BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1240 related articles for article (PubMed ID: 25125294)

  • 1. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.
    Natale A; Reddy VY; Monir G; Wilber DJ; Lindsay BD; McElderry HT; Kantipudi C; Mansour MC; Melby DP; Packer DL; Nakagawa H; Zhang B; Stagg RB; Boo LM; Marchlinski FE
    J Am Coll Cardiol; 2014 Aug; 64(7):647-56. PubMed ID: 25125294
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry.
    De Potter T; Van Herendael H; Balasubramaniam R; Wright M; Agarwal SC; Sanders P; Khaykin Y; Latcu DG; Maury P; Pani A; Hayes J; Kalman J; Nery P; Duncan E
    Europace; 2018 Nov; 20(FI_3):f410-f418. PubMed ID: 29315382
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Safety and efficiency of porous-tip contact-force catheter for drug-refractory symptomatic paroxysmal atrial fibrillation ablation: results from the SMART SF trial.
    Chinitz LA; Melby DP; Marchlinski FE; Delaughter C; Fishel RS; Monir G; Patel AM; Gibson DN; Athill CA; Ming Boo L; Stagg R; Natale A
    Europace; 2018 Nov; 20(FI_3):f392-f400. PubMed ID: 29016769
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation: A Multinational Multicenter Randomized Clinical Trial.
    Boersma LV; van der Voort P; Debruyne P; Dekker L; Simmers T; Rossenbacker T; Balt J; Wijffels M; Degreef Y
    Circ Arrhythm Electrophysiol; 2016 Apr; 9(4):e003151. PubMed ID: 27071830
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term safety and effectiveness of paroxysmal atrial fibrillation ablation using a porous tip contact force-sensing catheter from the SMART SF trial.
    Natale A; Monir G; Patel AM; Fishel RS; Marchlinski FE; Delaughter MC; Athill CA; Melby DP; Gonzalez MD; Hariharan R; Gidney B; Tan T; Chinitz LA
    J Interv Card Electrophysiol; 2021 Jun; 61(1):63-69. PubMed ID: 32462550
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study.
    Reddy VY; Dukkipati SR; Neuzil P; Natale A; Albenque JP; Kautzner J; Shah D; Michaud G; Wharton M; Harari D; Mahapatra S; Lambert H; Mansour M
    Circulation; 2015 Sep; 132(10):907-15. PubMed ID: 26260733
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results.
    Marijon E; Fazaa S; Narayanan K; Guy-Moyat B; Bouzeman A; Providencia R; Treguer F; Combes N; Bortone A; Boveda S; Combes S; Albenque JP
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):130-7. PubMed ID: 24433324
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-year outcomes and reconnection patterns after initial contact force guided pulmonary vein isolation for paroxysmal atrial fibrillation.
    Nair GM; Yeo C; MacDonald Z; Ainslie MP; Alqarawi WA; Nery PB; Redpath CJ; Sadek M; Spence S; Green MS; Birnie DH
    J Cardiovasc Electrophysiol; 2017 Sep; 28(9):984-993. PubMed ID: 28635046
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study.
    Andrade JG; Monir G; Pollak SJ; Khairy P; Dubuc M; Roy D; Talajic M; Deyell M; Rivard L; Thibault B; Guerra PG; Nattel S; Macle L
    Heart Rhythm; 2014 Nov; 11(11):1919-24. PubMed ID: 25068575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation.
    Buist TJ; Adiyaman A; Smit JJJ; Ramdat Misier AR; Elvan A
    Clin Res Cardiol; 2018 Jun; 107(6):498-506. PubMed ID: 29411114
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.
    Maurer T; Rottner L; Makimoto H; Reissmann B; Heeger CH; Lemes C; Fink T; Riedl J; Santoro F; Wohlmuth P; Volkmer M; Mathew S; Metzner A; Ouyang F; Kuck KH; Sohns C
    Clin Res Cardiol; 2018 Nov; 107(11):1003-1012. PubMed ID: 29740700
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I study.
    Neuzil P; Reddy VY; Kautzner J; Petru J; Wichterle D; Shah D; Lambert H; Yulzari A; Wissner E; Kuck KH
    Circ Arrhythm Electrophysiol; 2013 Apr; 6(2):327-33. PubMed ID: 23515263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Catheter-tissue contact force values do not impact mid-term clinical outcome following pulmonary vein isolation in patients with paroxysmal atrial fibrillation.
    Stabile G; Solimene F; Calò L; Anselmino M; Castro A; Pratola C; Golia P; Bottoni N; Grandinetti G; De Simone A; Schillaci V; Bertaglia E; De Ponti R
    J Interv Card Electrophysiol; 2015 Jan; 42(1):21-6. PubMed ID: 25378035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of biatrial defragmentation in patients with paroxysmal atrial fibrillation: results from a randomized prospective study.
    Nührich JM; Steven D; Berner I; Rostock T; Hoffmann B; Servatius H; Sultan A; Lüker J; Treszl A; Wegscheider K; Willems S
    Heart Rhythm; 2014 Sep; 11(9):1536-42. PubMed ID: 24907643
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation: Results From the Gap-Atrial Fibrillation-German Atrial Fibrillation Competence Network 1 Trial.
    Kuck KH; Hoffmann BA; Ernst S; Wegscheider K; Treszl A; Metzner A; Eckardt L; Lewalter T; Breithardt G; Willems S;
    Circ Arrhythm Electrophysiol; 2016 Jan; 9(1):e003337. PubMed ID: 26763226
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy and safety of the GOLD FORCE multicentre randomized clinical trial: multielectrode phased radiofrequency vs. irrigated radiofrequency single-tip catheter with contact force ablation for treatment of symptomatic paroxysmal atrial fibrillation.
    Wintgens LIS; Klaver MN; Maarse M; Spitzer SG; Langbein A; Swaans MJ; Van Dijk VF; Balt JC; Wijffels MCEF; Tijssen JGP; Elvan A; Boersma LVA
    Europace; 2021 Dec; 23(12):1931-1938. PubMed ID: 34279627
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Persistent Atrial Fibrillation Ablation With Contact Force-Sensing Catheter: The Prospective Multicenter PRECEPT Trial.
    Mansour M; Calkins H; Osorio J; Pollak SJ; Melby D; Marchlinski FE; Athill CA; Delaughter C; Patel AM; Gentlesk PJ; DeVille B; Macle L; Ellenbogen KA; Dukkipati SR; Reddy VY; Natale A
    JACC Clin Electrophysiol; 2020 Aug; 6(8):958-969. PubMed ID: 32819531
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual energy for pulmonary vein isolation using dual-energy focal ablation technology integrated with a three-dimensional mapping system: SmartfIRE 3-month results.
    Duytschaever M; Račkauskas G; De Potter T; Hansen J; Knecht S; Phlips T; Vijgen J; Scherr D; Szeplaki G; Van Herendael H; Kronborg MB; Berte B; Pürerfellner H; Lukac P
    Europace; 2024 May; 26(5):. PubMed ID: 38696675
    [TBL] [Abstract][Full Text] [Related]  

  • 19. nMARQ Ablation for Atrial Fibrillation: Results from a Multicenter Study.
    Mahida S; Hooks DA; Nentwich K; Ng GA; Grimaldi M; Shin DI; Derval N; Sacher F; Berte B; Yamashita S; Denis A; Hocini M; Deneke T; Haissaguerre M; Jais P
    J Cardiovasc Electrophysiol; 2015 Jul; 26(7):724-9. PubMed ID: 25916682
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 62.