These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

404 related articles for article (PubMed ID: 25146030)

  • 21. Micro-Computed Tomographic Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals.
    da Silva Limoeiro AG; Dos Santos AH; De Martin AS; Kato AS; Fontana CE; Gavini G; Freire LG; da Silveira Bueno CE
    J Endod; 2016 Mar; 42(3):496-9. PubMed ID: 26776939
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Micro-computed tomography study of oval-shaped canals prepared with the self-adjusting file, Reciproc, WaveOne, and ProTaper universal systems.
    Versiani MA; Leoni GB; Steier L; De-Deus G; Tassani S; Pécora JD; de Sousa-Neto MD
    J Endod; 2013 Aug; 39(8):1060-6. PubMed ID: 23880278
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Micro-computed Tomography Assessment of Dentinal Micro-cracks after Root Canal Preparation with TRUShape and Self-adjusting File Systems.
    Zuolo ML; De-Deus G; Belladonna FG; Silva EJ; Lopes RT; Souza EM; Versiani MA; Zaia AA
    J Endod; 2017 Apr; 43(4):619-622. PubMed ID: 28216274
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Efficacy of 2 reciprocating systems compared with a rotary retreatment system for gutta-percha removal.
    Rios Mde A; Villela AM; Cunha RS; Velasco RC; De Martin AS; Kato AS; Bueno CE
    J Endod; 2014 Apr; 40(4):543-6. PubMed ID: 24666908
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths.
    Liu R; Kaiwar A; Shemesh H; Wesselink PR; Hou B; Wu MK
    J Endod; 2013 Jan; 39(1):129-32. PubMed ID: 23228272
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Efficacy of Combined Use of Different Nickel-Titanium Files on Removing Root Canal Filling Materials.
    Yürüker S; Görduysus M; Küçükkaya S; Uzunoğlu E; Ilgın C; Gülen O; Tuncel B; Görduysus MÖ
    J Endod; 2016 Mar; 42(3):487-92. PubMed ID: 26778268
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Formation of dentinal microcracks after root canal preparation with four kinds of mechanical nickel-titanium files.
    Wang Z; Xue M
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2024 Feb; 42(1):75-81. PubMed ID: 38475954
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Incidence of dentinal defects after root canal preparation: reciprocating versus rotary instrumentation.
    Bürklein S; Tsotsis P; Schäfer E
    J Endod; 2013 Apr; 39(4):501-4. PubMed ID: 23522545
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems.
    Liu W; Wu B
    J Endod; 2016 Feb; 42(2):299-303. PubMed ID: 26686822
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Root Canal Preparation Does Not Induce Dentinal Microcracks In Vivo.
    PradeepKumar AR; Shemesh H; Archana D; Versiani MA; Sousa-Neto MD; Leoni GB; Silva-Sousa YTC; Kishen A
    J Endod; 2019 Oct; 45(10):1258-1264. PubMed ID: 31421915
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of altering the reciprocation range on the fatigue life and the shaping ability of WaveOne nickel-titanium instruments.
    Saber Sel D; Abu El Sadat SM
    J Endod; 2013 May; 39(5):685-8. PubMed ID: 23611391
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin.
    Capar ID; Arslan H; Akcay M; Uysal B
    J Endod; 2014 Sep; 40(9):1482-4. PubMed ID: 25146038
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Occurrence of Dentinal Microcracks in Severely Curved Root Canals with ProTaper Universal, WaveOne, and ProTaper Next File Systems.
    Li SH; Lu Y; Song D; Zhou X; Zheng QH; Gao Y; Huang DM
    J Endod; 2015 Nov; 41(11):1875-9. PubMed ID: 26386948
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of ultrasonic removal of fractured files from the middle third of root canals on dentinal cracks: a micro-computed tomography study.
    Fu M; Huang X; He W; Hou B
    Int Endod J; 2018 Sep; 51(9):1037-1046. PubMed ID: 29432650
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Dentinal Microcrack Development after Canal Preparation: A Longitudinal in Situ Micro-computed Tomography Study Using a Cadaver Model.
    De-Deus G; César de Azevedo Carvalhal J; Belladonna FG; Silva EJNL; Lopes RT; Moreira Filho RE; Souza EM; Provenzano JC; Versiani MA
    J Endod; 2017 Sep; 43(9):1553-1558. PubMed ID: 28735793
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The influence of different angles and reciprocation on the shaping ability of two nickel-titanium rotary root canal instruments.
    Al-Sudani D; Kaabi H; Al Gamdi A; Al Dakheel A
    J Contemp Dent Pract; 2014 Jul; 15(4):451-5. PubMed ID: 25576112
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of Reciproc blue, XP-endo shaper, and WaveOne gold instruments on dentinal microcrack formation: A micro-computed tomographic evaluation.
    Uğur Aydın Z; Keskin NB; Özyürek T
    Microsc Res Tech; 2019 Jun; 82(6):856-860. PubMed ID: 30729608
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A micro-computed tomography evaluation of long-oval canal preparation using reciprocating or rotary systems.
    Busquim S; Cunha RS; Freire L; Gavini G; Machado ME; Santos M
    Int Endod J; 2015 Oct; 48(10):1001-6. PubMed ID: 25314154
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of XP-endo Shaper, Reciproc Blue, and ProTaper Universal NiTi Systems on Dentinal Microcrack Formation Using Micro-Computed Tomography.
    Aksoy Ç; Keriş EY; Yaman SD; Ocak M; Geneci F; Çelik HH
    J Endod; 2019 Mar; 45(3):338-342. PubMed ID: 30803543
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The effect of larger apical preparations in the danger zone of lower molars prepared using the Mtwo and Reciproc systems.
    Sant'Anna Júnior A; Cavenago BC; Ordinola-Zapata R; De-Deus G; Bramante CM; Duarte MA
    J Endod; 2014 Nov; 40(11):1855-9. PubMed ID: 25127935
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.