These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 25125118)

  • 1. Correlation between electronic and corrosion properties of the passive oxide film on nitinol.
    Katić J; Metikoš-Huković M
    Acta Chim Slov; 2014; 61(2):350-6. PubMed ID: 25125118
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Semiconducting Behaviour and Corrosion Resistance of Passive Film on Corrosion-Resistant Steel Rebars.
    Lv S; Li K
    Materials (Basel); 2022 Oct; 15(21):. PubMed ID: 36363247
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of passive potential on the electronic property of the passive film formed on Ti in 0.1 M HCl solution during ultrasonic cavitation.
    Li DG; Wang JD; Chen DR; Liang P
    Ultrason Sonochem; 2016 Mar; 29():48-54. PubMed ID: 26584983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of electrodeposited undoped and doped thin ZnO passive films on zinc metal in alkaline HCO
    El-Taib Heakal F; Abd-Ellatif WR; Tantawy NS; Taha AA
    RSC Adv; 2018 Nov; 8(69):39321-39333. PubMed ID: 35558032
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The role of grain refinement and film formation potential on the electrochemical behavior of commercial pure titanium in Hank's physiological solution.
    Fattah-Alhosseini A; Imantalab O; Ansari G
    Mater Sci Eng C Mater Biol Appl; 2017 Feb; 71():827-834. PubMed ID: 27987778
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The electrochemical behavior of nitinol in simulated gastric fluid.
    Pound BG
    J Biomed Mater Res B Appl Biomater; 2017 Nov; 105(8):2394-2400. PubMed ID: 27571598
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrochemical fabrication and properties of highly ordered Fe-doped TiO2 nanotubes.
    Kyeremateng NA; Hornebecq V; Martinez H; Knauth P; Djenizian T
    Chemphyschem; 2012 Nov; 13(16):3707-13. PubMed ID: 22930465
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Corrosion behavior of micro-arc oxidation film on titanium in simulated body fluid].
    Sun GL; Chen JZ; Wang L; Shi YL
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2007 Aug; 42(8):501-4. PubMed ID: 18001597
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dynamic response of thin-film semiconductors to AC voltage perturbations.
    La Mantia F; Stojadinović J; Santamaria M; Di Quarto F
    Chemphyschem; 2012 Aug; 13(12):2910-8. PubMed ID: 22566168
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of the microstructure and topography on the barrier properties of oxide scales generated on blasted Ti6Al4V surfaces.
    Barranco V; Escudero ML; García-Alonso MC
    Acta Biomater; 2011 Jun; 7(6):2716-25. PubMed ID: 21382529
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of ultrasonic cavitation on passive film of stainless steel.
    Wang BC; Zhu JH
    Ultrason Sonochem; 2008 Mar; 15(3):239-43. PubMed ID: 17584517
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of fluoride on the physicochemical properties of anodic oxide films formed on titanium surfaces.
    Kong DS
    Langmuir; 2008 May; 24(10):5324-31. PubMed ID: 18442276
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of pH and temperature on the electrochemical and semiconducting properties of zinc in alkaline buffer media.
    El-Taib Heakal F; Abd-Ellatif WR; Tantawy NS; Taha AA
    RSC Adv; 2018 Jan; 8(7):3816-3827. PubMed ID: 35542935
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On the passive and semiconducting behavior of severely deformed pure titanium in Ringer's physiological solution at 37°C: A trial of the point defect model.
    Ansari G; Fattah-Alhosseini A
    Mater Sci Eng C Mater Biol Appl; 2017 Jun; 75():64-71. PubMed ID: 28415510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Structure and dielectric properties of electrochemically grown ZrO2 films.
    Gomez-Sanchez A; Katunar M; Schreiner W; Duffó G; Ceré S; Schiffrin DJ
    Acta Chim Slov; 2014; 61(2):316-27. PubMed ID: 25125115
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications.
    Oliveira NT; Guastaldi AC
    Acta Biomater; 2009 Jan; 5(1):399-405. PubMed ID: 18707926
    [TBL] [Abstract][Full Text] [Related]  

  • 17. One-step hydrothermal crystallization of a layered double hydroxide/alumina bilayer film on aluminum and its corrosion resistance properties.
    Guo X; Xu S; Zhao L; Lu W; Zhang F; Evans DG; Duan X
    Langmuir; 2009 Sep; 25(17):9894-7. PubMed ID: 19441823
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electronic properties and surface potential evaluations at the protein nano-biofilm/oxide interface: Impact on corrosion and biodegradation.
    Rahimi E; Offoiach R; Lekka M; Fedrizzi L
    Colloids Surf B Biointerfaces; 2022 Apr; 212():112346. PubMed ID: 35074638
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The electronic and chemical structure of the a-B3CO0.5:Hy-to-metal interface from photoemission spectroscopy: implications for Schottky barrier heights.
    Driver MS; Paquette MM; Karki S; Nordell BJ; Caruso AN
    J Phys Condens Matter; 2012 Nov; 24(44):445001. PubMed ID: 22976833
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions.
    Bai Y; Hao YL; Li SJ; Hao YQ; Yang R; Prima F
    Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2159-67. PubMed ID: 23498244
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.