These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
85 related articles for article (PubMed ID: 25125009)
1. Neoatherosclerosis--a cause of late stent thrombosis? Tsay IM; Asrar ul Haq M; Hayat U; Goh CY; Ponnuthurai F; Barlis P Int J Cardiol; 2014 Nov; 177(1):e1-3. PubMed ID: 25125009 [No Abstract] [Full Text] [Related]
2. Acute stent thrombosis and atopy: implications for Kounis syndrome. Almpanis G; Mazarakis A; Tsigkas G; Koutsojannis C; Kounis GN; Kounis NG Int J Cardiol; 2010 Nov; 145(2):398-400. PubMed ID: 20537420 [No Abstract] [Full Text] [Related]
3. Optical frequency domain imaging to reveal an angiographically inapparent very late stent thrombosis as the cause of an acute coronary syndrome. Jaguszewski MJ; Kuest S; Templin C; Landmesser U J Am Coll Cardiol; 2012 Aug; 60(7):e11. PubMed ID: 22878172 [No Abstract] [Full Text] [Related]
4. Bare metal stent thrombosis and in-stent neoatherosclerosis. Yamaji K; Inoue K; Nakahashi T; Noguchi M; Domei T; Hyodo M; Soga Y; Shirai S; Ando K; Kondo K; Sakai K; Iwabuchi M; Yokoi H; Nosaka H; Nobuyoshi M; Kimura T Circ Cardiovasc Interv; 2012 Feb; 5(1):47-54. PubMed ID: 22253359 [TBL] [Abstract][Full Text] [Related]
5. Allergic reaction reveals a non-lethal late stent thrombosis. A new subtype of Kounis syndrome? Tsigkas G; Chouchoulis K; Theodoropoulos K; Kounis NG; Alexopoulos D Int J Cardiol; 2011 Jun; 149(2):281-282. PubMed ID: 21429602 [No Abstract] [Full Text] [Related]
6. Spatial heterogeneity of neoatherosclerosis and its relationship with neovascularization and adjacent plaque characteristics: optical coherence tomography study. Tian J; Ren X; Uemura S; Dauerman H; Prasad A; Toma C; Jia H; Abtahian F; Vergallo R; Hu S; McNulty I; Lee H; Lee S; Yu B; Jang IK Am Heart J; 2014 Jun; 167(6):884-92.e2. PubMed ID: 24890539 [TBL] [Abstract][Full Text] [Related]
7. In-stent neoatherosclerosis: a cause of late stent thrombosis in a patient with "full metal jacket" 15 years after implantation: insights from optical coherence tomography. Karanasos A; Ligthart JM; Regar E JACC Cardiovasc Interv; 2012 Jul; 5(7):799-800. PubMed ID: 22814787 [No Abstract] [Full Text] [Related]
8. Very late bare-metal stent thrombosis. A case report and review of the literature. Manjappa N; Agarwal A; Cavusoglu E J Invasive Cardiol; 2006 Jul; 18(7):E203-6. PubMed ID: 16816449 [TBL] [Abstract][Full Text] [Related]
10. Optical coherence tomography-based evaluation of in-stent neoatherosclerosis in lesions with more than 50% neointimal cross-sectional area stenosis. Lee SY; Shin DH; Mintz GS; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK EuroIntervention; 2013 Dec; 9(8):945-51. PubMed ID: 24384291 [TBL] [Abstract][Full Text] [Related]
11. The year in atherothrombosis. Sanz J; Moreno PR; Fuster V J Am Coll Cardiol; 2010 Apr; 55(14):1487-98. PubMed ID: 20359599 [No Abstract] [Full Text] [Related]
12. Are drug-eluting stents associated with a higher rate of late thrombosis than bare metal stents? Late stent thrombosis: a nuisance in both bare metal and drug-eluting stents. Serruys PW; Daemen J Circulation; 2007 Mar; 115(11):1433-9; discussion 1439. PubMed ID: 17344323 [No Abstract] [Full Text] [Related]
13. A rare mechanism of very late bare metal stent thrombosis--role of optical coherence imaging in its evaluation and management. Subban V; Bell B; Raffel OC; Small A; Savage M; Incani A; Walters DL Heart Lung Circ; 2014 Feb; 23(2):190-2. PubMed ID: 23721696 [TBL] [Abstract][Full Text] [Related]
14. The first report of late stent thrombosis leading to acute myocardial infarction in patient receiving the new endothelial progenitor cell capture stent. Rossi ML; Zavalloni D; Gasparini GL; Mango R; Belli G; Presbitero P Int J Cardiol; 2010 May; 141(1):e20-2. PubMed ID: 19135746 [TBL] [Abstract][Full Text] [Related]
15. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Camenzind E; Steg PG; Wijns W Circulation; 2007 Mar; 115(11):1440-55; discussion 1455. PubMed ID: 17344324 [No Abstract] [Full Text] [Related]
16. Peristrut microhemorrhages: a possible cause of in-stent neoatherosclerosis? Terzian Z; Gasser TC; Blackwell F; Hyafil F; Louedec L; Deschildre C; Ghodbane W; Dorent R; Nicoletti A; Morvan M; Nejjari M; Feldman L; Pavon-Djavid G; Michel JB Cardiovasc Pathol; 2017; 26():30-38. PubMed ID: 27865168 [TBL] [Abstract][Full Text] [Related]
17. Suboptimal stent deployment is associated with subacute stent thrombosis: optical coherence tomography insights from a multicenter matched study. From the CLI Foundation investigators: the CLI-THRO study. Prati F; Kodama T; Romagnoli E; Gatto L; Di Vito L; Ramazzotti V; Chisari A; Marco V; Cremonesi A; Parodi G; Albertucci M; Alfonso F Am Heart J; 2015 Feb; 169(2):249-56. PubMed ID: 25641534 [TBL] [Abstract][Full Text] [Related]
18. The risk of stent thrombosis in patients with acute coronary syndromes treated with bare-metal and drug-eluting stents. Kukreja N; Onuma Y; Garcia-Garcia HM; Daemen J; van Domburg R; Serruys PW; JACC Cardiovasc Interv; 2009 Jun; 2(6):534-41. PubMed ID: 19539258 [TBL] [Abstract][Full Text] [Related]
19. Optical coherence tomography findings during "evolving" stent thrombosis. Zakhem B; Fernandez-Ortiz A; Alfonso F J Invasive Cardiol; 2011 Sep; 23(9):E222-5. PubMed ID: 21891818 [TBL] [Abstract][Full Text] [Related]
20. Clinical features and outcomes of primary percutaneous coronary intervention for subacute stent thrombosis--a case series. Lee CH; Lemos PA; Serruys PW Int J Cardiol; 2005 Jan; 98(1):171-2. PubMed ID: 15676188 [No Abstract] [Full Text] [Related] [Next] [New Search]