BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 25146849)

  • 1. Multiplexing strategies for monolithic crystal PET detector modules.
    Pierce LA; Hunter WC; Haynor DR; MacDonald LR; Kinahan PE; Miyaoka RS
    Phys Med Biol; 2014 Sep; 59(18):5347-60. PubMed ID: 25146849
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of highly multiplexed monolithic PET / gamma camera detector modules.
    Pierce LA; Pedemonte S; DeWitt D; MacDonald L; Hunter WCJ; Van Leemput K; Miyaoka R
    Phys Med Biol; 2018 Mar; 63(7):075017. PubMed ID: 29498361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation.
    Borghi G; Tabacchini V; Schaart DR
    Phys Med Biol; 2016 Jul; 61(13):4904-28. PubMed ID: 27285955
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A thick semi-monolithic scintillator detector for clinical PET scanners.
    Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z
    Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Resolution Properties of a Prototype Continuous Miniature Crystal Element (cMiCE) Scanner.
    Miyaoka RS; Li X; Hunter W; Pierce LA; McDougald W; Kinahan PE; Lewellen TK
    IEEE Trans Nucl Sci; 2011 Oct; 58(5):. PubMed ID: 24347676
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method.
    Zeng X; Zhang Z; Li D; Huang X; Wang Z; Wang Y; Zhou W; Wang P; Zhu M; Wei Q; Gong H; Wei L
    Phys Med Biol; 2024 Apr; 69(8):. PubMed ID: 38484392
    [No Abstract]   [Full Text] [Related]  

  • 8. Optical simulation study on the spatial resolution of a thick monolithic PET detector.
    Stockhoff M; Van Holen R; Vandenberghe S
    Phys Med Biol; 2019 Sep; 64(19):195003. PubMed ID: 31416055
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optical delay encoding for fast timing and detector signal multiplexing in PET.
    Grant AM; Levin CS
    Med Phys; 2015 Aug; 42(8):4526-35. PubMed ID: 26233181
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance of a SiPM based semi-monolithic scintillator PET detector.
    Zhang X; Wang X; Ren N; Kuang Z; Deng X; Fu X; Wu S; Sang Z; Hu Z; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2017 Sep; 62(19):7889-7904. PubMed ID: 28858853
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setup.
    Borghi G; Tabacchini V; Bakker R; Schaart DR
    Phys Med Biol; 2018 Jul; 63(15):155006. PubMed ID: 29995639
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A 32 mm  ×  32 mm  ×  22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI.
    Borghi G; Peet BJ; Tabacchini V; Schaart DR
    Phys Med Biol; 2016 Jul; 61(13):4929-49. PubMed ID: 27286232
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Basic performance of a large area PET detector with a monolithic scintillator.
    Yoshida E; Inadama N; Osada H; Kawai H; Nishikido F; Murayama H; Tsuda T; Yamaya T
    Radiol Phys Technol; 2011 Jul; 4(2):134-9. PubMed ID: 21340540
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution monolithic LYSO detector with 6-layer depth-of-interaction for clinical PET.
    Stockhoff M; Decuyper M; Van Holen R; Vandenberghe S
    Phys Med Biol; 2021 Jul; 66(15):. PubMed ID: 34261049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system.
    Marcinkowski R; Mollet P; Van Holen R; Vandenberghe S
    Phys Med Biol; 2016 Mar; 61(5):2196-2212. PubMed ID: 26907952
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence.
    Maas MC; van der Laan DJ; van Eijk CW; Schaart DR; Beekman FJ; Bruyndonckx P; Lemaître C
    Med Phys; 2010 Apr; 37(4):1904-13. PubMed ID: 20443512
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Depth of interaction determination in monolithic scintillator with double side SiPM readout.
    Morrocchi M; Ambrosi G; Bisogni MG; Bosi F; Boretto M; Cerello P; Ionica M; Liu B; Pennazio F; Piliero MA; Pirrone G; Postolache V; Wheadon R; Del Guerra A
    EJNMMI Phys; 2017 Dec; 4(1):11. PubMed ID: 28211032
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New Continuous Miniature Crystal Element (cMiCE) Detector Geometries.
    Miyaoka RS; Li X; Lockhart C; Lewellen TK
    IEEE Nucl Sci Symp Conf Rec (1997); 2009 Oct; 2009():3639-3642. PubMed ID: 20625465
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Study of PET Detector Performance with Varying SiPM Parameters and Readout Schemes.
    Li X; Lockhart C; Lewellen TK; Miyaoka RS
    IEEE Trans Nucl Sci; 2011; 58(3):590-596. PubMed ID: 22685348
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.