
    J Pharm Biomed Anal; 2014 Jul; 95():229-37. PubMed ID: 24699368
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A GLUE uncertainty analysis of a drying model of pharmaceutical granules.
    Mortier ST; Van Hoey S; Cierkens K; Gernaey KV; Seuntjens P; De Baets B; De Beer T; Nopens I
    Eur J Pharm Biopharm; 2013 Nov; 85(3 Pt B):984-95. PubMed ID: 23542609
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Method transfer of a near-infrared spectroscopic method for blend uniformity in a poorly flowing and hygroscopic blend.
    Alvarado-Hernández BB; Scicolone JV; Ortega-Zuniga C; Román-Ospino AD; Colón-Lugo YM; Aymat E; Sánchez E; Muzzio FJ; Romañach RJ
    J Pharm Biomed Anal; 2020 Feb; 180():113054. PubMed ID: 31881395
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional moisture content and size measurement of pharmaceutical granules after fluid bed drying using near-infrared chemical imaging.
    Ghijs M; Vanbillemont B; Nicolaï N; De Beer T; Nopens I
    Int J Pharm; 2021 Feb; 595():120069. PubMed ID: 33421586
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dynamic calibration for the in-line NIR monitoring of film thickness of pharmaceutical tablets processed in a fluid-bed coater.
    Lee MJ; Park CR; Kim AY; Kwon BS; Bang KH; Cho YS; Jeong MY; Choi GJ
    J Pharm Sci; 2010 Jan; 99(1):325-35. PubMed ID: 19455613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On-line moisture detection for a microwave vacuum dryer.
    White JG
    Pharm Res; 1994 May; 11(5):728-32. PubMed ID: 8058644
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel in-line NIR spectroscopy application for the monitoring of tablet film coating in an industrial scale process.
    Möltgen CV; Puchert T; Menezes JC; Lochmann D; Reich G
    Talanta; 2012 Apr; 92():26-37. PubMed ID: 22385804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Real-time process monitoring in a semi-continuous fluid-bed dryer - microwave resonance technology versus near-infrared spectroscopy.
    Peters J; Teske A; Taute W; Döscher C; Höft M; Knöchel R; Breitkreutz J
    Int J Pharm; 2018 Feb; 537(1-2):193-201. PubMed ID: 29288092
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In-line quantification of micronized drug and excipients in tablets by near infrared (NIR) spectroscopy: Real time monitoring of tabletting process.
    Karande AD; Heng PW; Liew CV
    Int J Pharm; 2010 Aug; 396(1-2):63-74. PubMed ID: 20558264
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Process analytical technology in continuous manufacturing of a commercial pharmaceutical product.
    Vargas JM; Nielsen S; Cárdenas V; Gonzalez A; Aymat EY; Almodovar E; Classe G; Colón Y; Sanchez E; Romañach RJ
    Int J Pharm; 2018 Mar; 538(1-2):167-178. PubMed ID: 29355655
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In-line quantification of drug and excipients in cohesive powder blends by near infrared spectroscopy.
    Liew CV; Karande AD; Heng PW
    Int J Pharm; 2010 Feb; 386(1-2):138-48. PubMed ID: 19922776
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Inline real-time near-infrared granule moisture measurements of a continuous granulation-drying-milling process.
    Chablani L; Taylor MK; Mehrotra A; Rameas P; Stagner WC
    AAPS PharmSciTech; 2011 Dec; 12(4):1050-5. PubMed ID: 21842310
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of powder blend uniformity: Comparison of real-time NIR blend monitoring with stratified sampling in combination with HPLC and at-line NIR Chemical Imaging.
    Bakri B; Weimer M; Hauck G; Reich G
    Eur J Pharm Biopharm; 2015 Nov; 97(Pt A):78-89. PubMed ID: 26455421
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.