211 related articles for article (PubMed ID: 25157579)
1. Implementation of a triple Gaussian beam model with subdivision and redefinition against density heterogeneities in treatment planning for scanned carbon-ion radiotherapy.
Inaniwa T; Kanematsu N; Hara Y; Furukawa T; Fukahori M; Nakao M; Shirai T
Phys Med Biol; 2014 Sep; 59(18):5361-86. PubMed ID: 25157579
[TBL] [Abstract][Full Text] [Related]
2. A trichrome beam model for biological dose calculation in scanned carbon-ion radiotherapy treatment planning.
Inaniwa T; Kanematsu N
Phys Med Biol; 2015 Jan; 60(1):437-51. PubMed ID: 25658007
[TBL] [Abstract][Full Text] [Related]
3. Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance.
Ali I; Ahmad S
Med Dosim; 2013; 38(3):255-61. PubMed ID: 23558145
[TBL] [Abstract][Full Text] [Related]
4. A novel pencil beam model for carbon-ion dose calculation derived from Monte Carlo simulations.
Zhang H; Dai Z; Liu X; Chen W; Ma Y; He P; Dai T; Shen G; Yuan P; Li Q
Phys Med; 2018 Nov; 55():15-24. PubMed ID: 30471815
[TBL] [Abstract][Full Text] [Related]
5. Nuclear-interaction correction of integrated depth dose in carbon-ion radiotherapy treatment planning.
Inaniwa T; Kanematsu N; Hara Y; Furukawa T
Phys Med Biol; 2015 Jan; 60(1):421-35. PubMed ID: 25658006
[TBL] [Abstract][Full Text] [Related]
6. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
[TBL] [Abstract][Full Text] [Related]
7. Application of the electron pencil beam redefinition algorithm to electron arc therapy.
Chi PC; Hogstrom KR; Starkschall G; Boyd RA; Tucker SL; Antolak JA
Med Phys; 2006 Jul; 33(7):2369-83. PubMed ID: 16898439
[TBL] [Abstract][Full Text] [Related]
8. Monte Carlo-based parametrization of the lateral dose spread for clinical treatment planning of scanned proton and carbon ion beams.
Parodi K; Mairani A; Sommerer F
J Radiat Res; 2013 Jul; 54 Suppl 1(Suppl 1):i91-6. PubMed ID: 23824133
[TBL] [Abstract][Full Text] [Related]
9. Pencil-beam redefinition algorithm for electron dose distributions.
Shiu AS; Hogstrom KR
Med Phys; 1991; 18(1):7-18. PubMed ID: 2008174
[TBL] [Abstract][Full Text] [Related]
10. Experimental verification of a non-invasive method to monitor the lateral pencil beam position in an anthropomorphic phantom for carbon-ion radiotherapy.
Félix-Bautista R; Gehrke T; Ghesquière-Diérickx L; Reimold M; Amato C; Turecek D; Jakubek J; Ellerbrock M; Martišíková M
Phys Med Biol; 2019 Sep; 64(17):175019. PubMed ID: 31239428
[TBL] [Abstract][Full Text] [Related]
11. Application of an inverse kernel concept to Monte Carlo based IMRT.
Bogner L; Hartmann M; Rickhey M; Moravek Z
Med Phys; 2006 Dec; 33(12):4749-57. PubMed ID: 17278828
[TBL] [Abstract][Full Text] [Related]
12. Validation and testing of a novel pencil-beam model derived from Monte Carlo simulations in carbon-ion treatment planning for different scenarios.
Zhang H; Li Q; Liu X; Ma Y; He P; Shen G; Li Z; Chen W; Niu R; Dai Z; Xiao G
Phys Med; 2022 Jul; 99():1-9. PubMed ID: 35576855
[TBL] [Abstract][Full Text] [Related]
13. Dynamic splitting of Gaussian pencil beams in heterogeneity-correction algorithms for radiotherapy with heavy charged particles.
Kanematsu N; Komori M; Yonai S; Ishizaki A
Phys Med Biol; 2009 Apr; 54(7):2015-27. PubMed ID: 19287085
[TBL] [Abstract][Full Text] [Related]
14. Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams.
Mizutani S; Takada Y; Kohno R; Hotta K; Tansho R; Akimoto T
J Appl Clin Med Phys; 2016 Mar; 17(2):315-327. PubMed ID: 27074456
[TBL] [Abstract][Full Text] [Related]
15. Experimental characterization of lateral profiles of scanned proton and carbon ion pencil beams for improved beam models in ion therapy treatment planning.
Schwaab J; Brons S; Fieres J; Parodi K
Phys Med Biol; 2011 Dec; 56(24):7813-27. PubMed ID: 22112370
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of the influence of double and triple Gaussian proton kernel models on accuracy of dose calculations for spot scanning technique.
Hirayama S; Takayanagi T; Fujii Y; Fujimoto R; Fujitaka S; Umezawa M; Nagamine Y; Hosaka M; Yasui K; Omachi C; Toshito T
Med Phys; 2016 Mar; 43(3):1437-50. PubMed ID: 26936728
[TBL] [Abstract][Full Text] [Related]
17. Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans.
Bazalova-Carter M; Qu B; Palma B; Hårdemark B; Hynning E; Jensen C; Maxim PG; Loo BW
Med Phys; 2015 May; 42(5):2615-25. PubMed ID: 25979053
[TBL] [Abstract][Full Text] [Related]
18. A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.
Westerly DC; Mo X; Tomé WA; Mackie TR; DeLuca PM
Med Phys; 2013 Jun; 40(6):061706. PubMed ID: 23718585
[TBL] [Abstract][Full Text] [Related]
19. A pencil beam algorithm for helium ion beam therapy.
Fuchs H; Strobele J; Schreiner T; Hirtl A; Georg D
Med Phys; 2012 Nov; 39(11):6726-37. PubMed ID: 23127066
[TBL] [Abstract][Full Text] [Related]
20. Three-dimensional electron dose calculation using an improved hybrid pencil beam model.
Chengjun G; Zhangwen W; Zhengming L; Jette D
Med Phys; 2003 Mar; 30(3):415-23. PubMed ID: 12674242
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]