These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

374 related articles for article (PubMed ID: 25124863)

  • 1. Reliability and validity testing of automated scoring in obstructive sleep apnea diagnosis with the Embletta X100.
    Park DY; Kim HJ; Kim CH; Kim YS; Choi JH; Hong SY; Jung JJ; Lee KI; Lee HS
    Laryngoscope; 2015 Feb; 125(2):493-7. PubMed ID: 25124863
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Perioperative practical experiences in using a level 2 portable polysomnography.
    Chung F; Liao P; Sun Y; Amirshahi B; Fazel H; Shapiro CM; Elsaid H
    Sleep Breath; 2011 Sep; 15(3):367-75. PubMed ID: 20232260
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Misclassification of OSA severity with automated scoring of home sleep recordings.
    Aurora RN; Swartz R; Punjabi NM
    Chest; 2015 Mar; 147(3):719-727. PubMed ID: 25411804
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine.
    Collop NA; Anderson WM; Boehlecke B; Claman D; Goldberg R; Gottlieb DJ; Hudgel D; Sateia M; Schwab R;
    J Clin Sleep Med; 2007 Dec; 3(7):737-47. PubMed ID: 18198809
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Is the Nox-T3 device scoring algorithm accurate enough for the diagnosis of obstructive sleep apnea?
    Valério MP; Pereira S; Moita J; Teixeira F; Travassos C; Coutinho AS; Rodrigues DM
    Adv Respir Med; 2021; 89(3):262-267. PubMed ID: 34196378
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validation of the Nox-T3 Portable Monitor for Diagnosis of Obstructive Sleep Apnea in Chinese Adults.
    Xu L; Han F; Keenan BT; Kneeland-Szanto E; Yan H; Dong X; Chang Y; Zhao L; Zhang X; Li J; Pack AI; Kuna ST
    J Clin Sleep Med; 2017 May; 13(5):675-683. PubMed ID: 28356181
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Differences between manual and automatic analysis in determining the severity of obstructive sleep apnea using home sleep apnea testing.
    Labarca G; Dreyse J; Salas C; Contreras A; Nazar G; Gaete MI; Jorquera J
    Sleep Med; 2018 Jul; 47():66-71. PubMed ID: 29772418
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Home sleep apnea testing: an accuracy study.
    Zancanella E; do Prado LF; de Carvalho LB; Machado Júnior AJ; Crespo AN; do Prado GF
    Sleep Breath; 2022 Mar; 26(1):117-123. PubMed ID: 33837916
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of a 2-channel portable device and a predictive model to screen for obstructive sleep apnea in a laboratory environment.
    Zou J; Meng L; Liu Y; Xu X; Liu S; Guan J; Yin S; Yi H
    Respir Care; 2015 Mar; 60(3):356-62. PubMed ID: 25406349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Assessment of a portable monitoring device Watch PAT 200 in the diagnosis of obstructive sleep apnea hypopnea syndrome].
    Li W; Wang R; Huang D; Liu X; Jin W; Yang S
    Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2013 Dec; 27(24):1343-7. PubMed ID: 24669681
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100.
    Choi JH; Kim EJ; Kim YS; Choi J; Kim TH; Kwon SY; Lee HM; Lee SH; Shin C; Lee SH
    Acta Otolaryngol; 2010 Jul; 130(7):838-43. PubMed ID: 20082567
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of a portable device based on peripheral arterial tone in the detection of obstructive sleep apnea].
    Zhang J; Wang CY; Wang NY; Liu JQ; Du JY; Zhou GX; Yan ZF; Wen XH; Li L; Liu JF
    Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2012 Feb; 47(2):112-6. PubMed ID: 22455808
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A preliminary study on application of portable monitoring for diagnosis of obstructive sleep apnea.
    Yin M; Miyazaki S; Itasaka Y; Shibata Y; Abe T; Miyoshi A; Ishikawa K; Togawa K
    Auris Nasus Larynx; 2005 Jun; 32(2):151-6. PubMed ID: 15917172
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing.
    Pittman SD; MacDonald MM; Fogel RB; Malhotra A; Todros K; Levy B; Geva AB; White DP
    Sleep; 2004 Nov; 27(7):1394-403. PubMed ID: 15586793
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Respiratory polygraphy with actigraphy in the diagnosis of sleep apnea-hypopnea syndrome.
    García-Díaz E; Quintana-Gallego E; Ruiz A; Carmona-Bernal C; Sánchez-Armengol Á; Botebol-Benhamou G; Capote F
    Chest; 2007 Mar; 131(3):725-732. PubMed ID: 17356086
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Home sleep apnea testing: comparison of manual and automated scoring across international sleep centers.
    Magalang UJ; Johns JN; Wood KA; Mindel JW; Lim DC; Bittencourt LR; Chen NH; Cistulli PA; Gíslason T; Arnardottir ES; Penzel T; Tufik S; Pack AI
    Sleep Breath; 2019 Mar; 23(1):25-31. PubMed ID: 30203176
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An investigation of the validity of the Lifeshirt in comparison to standard polysomnography in the detection of obstructive sleep apnea.
    Goodrich S; Orr WC
    Sleep Med; 2009 Jan; 10(1):118-22. PubMed ID: 18083629
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.
    Punjabi NM; Shifa N; Dorffner G; Patil S; Pien G; Aurora RN
    Sleep; 2015 Oct; 38(10):1555-66. PubMed ID: 25902809
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Obstructive sleep apnoea syndrome: comparison between polysomnography and portable sleep monitoring based on jaw recordings.
    Cheliout-Heraut F; Senny F; Djouadi F; Ouayoun M; Bour F
    Neurophysiol Clin; 2011 Oct; 41(4):191-8. PubMed ID: 22078731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of automatic analysis of ambulatory recordings of nocturnal breathing disorders is significantly instrumentation dependent.
    Tiihonen P; Hukkanen T; Tuomilehto H; Mervaala E; Pääkkönen A; Töyräs J
    J Med Eng Technol; 2009; 33(5):386-93. PubMed ID: 19440918
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.