These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 25140025)

  • 1. Inappropriate shocks due to subcutaneous air in a patient with a subcutaneous cardiac defibrillator.
    Zipse MM; Sauer WH; Varosy PD; Aleong RG; Nguyen DT
    Circ Arrhythm Electrophysiol; 2014 Aug; 7(4):768-70. PubMed ID: 25140025
    [No Abstract]   [Full Text] [Related]  

  • 2. Letter by Gamble et al regarding article, "inappropriate shocks due to subcutaneous air in a patient with a subcutaneous cardiac defibrillator".
    Gamble JH; Grogono J; Rajappan K; Betts TR; Bashir Y; Khiani R
    Circ Arrhythm Electrophysiol; 2014 Dec; 7(6):1281. PubMed ID: 25516592
    [No Abstract]   [Full Text] [Related]  

  • 3. Troubleshooting implantable cardioverter-defibrillator sensing problems II.
    Swerdlow CD; Asirvatham SJ; Ellenbogen KA; Friedman PA
    Circ Arrhythm Electrophysiol; 2015 Feb; 8(1):212-20. PubMed ID: 25691555
    [No Abstract]   [Full Text] [Related]  

  • 4. Inappropriate shock because of triple counting in a patient with a subcutaneous implantable cardioverter defibrillator corrected by initiation of dual site left ventricular pacing.
    van Gelder BM; Bracke FA; Simmers T
    Circ Arrhythm Electrophysiol; 2015 Feb; 8(1):239-40. PubMed ID: 25691559
    [No Abstract]   [Full Text] [Related]  

  • 5. Inappropriate implantable cardioverter-defibrillator shocks in a public swimming pool.
    Alzand BS; Leemput N; Willems R
    Europace; 2014 Aug; 16(8):1124. PubMed ID: 24192323
    [No Abstract]   [Full Text] [Related]  

  • 6. Troubleshooting implanted cardioverter defibrillator sensing problems I.
    Swerdlow CD; Asirvatham SJ; Ellenbogen KA; Friedman PA
    Circ Arrhythm Electrophysiol; 2014 Dec; 7(6):1237-61. PubMed ID: 25516582
    [No Abstract]   [Full Text] [Related]  

  • 7. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device.
    Francisco GM; Sharma S; Dougherty AH; Kantharia BK
    Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Subcutaneous implantable cardioverter-defibrillators and sternal wires: a cautionary tale.
    Winter J; Kohlmeier A; Shin DI; O'Connor S
    Circ Arrhythm Electrophysiol; 2014 Oct; 7(5):986-7. PubMed ID: 25336371
    [No Abstract]   [Full Text] [Related]  

  • 9. Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator.
    Adduci C; Spadoni L; Palano F; Francia P
    J Cardiovasc Electrophysiol; 2019 Aug; 30(8):1373-1374. PubMed ID: 31165543
    [No Abstract]   [Full Text] [Related]  

  • 10. Inappropriate implantable cardioverter-defibrillator shocks attributed to alternating-current leak in a swimming pool.
    Makaryus JN; Angert-Gilman J; Yacoub M; Patel A; Goldner B
    Tex Heart Inst J; 2014 Feb; 41(1):61-3. PubMed ID: 24512403
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A New Riata Lead Complication: Spontaneous Lead Tip Embolization.
    Nadeau PL; Philippon F; Sarrazin JF; Champagne J
    J Cardiovasc Electrophysiol; 2016 Feb; 27(2):234-5. PubMed ID: 26331700
    [No Abstract]   [Full Text] [Related]  

  • 12. Post-shock oversensing by a subcutaneous defibrillator resulting in inappropriate withholding of post-shock bradycardia pacing.
    Maass AH; Van Gelder IC
    Europace; 2014 Jul; 16(7):1032. PubMed ID: 24792457
    [No Abstract]   [Full Text] [Related]  

  • 13. Developing a crush: acute implantable cardioverter-defibrillator lead insulation break in a patient with multiple leads.
    Tilling L; Mason M
    Europace; 2014 Aug; 16(8):1196. PubMed ID: 25074973
    [No Abstract]   [Full Text] [Related]  

  • 14. Safety and efficacy of strategic implantable cardioverter-defibrillator programming to reduce the shock delivery burden in a primary prevention patient population.
    Buber J; Luria D; Gurevitz O; Bar-Lev D; Eldar M; Glikson M
    Europace; 2014 Feb; 16(2):227-34. PubMed ID: 24108231
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combining shock reduction strategies to enhance ICD therapy: a role for computer modeling.
    Volosin KJ; Exner DV; Wathen MS; Sherfesee L; Scinicariello AP; Gillberg JM
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):280-9. PubMed ID: 20958831
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Saving lives and reducing inappropriate device therapy: the MADIT family of implantable cardioverter-defibrillator and cardiac resynchronization therapy trials.
    Moss AJ
    Cardiol J; 2013; 20(3):217-9. PubMed ID: 23788293
    [No Abstract]   [Full Text] [Related]  

  • 17. Implantable cardioverter defibrillator therapy in paediatric practice: a single-centre UK experience with focus on subcutaneous defibrillation.
    Griksaitis MJ; Rosengarten JA; Gnanapragasam JP; Haw MP; Morgan JM
    Europace; 2013 Apr; 15(4):523-30. PubMed ID: 23333943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Recurrent AICD shocks in a 60-year-old man.
    Yeo C; Wong KC
    Heart; 2016 Aug; 102(16):1295. PubMed ID: 26980721
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Decline of defibrillation testing in the clinical practice: an 8-year nation-wide assessment.
    Brignole M; Occhetta E; Grazia Bongiorni M; Proclemer A; Favale S; Gasparini M; Accardi F; Valsecchi S
    Europace; 2014 Aug; 16(8):1103-4. PubMed ID: 24895021
    [No Abstract]   [Full Text] [Related]  

  • 20. Audible alert protected patient from inappropriate cardiac-defibrillator shocks.
    Bissinger A; Szoltek K; Lubinski A
    Cardiol J; 2017; 24(3):338-339. PubMed ID: 28660999
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 10.