BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 25142743)

  • 1. Modulation transfer function measurement of CT images by use of a circular edge method with a logistic curve-fitting technique.
    Takenaga T; Katsuragawa S; Goto M; Hatemura M; Uchiyama Y; Shiraishi J
    Radiol Phys Technol; 2015 Jan; 8(1):53-9. PubMed ID: 25142743
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A pitfall of using the circular-edge technique with image averaging for spatial resolution measurement in iteratively reconstructed CT images.
    Narita A; Ohkubo M
    J Appl Clin Med Phys; 2020 Feb; 21(2):144-151. PubMed ID: 31957969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images.
    Anam C; Fujibuchi T; Budi WS; Haryanto F; Dougherty G
    J Appl Clin Med Phys; 2018 Nov; 19(6):244-252. PubMed ID: 30338920
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions.
    Brunner CC; Stern SH; Minniti R; Parry MI; Skopec M; Chakrabarti K
    Med Phys; 2013 Aug; 40(8):081917. PubMed ID: 23927331
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms.
    Richard S; Husarik DB; Yadava G; Murphy SN; Samei E
    Med Phys; 2012 Jul; 39(7):4115-22. PubMed ID: 22830744
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom.
    Friedman SN; Fung GS; Siewerdsen JH; Tsui BM
    Med Phys; 2013 May; 40(5):051907. PubMed ID: 23635277
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noise-resolution tradeoffs in x-ray CT imaging: a comparison of penalized alternating minimization and filtered backprojection algorithms.
    Evans JD; Politte DG; Whiting BR; O'Sullivan JA; Williamson JF
    Med Phys; 2011 Mar; 38(3):1444-58. PubMed ID: 21520856
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Deriving the modulation transfer function of CT from extremely noisy edge profiles.
    Mori I; Machida Y
    Radiol Phys Technol; 2009 Jan; 2(1):22-32. PubMed ID: 20821125
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Techniques to improve the accuracy of presampling MTF measurement in digital X-ray imaging based on constrained spline regression.
    Zhou Z; Zhu Q; Zhao H; Zhang L; Ma W; Gao F
    IEEE Trans Biomed Eng; 2014 Apr; 61(4):1339-49. PubMed ID: 24658257
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Accuracy of Modulation Transfer Function for Target Size and Field of View in a Circular Edge Strategy Using the CT Image Measurement Program].
    Fukunaga M; Onishi H; Matsutomo N; Yamamoto H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2016 Jun; 72(6):489-95. PubMed ID: 27320152
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of noise on MTF calculations using different phantoms.
    González-López A
    Med Phys; 2018 May; 45(5):1889-1898. PubMed ID: 29500817
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of nonlinear three-dimensional optimized reconstruction algorithm filter on image quality and radiation dose: validation on phantoms.
    Bai M; Chen J; Raupach R; Suess C; Tao Y; Peng M
    Med Phys; 2009 Jan; 36(1):95-7. PubMed ID: 19235377
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accurate MTF measurement in digital radiography using noise response.
    Kuhls-Gilcrist A; Jain A; Bednarek DR; Hoffmann KR; Rudin S
    Med Phys; 2010 Feb; 37(2):724-35. PubMed ID: 20229882
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics.
    Higaki T; Nakamura Y; Zhou J; Yu Z; Nemoto T; Tatsugami F; Awai K
    Acad Radiol; 2020 Jan; 27(1):82-87. PubMed ID: 31818389
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Image quality of conventional images of dual-layer SPECTRAL CT: A phantom study.
    van Ommen F; Bennink E; Vlassenbroek A; Dankbaar JW; Schilham AMR; Viergever MA; de Jong HWAM
    Med Phys; 2018 Jul; 45(7):3031-3042. PubMed ID: 29749624
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validation of MTF measurement for digital mammography quality control.
    Carton AK; Vandenbroucke D; Struye L; Maidment AD; Kao YH; Albert M; Bosmans H; Marchal G
    Med Phys; 2005 Jun; 32(6):1684-95. PubMed ID: 16013727
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adaptive nonlocal means filtering based on local noise level for CT denoising.
    Li Z; Yu L; Trzasko JD; Lake DS; Blezek DJ; Fletcher JG; McCollough CH; Manduca A
    Med Phys; 2014 Jan; 41(1):011908. PubMed ID: 24387516
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology.
    Price RG; Vance S; Cattaneo R; Schultz L; Elshaikh MA; Chetty IJ; Glide-Hurst CK
    Med Phys; 2014 Aug; 41(8):081907. PubMed ID: 25086538
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of focal spot blooming on high-contrast spatial resolution in CT imaging.
    Grimes J; Duan X; Yu L; Halaweish AF; Haag N; Leng S; McCollough C
    Med Phys; 2015 Oct; 42(10):6011-20. PubMed ID: 26429276
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of adaptive statistical iterative reconstruction algorithm for dose reduction in CT: A pediatric oncology perspective.
    Brady SL; Yee BS; Kaufman RA
    Med Phys; 2012 Sep; 39(9):5520-31. PubMed ID: 22957619
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.